1.0 Introduction
Congratulations on purchasing the Flex-Pro variable speed Peristaltic Metering Pump. A peristaltic pump is a type
of positive displacement pump used for pumping a variety of fluids.
Your Flex-Pro pump is pre-configured for the tubing that shipped with your metering pump. The tubing assembly
has an Identification number printed for easy re-order.
Please Note: Your new pump has been pressure tested at the factory with clean water before shipping. You may
notice trace amounts of clean water in the pre-installed tube assembly. This is part of our stringent quality assur-
ance program at Blue-White Industries.
Flex-Pro
TABLE OF CONTENTS
Section Heading Page
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Available Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Materials of Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.0 Features.. ... ... ... ... ... ... ... ... ... ... ... ... ... ...5
3.1 Agency Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.0 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Mounting Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Dimensions... ... ... ... ... ... ... ... ... ... ... ... ... ...6
4.3 Installing the Discharge Injection Fitting and Suction Strainer . . . . . . 7
5.0 Input Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.0 How to Operate Flex-Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7.0 Pump Output Speed Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8.0 Contact Closure Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
9.0 Set FVS (flow verification system) . . . . . . . . . . . . . . . . . . . . . . . . . . 11
10.0 Pump Tube Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
11.0 TFD (tube failure detection) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
12.0 Alarm relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
13.0 Reverse Rotor Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
14.0 How To Maintain the Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
15.0 Tube Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
16.0 A2 Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

Page 3
1.1 Available Models
Flex-Pro
®
Tygothane A2 Tube Pumps
Meets FDA criteria for food | Resistant to oils, greases and fuels
GPH
.04 - 3.5
.07 - 7.29
.17 - 17.44
LPH
.13 - 13.2
.27 - 27.6
.66 - 66
ML/Min
2.2 - 220
4.6 - 460
11 - 1100
RPM
125
125
125
115V AC
A2V24-GE
A2V24-GG
A2V24-GH
230V AC
A2V25-GE
A2V25-GG
A2V25-GH
220V AC
A2V26-GE
A2V26-GG
A2V26-GH
®
Gore Style 400, A2V Tube Pumps
Meets FDA criteria for food | Superior chemical resistance
LPH
.56 - 56.4
230V AC
A3V25-VH
115V AC
A3V24-VH
GPH
.15 - 15
220V AC
A3V26-VH
ML/Min
9.4 - 940
RPM
125
®
Norprene A2V Tube Pumps
Meets FDA criteria for food | Excellent chemical resistance | CIP | SIP
LPH
.42 - 42
.05 - 5.4
230V AC
A2V25-ND
A2V25-NH
115V AC
A2V24-ND
A2V24-NH
GPH
.11 - 11.1
.01 - 1.4
220V AC
A3V26-ND
A2V26-NH
ML/Min
.
7 - 700
09 - 90
Feed Rate
RPM
125
125
Max
Speed A3 Model Numbers
PSI (bar)
65 ( )
65 ( )
65 ( )
4.5
4.5
4.5
Max
Pressure
PSI (bar)
125 (8.6)
125 (8.6)
PSI (bar)
65 (4.5)
Max
Temperature
F (C)
185 (85)
185 (85)
F (C)
130 (54)
F (C)
130 (54)
130 (54)
130 (54)
®
Norprene Chemical A2V Tube Pumps
Meets FDA criteria for food | Excellent chemical resistance | Extra long life at low pressures
LPH
.41 - 126
230V AC
A3V25-TH
115V AC
A3V24-TH
GPH
.10 - 10.8
220V AC
A3V26-TH
ML/Min
6.8 - 680
RPM
125
PSI (bar)
50 (3.4)
F (C)
130 (54)
* Inlet/outlet connection type
S = 3/8” OD x 1/4” ID tubing compressions type connections
M = ½” male NPT
C-= 3/4” tri-clamp connections
!The Flex-Pro Pump’s motor speed is linear over the entire 1% to 100% adjustment range.
!Output versus pressure is nearly linear in all models. Larger tubes exhibit greater losses.
!For optimum tube life, specify the pump to operate at the lowest possible RPM and pressure.
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

