EYC DST01 Bedienungsanleitung

Operation-Manual
eYc DST01 Universal Isolation Signal Converter / Splitter
eYc DST01

www.eyc-tech.com
‧‧‧
2
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
Warning Symbol
This document contains notices that you should observe to ensure your own personal safety, as well
as to protect the product and connected equipment. These notices are highlighted in the manual by a
warning triangle and are marked as follows.
The danger symbol indicates that death or severe personal injury may result if proper
precautions are not taken. Do not proceed beyond a warning symbol until the indicated conditions are fully
understood and met.
Preface
Original equipment manufacturer reserves the right to change information available in this document
without notice. The manufacturer is not liable for any damages incurred to equipment/personal during
installation or use of equipment as explained in this document. User must acquire sufficient knowledge &
skills prior to using equipment in the application and follow all the local standards & regulations to meet
safety requirements.

www.eyc-tech.com
‧‧‧
3
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
Table of Contents
1. Introduction ........................................................................................ 4
1.1 Introduction ......................................................................................... 4
1.2 Features ............................................................................................. 4
1.3 Programming Port .............................................................................. 5
1.4 Display Board Keys ............................................................................ 6
1.5 Menu Flowchart .................................................................................. 8
1.6 Parameter Availability Table ............................................................... 12
2. Installation and Wiring ....................................................................... 15
2.1 Unpacking .......................................................................................... 15
2.2 Dimension .......................................................................................... 16
2.3 Wiring ................................................................................................. 17
3. Programming ...................................................................................... 22
3.1 User Security ...................................................................................... 22
3.2 Calibration Password .......................................................................... 22
3.3 Signal Input ........................................................................................ 22
3.4 Output Type ........................................................................................ 23
3.5 Retransmission ................................................................................... 23
3.6 Zero and Span Adjustment ................................................................. 23
3.7 Square Root Function(SQRT) ............................................................ 23
3.8 User Calibration .................................................................................. 24
3.9 Digital Filter ........................................................................................ 25
3.10 Manual Control ................................................................................... 25
3.11 Factory Default ................................................................................... 25
3.12 Data Communication .......................................................................... 25
3.13 Digital Input ........................................................................................ 26
4. Calibration ........................................................................................... 27
4.1 Equipment Required Before Calibration ............................................. 27
5. Communication .................................................................................. 30
5.1 Functions Supported .......................................................................... 30
5.2 Exception Responses ......................................................................... 31
5.3 Error Code .......................................................................................... 32
5.4 Mode .................................................................................................. 32
5.5 PROG Code ....................................................................................... 32
5.6 Scaling ................................................................................................ 33
5.7 Data Conversion ................................................................................. 33
5.8 Communication Examples .................................................................. 33

www.eyc-tech.com
‧‧‧
4
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
1. Introduction
1.1 Introduction
DST01 The signal conditioner incorporates two bright and easy to read LCD displays which
indicate process value(PV) and user selected parameter.
Powered by a DC 12 ... 38 V or AC 95 ... 250 V supply. It is fully programmable for linear
voltage, linear current, Pt100 and thermocouple types such as J, K, T, E, B, R, S, N, L, U, P, C, and
D input. Its fast sampling rate allows the signal conditioner to retransmit the signal faster, the
maximum of 3 retransmission with one input.
1.2 Features
Signal isolation:Power supply;Analog input
3 groups of analog output
1 set RS-485 output
Multiple input signals
LED display working status
Easy button operation planning
DIN rail installation, high safety & stability

www.eyc-tech.com
‧‧‧
5
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
1.3 Programming Port
A Micro USB programming port is available for automatic configuration, calibration and
firmware upgrades without the need to access the keys on the front panel.
Front Panel
Micro USB Programming Port
Terminals
Lockout Protection
According to user security requirements, one of four lockout levels(NONE, ALL, USER, SET) can
be selected to prevent certain settings from being changed.
Digital Filter
A first-order low-pass filter with a programmable time constant is used to improve the stability of the
process value(PV). This is particularly useful in certain applications where the process value is too
unstable to be read
Event Input
Event Input is available as an option to change certain function.
Analog Retransmission
This signal conditioner can do a maximum of 3 analog retransmission with one input.
Bidirectional Menu Navigation
This controller has bidirectional menu navigation. This will allow the user to access previous menu
settings easily by using keys.
SQRT Function
The signal conditioner is having PV SQRT function

www.eyc-tech.com
‧‧‧
6
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
1.4 Display Board Keys
There are 4 Keys available in the display board for the user to operate as explained
below.
1. SCROLL KEY or ENTER KEY:
This key is used to select a parameter to be viewed or adjusted.
2. UP KEY:
This key is used to increase the value of the selected parameter.
3. DOWN KEY:
This key is used to decrease the value of the selected parameter.
4. RESET KEY:
This key is used to:
1. Revert the display to the home screen.
2. Reset a latching alarm once the alarm condition is removed.
3. Stop manual control mode, auto-tuning mode or calibration mode.
4. Clear an auto-tuning or communication error message.
5. Restart the dwell timer when the dwell timer has timed out.
6. Enter the manual control menu if the failure mode occurs.
ENTER KEY:Press and hold for 5 seconds or longer to:
1. Enter the setup menu. The display will show
2. Enter the manual control mode. The display will show
3. Enter the auto-tuning mode. The display will show
4. Perform calibration of a selected parameter during the calibration procedure
Press and hold for 6.2 seconds, then let go to select manual control mode.
Press and hold for 7.4 seconds, then let go to select auto-tuning mode.
Press and hold for 8.6 seconds, then let go to select calibration mode.
During power-up, the upper display will show PROG and the lower display will show the
Firmware version for 6 seconds.

www.eyc-tech.com
‧‧‧
8
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
1.5 Menu Flowchart
The Menu has been divided into 5 groups. They are as follows:
Basic Menu
Output Menu(oUt)
Communication Menu(CoMM)
Manual Mode Menu(MANU)
Calibration Menu(CALI)
(1) Basic Menu
Use
or
key to get bASE in the lower display then use key to enter
to
Base menu parameters.
INPT
UNIT
dP
INLO
INHI
FILT
dISP
L.CUT
SQRt
dI
oFt.L
CA.Lo
oFt.H
CA.HI
CodE
LoCK
oFS1
oFS2
bASE
FILE
PV,MV
PASS=CODE
CALI
MANU
CoMM
oUt
PASS=CODE

www.eyc-tech.com
‧‧‧
9
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
(2) Output Menu (oUt)
Use
or
key to get oUT in the lower display then use key to enter to output
menu parameters.
PASS=CODE
PASS=CODE
O1TY
ANL1
ANH1
otZ1
otS1
O2TY
ANL2
ANH2
otZ2
otS2
O3TY
ANL3
ANH3
otZ3
otS3
FILE
PV,MV
bASE
CALI
MANU
CoMM
oUt

www.eyc-tech.com
‧‧‧
10
DST01 Universal Isolation Signal Converter / Splitter
DST01 Signal / Meter
PASS=CODE
PASS=CODE
FILE
PV,MV
bASE
CALI
MANU
CoMM
oUt
(3) Communication Menu (CoMM)
Use
or
key to get CoMM in the lower display then use key to enter
into
communication menu parameters.
AddR
bAUd
dAtA
PARI
StoP
Inhaltsverzeichnis