Fisher F-ERVXQ-D200 Bedienungsanleitung

Models:
F-ERVXQ-D200
F-ERVXQ-D300
F-ERVXQ-D400
Attention
Please read this manual carefully before using the equipment. For safety precautions,
please read carefully before construction or use, and use the equipment safely.
Technical Manual
Energy Recovery Ventilator
Models:
F-ERVXQ-D600
F-ERVXQ-D800
F-ERVXQ-D1000
mepokerkft.hu

Safety Considerations-----------------------------------------------------------3-4
Unit Specifications-----------------------------------------------------------------5
Dimension--------------------------------------------------------------------------6
Installation Considerations----------------------------------------------------7-10
Electrical Installation----------------------------------------------------------11-12
Precautions for use---------------------------------------------------------------13
Controller Instructions--------------------------------------------------------14-21
Maintenance-----------------------------------------------------------------------22
Failure diagnosis------------------------------------------------------------------22
Contents
mepokerkft.hu

Please read the following safety instructions before installation. And ensure that the unit is installed
correctly.
Please observe all instruction in order to avoid any injury or damage to equipment or property.
The following symbols indicate potential levels of caution.
Situations with a risk or death or
serious injure. Situations with a risk of injury or
equipment/property damage.
The following symbols indicate compliance which must be observed
Not allowed or Stop Must follow or obliged
Safety attentions
Installation to be carried out by qualified
person, End Users must not install, move or
re-install this equipment by themselves
An anti-bird net or similar device should be
installed to outside vents. Ensure there are
no obstructions to or in the ducts
Installation engineers must follow this man-
ual strictly. Improper action can create a
health hazard and reduce efficiency of the
unit
Fresh air vent must be far enough away
from any flue gas discharge or areas where
hazardous vapors are present
Unit must be installed strictly following this
manual and mounted to a weight bearing
surface for the weight of the unit
Electric engineering must follow national
regulations and the manual, use special ca-
bles. Less capacity cables and improper en-
gineering can cause electric shock or fire.
During maintenance or repair, the unit and
circuit breaker must be switched off. Other-
wise electric shock could occur.
Ground wire cannot be connected to gas
pipe, water pipe, lighting rod or telephone
line etc. Incorrect grounding can cause
electric shock.
3
Safety Considerations
mepokerkft.hu

Do not install the unit in an extremely hu-
mid conditions, as it may result in electric
shock and pose a fire risk.
Do not use the units as the primary kitchen
extract grease and fatty deposits can block
the heat exchanger, filter and pose a fire
risk.
Don not install the unit in areas there any
poisonous or caustic gases are present.
Do not install the unit near open flame as it
may result in over heating and pose a fire
risk
Acidic or alkali environments can cause poi-
soning or a fire Rated supply voltage must be maintained,
otherwise this may cause fire.
Power cable and wires must be installed by
a qualified electrical engineer. Improper
connection can cause over heating. Fire and
loss of efficiency.
To avoid condensation, insulation should be
fitted to fresh air ducts. Other ducting may
also require insulation depending on dew
point conditions.
Insulation between the metal ducting and
wall penetration must be installed if the
ducting penetrates metal wall cladding, to
avoid risk of electric shock or current leak-
age.
The cover of wiring box must be pressed
down and closed to avoid dust and dirt en-
tering. Excess dust and dirt can cause over-
heating of terminals and result in fire or
electric shock.
Use only approved installation hardware
and accessories. Failure to observe can re-
sult in fire risk, electric shock and equip-
ment failure
Where the unit is positioned, at high level in
a hot humid situation. Please ensure suffi-
cient ventilation is available
The outdoor ducts must be installed facing
downwards to avoid rain water entering.
Improper installation can cause water leak-
age.
Correctly sized MCB must be fitted to the
unit suitable earth leakage protection
should also be installed to avoid risk of elec-
tric shock or fire.
4
Safety Considerations
mepokerkft.hu

Model F-ERVXQ-D200 F-ERVXQ-D300 F-ERVXQ-D400 F-ERVXQ-D600 F-ERVXQ-D800
Performance
Airflow(m3/h) 200 300 400 600 800
Airflow (l/s) 56 83 111 167 222
External pressure(Pa) 65 75 78 87 90
Enth. Eff
(%)
Cooling 55-66 57-70 57-70 59-74 55-66
Heating 59-70 61-72 60-74 61-78 57-76
Temp. Eff (%) 70-82 68-82 69-83 70-83 68-83
Noise Db(A) 31.5 34.5 37.5 39 41
Power Supply 220~240V/1Ph/50Hz
Input Power (W) 43 80 116 162 290
Power Cable 3x1.5mm2
Control Cable 2x0.5mm2
Control
Standard Yes (7-Day Time-clock)
(BMS)
Modbus Yes
Fan Type BLDC Fan Motors
Fan Speeds (Supply) 10 Speed Fan Control
Fan Speeds (Exhaust) 10 Speed Fan Control
Summer Bypass Yes (Automatic with adjustable range)
Defrost Yes (Automatic with adjustable range)
CO2 Control Optional sensor (On / Off control with adjustable range)
Fan Boost Contacts Yes (1x available connections to Volt-Free contacts: Close= boost to High Speed)
Fire Shutdown Yes (1x available connection to Volt-Free contacts: Closed = Shutdown)
Weight (Kg) 24.5 34.5 37.5 35 54
Size (WxHxD) (mm) 736*580*264 814*599*270 814*804*270 867*902*280 1134*884*388
Duct Size (mm) 150 150 150 200 250
F-ERVXQ-D1000
1000
278
76
58-70
62-75
70-83
42
327
62
1134*1134*388
250
5
Specifications
mepokerkft.hu

