Option 24.1 -24.3 Priority Number(s) LV1 126
Option 24.4 – Lead OFF Time LV1 126
Option 24.5 – Lead (master) Boiler Select Method LV1 126
Option 24.6 – lag (slave) On Rate (0-100%) LV1 127
Option 24.7 – lag (slave) On Delay (0-999 minutes) LV1 127
Option 24.8 – lag (slave) O Rate (0-100%) LV3 127
Option 24.9 – lag (slave) O Delay (0-999 minutes) LV3 127
Option 25.0 – Banking based on temperature / water temperature standby or steam boiler
LV3 127
Option 25.1 – Water temperature zero value LV3 128
Option 25.2 – Water temperature span value LV3 128
Option 25.3 – Water temperature cut-in LV1 128
Option 25.4 – Water temperature cut-out LV1 128
Option 25.5 – Temperature based warming limit LV1 128
Option 25.6 – Lag wait time LV1 128
Option 28.0 – Analog Input 1 decimals (0-2) LV3 128
Option 28.1 – Analog Input 1 zero (0-999) LV3 128
Option 28.2 – Analog Input 1 span (0-999) LV3 128
Option 28.3 – Analog Input 2 decimals (0-2) LV3 129
Option 28.4 – Analog Input 2 zero (0-999) LV3 129
Option 28.5 – Analog Input 2 span (0-999) LV3 129
Option 28.6 – Analog Input 3 decimals (0-2) LV3 129
Option 28.7 – Analog Input 3 zero (0-999) LV3 129
Option 28.8 – Analog Input 3 span (0-999) LV3 129
Option 29.0 – 4-20mA Output 1 unction i not VSD LV3 129
Option 29.1 – Output1 zero value (4mA output) LV3 130
Option 29.2 – Output1 span value (20mA output) LV3 130
Option 29.3 – 4-20mA Output 2 unction i not VSD LV3 130
Option 29.4 – Output2 zero value (4mA output) LV3 130
Option 29.5 – Output2 span value (20mA output) LV3 130
Option 29.6 – 4-20mA Output 3 unction i not VSD LV3 130
Option 29.7 – Output3 zero value (4mA output) LV3 130
Option 29.8 – Output3 span value (20mA output) LV3 131
Option 30.0 – Oxygen probe inter ace serial number LV3 133
Option 30.1 - Oxygen probe calibration o set value (0 – 999) LV3 133
Option 30.2 - Oxygen probe calibration gain value (0 – 999) LV3 133
Option 30.4 – Flue and inlet sensor temperature units (0 – 1) LV3 134
Option 30.5 - Oxygen input unction (0/1) LV3 134
Option 30.6 - Oxygen probe calibrate enable (0 – 2) LV3 134
Option 30.7 - Boiler transport delay (5 – 60 seconds) LV3 135
Option 30.8 - Reset oxygen trim pro ile (0/1) LV3 135
Option 30.9 – Automatic trim commissioning (0 / 1) LV3 135
Options 31.1 to 31.4 - Trim Type or pro iles 1 to 4 (0 to 2) LV3 137
Option 32.0 - Trim limit de ault (0/1) LV3 138
Options 33.1 to 33.4 - Trim integral gain (De ault 10%) LV3 138
Option 34.0 - Trim proportional gain (0/1) LV3 139
Options 34.1 to 34.4 - Trim proportional gain (0.0 – 99.9%) LV3 139
Option 34.5 - Calculating and entering the low values manually LV3 139
Option 35.0 – Inlet temperature sensor serial number LV3 142
Options 35.5 to 35.8-Calori ic values o uels/pro iles 1 to 4 respectively (0.0 – 99.9) LV3 142
Option 35.9 - Boiler radiated heat loss (0.0 – 9.9%) LV3 143
Option 36.0 - Flue temperature alarm select (0/1) LV3 143
Options 36.1 to 36.4 - Flue temperature low alarm values (0 – 999) LV3 143
Option 38.0 - Oxygen alarm select (0 – 2) LV3 144
Options 38.1 to 38.4 - Oxygen low alarm values at low ire (0.0 – 99.9%) LV3 144
Options 39.1 to 39.4 - Oxygen low alarm values at high ire (0.0 – 99.9%) LV3 144