Page 4
2.0 Specifications
Wetted components: Non-Wetted components:
2.1 Materials of construction
Flex-Pro
Motor speed adjustment range 100:1:
1.0% - 100% motor speed
Motor speed adjustment resolution:
0.1% increments
Maximum viscosity:
12,000 Centipoise
Maximum suction lift:
30 ft. Water, 0 psig (4.5 m, 0 bar)
Display
Backlit LCD, UV resistant.
Keypad
Eight button positive action tactile switch keypad.
Enclosure:
NEMA 4X (IP66), Polyester powder coated aluminum.
Maximum Overall Dimensions:
7-1/2” W x 10-1/4” H x 14” D (19 W x 26 H x 35.6 D cm)
Approximate shipping wt:
25 lb. (12.0 Kg)
Maximum working pressure (excluding pump tubes):
125 psig (8.6 bar)
Note: see individual pump tube assembly maximum pressure ratings.
Maximum Fluid temperature (excluding pump tubes):
oo
3/8” OD x 1/4” ID tubing connections: 130 F (54 C)
oo
M/NPT connections: 185 F (85 C)
Note: see individual pump tube assembly maximum temperature ratings.
Ambient Operating Temperature
OOOO
14 F to 115 F (-10 C to 46 C)
Ambient Storage Temperature
OOOO
-40 F to 158 F (-40 C to 70 C)
Operating Voltage:
115VAC/60Hz, 1ph (1.5 Amp Maximum)
230VAC/60Hz, 1ph (0.7 Amp Maximum)
220VAC/50Hz, 1ph (1.0 Amp Maximum)
240VAC/50Hz, 1ph (1.0 Amp Maximum)
Power Cord Options:
115V60Hz = NEMA 5/15 (USA)
230V60Hz = NEMA 6/15 (USA)
220V50Hz = CEE 7/VII (EU)
240V50Hz = AS 3112 (Australia/New Zealand)
Duty cycle:
Continuous
Enclosure:
413 Aluminum (Polyester powder coated)
Pump Head:
q
Valox (PBT) thermoplastic
Pump Head Cover:
Clear Acrylic - Annealed for added strength and chemical resistance.
Permanently lubricated sealed motor shaft support ball bearing.
Brass shaft support bearing retainer.
Cover Screws:
Stainless Steel
Roller Assembly:
q
Rotor:..................................Valox (PBT)
Rollers: ...............................Nylon
Roller Bearings: .................SS Ball Bearings
Motor Shaft:
Chrome plated steel
TFD System Sensor pins:
Hastelloy C-276
Power Cord:
3 conductor, SJTW-A Water-resistant
Tube Installation Tool:
GF Nylon
Mounting Brackets and Hardware:
316 Stainless Steel
Pump Tube Assembly (Model Specific - 2 provided):
q q q
Tubing: .....Norprene or Norprene Chemical or Tygothane
Adapter fittings: .PVDF
Injection / Back-flow Check valve:
Body & insert: . . . . . . PVDF
Check Ball: . . . . . . . . Ceramic
Spring: ..... .....Hastelloy C-276
q
Ball Seat O-ring: . . . . . Viton (optional EPDM)
q
Static Seal O-ring: ....Viton (optional EPDM)
q
Duckbill anti-scale valve: Santoprene
Ancillary Items provided
With “S” tubing type connections only:
Suction Tubing: . . . . . 3/8” OD x 1/4” ID x 10’ Clear PVC
Discharge Tubing: . . . . 3/8” OD x 1/4” ID x 10’ Polyethylene (LLDPE)
Suction Strainer: . . . . . Polypropylene
With “B” tubing and “M” M/NPT connections only:
Suction Strainer:
Body: .................PVDF
Check Ball: ............Ceramic
q
Ball Seat O-ring: ........Viton (optional EPDM)
With “C” Tri-clamp connections only:
none
TDS #85000-114 rev. 100611
E
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

