1110
VP55/VP85 Protection
1. Ensure clean oil is added to a level within the FILL ZONE.
2. Do not use to remove refrigerant from a system. Use a recovery
machine and filter to remove refrigerant and particles from the
system before usingVP55/VP85 to evacuate the system.
3. Do not use on pressurized systems. Doing so may damage or
contaminate your vacuum pump.
4. Do not use on ammonia or salt water systems. Doing so may
damage or contaminate your vacuum pump.
5. Store with ports capped to prevent dust from entering.
6. Drain oil after every job and store VP55/VP85 empty to prevent
spillage and reduced oil life.
Setup
1. Inspect the machine and repair any damaged parts before using.
2. Ensure motor power switch is turned OFF (down) before
connecting or disconnecting power.
3. Ensure power cord is not damaged.
4. Ensure all equipment is grounded.
5. Extension cord options:
14 AWG or thicker, up to 50 feet (15 m)
DO NOT USE 18 AWG!
NOTICE: Risk of Property Damage.The use of an undersized
extension cord will cause voltage to drop resulting in power loss
to the motor and overheating.
6. Ensure extension cord is grounded, 3 conductor, and is not
damaged.
Grounding Instructions
This product must be grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current. This product is equipped with a
cord having a grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
WARNING – Improper installation of the grounding plug is able to
result in a risk of electric shock. When repair or replacement of the cord
or plug is required, do not connect the grounding wire to either flat
blade terminal.The wire with insulation having an outer surface that is
green with or without yellow stripes is the grounding wire.
Check with a qualified electrician or serviceman when the
grounding instructions are not completely understood, or when in
doubt as to whether the product is properly grounded. Do not modify
the plug provided; if it does not fit the outlet, have the proper outlet
installed by a qualified electrician.