Electric
Box
EA
OA
EA
OA SA
RA RA
SA
Electric
Box
Model A B C E F G I K M N
F-ERVXQ-D200 580 736 100 795 510 19 290 20 264 Φ144
F-ERVXQ-D300 599 814 100 745 657 19 315 111 270 Φ144
F-ERVXQ-D400 804 814 100 745 860 19 480 111 270 Φ144
Dimensions
F-ERVXQ-D200 F-ERVXQ-D300
F-ERVXQ-D400
6
Dimensions
The access door
Electric
control
box
EA
OA RA
SA
The access door
Electric
control
box
EA
OA RA
SA
Model A B C D E F G L K M M1 M2 N
F-ERVXQ-D600 902 867 107 197 833.5 922 20.5 451.5 115.5 280 139.5
Φ194
F-ERVXQ-D800 884 1134 85 202 818 1189 20.5 378 128 388 194
Φ242
F-ERVXQ-D1000 1134 1134 85 202 1068 1189 20.5 628 128 388 194
Φ242
F-ERVXQ-D1300 1243 1193 85 241 1173 1248 20.5 629.5 133 388 191 241 Φ242
F-ERVXQ-D600
F-ERVXQ-D800
F-ERVXQ-D1000 F-ERVXQ-D1300
mepokerkft.hu

Installation Considerations
1.Protect the unit to avoid dust or other obstructions entering the unit and accessories during installa-
2. Be sure the ceiling height is no less than the Figures in above table B column.
B
F-ERVXQ-D200
F-ERVXQ-D600 ~ F-ERVXQ-D1300
F-ERVXQ-D300
F-ERVXQ-D400
A
450
450
RA
600
SA
EA OA
SERVICE PORT
A
450
450
RA
600
SA
EA OA
SERVICE PORT
F-ERVXQ-D200 F-ERVXQ-D300
F-ERVXQ-D400 F-ERVXQ-D600 ~ F-ERVXQ-D1300
Model A Inner ceiling height B
F-ERVXQ-D200 580 320
F-ERVXQ-D300 599 320
F-ERVXQ-D400 804 320
F-ERVXQ-D600 902 330
F-ERVXQ-D800 884 450
F-ERVXQ-D1000 1134 450
F-ERVXQ-D1300 1243 450
A
450
450
RA
600
SA
EA
OA
SERVICE PORT
7
Installation Considerations
mepokerkft.hu

Serve bends Multiple reducers/ crimped duct
Multiple direction changes
3. Unit must not be installed close to boiler flues.
4. Following phenomenon should be avoided in the ducting installation.
5. Excessive use of flex-duct and long flex-duct runs should be avoided.
6. Fire dampers must be fitted as per national and local fire regulations.
7. Unit must not be exposed to ambient temperature above 40℃ and should not face an open fire.
8. Take action to avoid dew and frost.
As shown by drawing below, unit will produce dew or frost when saturation curve is formed from A to C.
Use pre-heater to ensure conditions are kept to right of the curve (B to B',to move C to C) to prevent
condensation or frost formation.
9. To avoid the outdoor exhaust air cycling back to indoor, the distance between the two vents installed
on the outside wall should be over 1000mm.
10.If heater is equipped to the unit, operation of heater should be synchronous with the unit, so that the
heater starts to work only when unit starts.
11.Duct muffler may be considered if user wants indoor noise to be minimized.
8
Installation Considerations
mepokerkft.hu

Ducting
1. Connection of unit vents and ducts should be taped or sealed to prevent air leakage, and should
comply to relevant guidelines and regulations.
2. The two outdoor vents should face downward toward the outside to prevent any rain water ingress.
(angle 1/100 1/50).
3. Insulation must be with the two ducts outside to prevent condensation.
Material: glass cotton, Thickness: 25mm
坡度1/100-1/50
Gradient1/100-1/50
9
Installation Considerations
天花板吊装螺杆
(Φ10-Φ12)
螺母
垫圈
吊装部件
垫圈
螺母
Suspending screw pole
Nut
Gasket
Suspending Part
Gasket
Nut
Physical Installation
1.Installer to prepare suitable threaded hangers with adjustable nuts and gaskets.
2.Install as shown by the image above. Installation must be level and securely fastened.
3.Failure to observe proper fixing could result in injury, equipment damage and excessive vibration.
Uneven installation will also effect damper operation.
mepokerkft.hu

Installation Diagram
F-ERVXQ-D200
F-ERVXQ-D300
F-ERVXQ-D400
OA
Return Air
SA
Exhaust Duct
Supply Duct
RA
Supply Air
Return Duct
Outside Fresh Air Duct
insulation
Suspending Pole
EA
F-ERVXQ-D600 ~ F-ERVXQ-D1300
10
Installation Considerations
mepokerkft.hu
Dieses Handbuch passt für folgende Modelle
5
Inhaltsverzeichnis