3.0 Features
Page 5 Flex-Pro
!Peristaltic pump design does not have valves that can clog requiring maintenance.
!Self priming - even against maximum line pressure. By-pass valves are not required.
Cannot vapor lock or lose prime.
!100:1 turndown ratio.
!Operator friendly digital touch pad.
!Backlit LCD displays motor speed, input signal values, service and alarm status.
!Outputs include: one 250V/1A relay to monitor TFD (Tube Failure System) and FVS
(Flow Verification System)
!Two CNC precision machined squeeze rollers and two alignment rollers for optimum
squeeze, unparalleled accuracy, and tube life.
!Heavy duty rotor - single piece plastic rotor means no flexing and increased accuracy
with no metal springs or hinges to corrode.
!Inject at maximum pressure in either direction (clockwise and counter clockwise).
!Output rates to: 17 GPH (64 LPH) and pressures to 125 PSI (8.6 Bar).
!Variable speed DC motor.
!Specially engineered tubing for long life at high pressures. Meets FDA 21 CFR
requirements for food contact applications.
!Patented Tube Failure Detection (TFD) system. Senses tube failure by detecting
chemical in the pump head. No false triggering.
!Compatible with Blue-White’s output Flow Verification Sensor (FVS) system.
Enclosure Rating:
NEMA 4X: Constructed for either indoor or outdoor use to provide a degree of protection to personnel against
incidental contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation of ice
on enclosure.
IP66: No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure from
any direction shall have no harmful effects.
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

Page 6
4.0 Installation
4.1 Mounting Location
Choose an area located near chemical supply tank, chemical injection point, and electrical supply. Install pump
where it can be easily serviced.
!316SS Mounting brackets are included. Mount pump to a secure surface using enclosed mounting hardware.
!Mount pump close to injection point. Keep inlet (suction) and outlet (discharge) tubing as short as possible.
Longer discharge tubing increases back pressure at pump head.
!A back flow prevention check valve is recommended at the discharge of the pump to prevent system fluid from
flowing back through the pump during tube replacement or if the tube should rupture.
!A pressure relief valve is recommended at the discharge of the pump to prevent premature wear and damage to
the pump tube in the event the discharge line becomes blocked.
!The Flex-Pro does not require back pressure. Keep the discharge pressure as low as possible to maximize tube
life.
4.2 Dimensions
All diagrams are strictly for guideline purposes only. Always consult an expert before
installing metering pump on specialized systems. Metering pump should be serviced by
qualified persons only.
nRaise metering pump 4-1/2 inches (11.43 cm) off ground or a surface.
nMade out of tough Stainless Steel.
nProvides a stable mounting surface.
Stainless Steel extended brackets allow pump to be securely mounted to most any surface;
floor, shelf, or skid. Brackets lift pump up 4-1/2 inches (11.43 cm), for easy pump access in
hard to reach areas.
Model #
72000-380
Description
Extended Mounting Bracket, 1 Pair, SS, 4 SS Screws
OptionalExtended Brackets
Model Number 72000-380
!
Always wear protective clothing, face shield, safety glasses and gloves when working on
or near your metering pump. Additional precautions should be taken depending on
solution being pumped. Refer to MSDS precautions from your solution supplier.
Risk of chemical overdose. Be certain pump does not overdose chemical during
backwash and periods of no flow in circulation system.
CAUTION
!
CAUTION
!
CAUTION
Flex-Pro
Dim Inches cm
A
B
C
D
E
10-1/4”
7-1/2”
14”
9-1/2”
11”
26
19
35.6
24.1
27.9
A2 Series
F3-3/8” 8.6
A
F
B
E
C
D
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

Page 7
Discharge
Tubing
Tube retaining
nut
Injection
Check valve
Pipe tee
½” male NPT
1/4” male NPT
Discharge Injection / Check Valve
Discharge
Pipe or
½” Tubing
(not included)
Discharge Injection / Check Valve
Pipe
Tee Install
upward
for best
results
½” Male NPT
½” Male NPT
or ½” Hose Barb
Suction Strainer
1/2” Male NPT Connection and 1/2”Hose Barb Models
Suction Tubing and Strainer
Ceramic
Weight
PVC Suction Tubing
3/8" OD x 1/4” ID
Polypropylene
Strainer
Duckbill is used to help reduce
calcium buildup when injecting
chemicals that calcify (such as
sodium hypochlorite). Duckbill
may add additional back
pressure to pump (up to 7 psi).
3/8”OD x 1/4” ID Tubing and Tri-Clamp connection Models
Proper eye and skin protection must be worn when installing and servicing pump.
!CAUTION
This Pump Has Been Evaluated for Use with Water Only.
!CAUTION
4.3 Installing Discharge Injection Fitting and Suction Strainer
PVDF
PVDF
Viton (optional EP)
T/FEP (optional EP)
Hastelloy C-276
Ceramic
Suction
Strainer
½” Male NPT
or ½” Hose Barb PVDF
PVDF
Viton (optional EP)
Polypropylene
Removable
275 Micron
Filter
PVDF
Hastelloy C-276
PVDF
T/FEP (optional EP)
Ceramic
Viton (optional EP)
Santoprene
PVDF
Flex-Pro
CLICK HERE TO RETURN TO WEBSITE

Page 8
5.0 Input Power Connections
Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Three power cord plug types available.
Power cord length is 6 feet (3.83 meters)
WARNING
!Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage pump and may result in
injury. Voltage requirement is printed on pump serial label.
!Input power range is 96VAC to 264VAC 50/60 Hz.
!Voltage Selection is automatically detected and adjusted by power supply. No mechanical switch necessary.
!Use voltage your power cord is rated for.
!Cord connected models are supplied with a ground wire conductor and a grounding type attachment plug (power
cord). To reduce risk of electric shock, be certain that power cord is connected only to a properly grounded,
grounding type receptacle.
!Permanently connected models must be properly grounded. Be certain that a grounding conductor is connected
to terminal T11-1 located in the wiring compartment.
!Never strap control (input / output) cables and power cables together.
!Power Interruption: This pump has an auto-restart feature which will restore pump to operating state it was in
when power was lost.
Note: When in doubt regarding your electrical installation, contact a licensed electrician.
Electrical connections and grounding (earthing) must conform to local wiring codes.
Be certain that a grounding conductor is connected to terminal T11-1 located in the
wiring compartment.
WARNING
115V 60Hz
NEMA 5/15 (USA)
max: 125V AC
230V 60Hz
NEMA 6/15 (USA)
max: 250V AC
240V 50Hz
CEE 7/VII (EU)
max: 250V AC
QTY. DESCRIPTION
2.50 INCH (12.7 mm) LIQ-TIGHT HOLE PLUGS (MAT’L = NEOPRENE), PRE-INSTALLED
3.875 INCH (22.2 mm) LIQ-TIGHT HOLE PLUGS (MAT’L = NEOPRENE), 2 PRE-INSTALLED
2.50 INCH (12.7 mm) LIQ-TIGHT CONNECTORS FOR PASS THRU CORDS (MAT’L = NYLON)
ACCEPTABLE CABLE DIAMETER .118 TO .255 INCH (3.0 TO 6.5 MM), NOT INSTALLED
3.875 INCH (22.2 mm) METALLIC LIQ-TIGHT CONNECTORS FOR PASS THRU CORDS (MAT’L = NYLON)
ACCEPTABLE CABLE DIAMETER .200 TO .395 INCH (5.1 TO =10.0 MM), 1 PRE-INSTALLED WITH POWER CORD MODELS
Cable and conduit connectors included
5.99 in.
(152.1 mm)
Ø
(12.7 mm)
2-PLCS.
.50 Ø
(21.3 mm)
3-PLCS.
.84 in.
WIRING COMPARTMENT COVER POWER CORD OPTIONS
Risk of electric shock - Disconnect electricity before removing the wiring
compartment cover.
WARNING
Flex-Pro
2METALLIC LIQ-TIGHT CONNECTORS FOR .50 INCH FLEXIBLE CONDUIT (MAT’L = DIE CAST ZINC), NOT INSTALLED
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Electrical connections and grounding (earthing) must conform to local wiring codes.
Be certain that a grounding conductor is connected to terminal T11-1 located in the
wiring compartment.
Risk of electric shock - Disconnect electricity before removing the wiring
compartment cover.
Page 9 Flex-Pro
To PRIME pump
Press PRIME button to start 60 second prime feature. Pump will run at full speed for 60 seconds or
until STOP or START button is pressed. STOP button will stop pump and display will read OFF. START
button will stop prime feature and jump back into previous operating state.
To REVERSE ROTATION of rotor
Press REVERSE ROTATION button to reverse flow.
6.0 How To Operate Flex-Pro
Flex-Pro Control Panel - Button Operation
To STOP pump at any time
Pump can be stopped at any time by pressing STOP button.
overrides all other controls and stops pump. Display will read OFF if pump has
been stopped in this manner. Pump will not respond to incoming input signals
while in OFF state. When START button is pressed, pump will start according to
it’s previous operating state.
STOP button
To START pump
Press START button to start pump. If a remote start/stop input signal is used, the pump will begin
“listening” for the input signal.
Pressing the START button repeatedly will toggle the display to indicate the %SPEED, RPM, and Tube
Timer Hours.
UP Arrow
Press UP arrow to increase pump output.
Press UP arrow to navigate through menu items.
DOWN Arrow
Press DOWN arrow to increase pump output.
Press DOWN arrow to navigate through menu items.
CAUTION: Motor will reverse its rotation immediately after the REVERSE ROTATION button is pressed.
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE

Page 10 Flex-Pro
7.0 Pump Output Speed Adjustment
Press UP arrow to increase pump output. Press DOWN arrow to increase
pump output.
8.0 Contact Closure Input (Remote Start/Stop)
Used to remotely start and stop the pump using a close=run or open=stop signal. If the pump must
start when the loop is open, then select “Close: Stop Pump” option. Can be used with an external
foot pedal, a PLC, contact closure, or other similar external devices.
Default settings: Disable
CC Input Range: 6 - 30 VDC
or
Dry Contact Closure (no voltage required)
[See section 5.1 for wire connections]
Navigate to Contact Input menu by holding the START button for 5 second. While motor is off.
Press UP or DOWN arrow to scroll through your options.
Press START to make a selection. The radio button (square box) is now filled in next to your
selection.
Press DOWN arrow to scroll down to Done selection. Then press START.
IMPORTANT: To begin operation, press the START button to place pump in STANDBY. The display
background will turn blue indicating the pump has been stopped remotely. When the pump is
started by the remote contact, the display background will turn green.
IMPORTANT: If the Contact Closure Input is enabled, the pump will display STANDBY if the pump
has been stopped by the Remote Contact Closure. Please use caution in this mode as the pump
may Start at anytime. If you must perform maintenance to the pump, Press STOP button.
When Contact Closure Input is enabled, the word Remote will always be displayed on the lower left
side of the display screen.
OPERATING
FLOW RANGE
(ml/min)
CALL 1-800-577-8111 FOR SALES AND SUPPORT
CLICK HERE TO RETURN TO WEBSITE
Dieses Handbuch passt für folgende Modelle
20
Andere Flex-Pro Wasserpumpe Handbücher
Beliebte Wasserpumpe Handbücher anderer Marken

Sykes AmeriPumps
Sykes AmeriPumps GP100M Fehlerbehebungshandbuch

DUROMAX
DUROMAX XP WX Series Bedienungsanleitung

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Bedienungsanleitung

Franklin Electric
Franklin Electric IPS Bedienungsanleitung

Xylem
Xylem e-1532 Series Bedienungsanleitung

Milton Roy
Milton Roy PRIMEROYAL Bedienungsanleitung