FMS RTM MP Plus EMGZ482T.PLUS.MP.W.24VDC Bedienungsanleitung

Operation Manual RTM MP Plus
EMGZ482T.PLUS.MP.W.24VDC
EMGZ482R.MP and EMGZ443MP.R
Multi-Purpose Radio Transmission Tension Monitoring System
with Encoder Signal Evaluation
Document Version 1.4 01/2019 NS
Firmware Version V 3.03
Diese Bedienungsanleitung ist auch in Deutsch erhältlich.
Bitte kontaktieren Sie Ihren nächstgelegenen FMS Vertreter.
© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.

Operation Manual RTM MP Plus
06.03.2019 2
Table of Contents
1 Safety Instructions ..................................................................................... 3
1.1 Description conditions 3
1.2 List of Safety Instructions 4
2 System Description .................................................................................... 4
2.1 Functional Description RTM MP System 4
2.2 Main System Components 6
3 Certifications and Compliancy ................................................................. 7
4 Installation and Wiring .............................................................................. 9
4.1 Area of Machine Rotation 9
4.2 Static installation of force sensor 9
4.3 Installation of Force Sensors on a Rotating Machine Part 9
4.4 Mounting and Wiring the Electronic Components 10
4.5 Mounting and Wiring the EMGZ482T.PLUS.MP.W.24VDC 11
4.6 Components on the Static Part of the Machine 12
4.7 In- and Output Schematics RTM MP 13
4.8 Wiring the Receiver EMGZ482R.MP 15
4.9 Connectors EMGZ443MP.R (static machine part) 16
5 Configuration of the RTM MP System ................................................... 18
5.1 RTM MP Quick Start 18
5.2 Description of the Operating Panel EMGZ482R.MP 18
5.3 Offset Compensation Procedure 19
5.4 Calibration Methods 20
5.5 Calibration Procedure 20
5.6 Relay Output for Lost Communication 20
6 Mechanical Dimensions .......................................................................... 21
7 Trouble Shooting ...................................................................................... 22
8 Technical Data ......................................................................................... 23

Operation Manual RTM MP Plus
06.03.2019 3
1 Safety Instructions
All safety related regulations, local codes and instructions that appear in the manual
or on equipment must be observed to ensure personal safety and to prevent damage
to the equipment connected to it. If equipment is used in a manner not specified by
the manufacturer, the protection provided by the equipment may be impaired.
Do not stress the equipment over the specification limits neither during assembly nor
operation. To do so can be potentially harmful to persons or equipment in the event
of a fault to the equipment.
1.1 Description conditions
a) Danger of health injury or loss of life
Danger
This symbol refers to high risk for persons to get health injury or loss life. It has to be
followed strictly.
b) Risk of damage of machines
Caution
This symbol refers to information, that if ignored, could cause heavy mechanical
damage. This warning has to be followed absolutely.
c) Note for proper function
Note
This symbol refers to an important information about proper use. If not followed,
malfunction can be the result.

Operation Manual RTM MP Plus
06.03.2019 4
1.2 List of Safety Instructions
Changes or modifications made to this equipment not expressly approved by
(manufacturer name) may void the FCC authorization to operate this equipment.
This devise complies with Part 15 of the FCC Rules and with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this devise may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Radiofrequency radiation exposure Information.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance of 20 cm between the radiator and your body: This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
It is of paramount importance to compensate the centrifugal forces caused by the
rotating base plate of the stranding machine. The measuring results will be wrong, if
this rule is broken.
Proper function of the FMS RTM MP System can only be guaranteed with the
recommended application of the components. Other arrangements can cause
malfunctions. Therefore, the installation instructions on the following pages must be
followed.
Local installation regulations are to preserve safety of electric equipment. They are not
taken into consideration by this operating manual. However, they have to be followed
strictly.
The shield should be connected only to the electronic unit. On the force sensor side the
shield should stay open.
Bad earth ground connection may cause electric shock to persons, malfunction of the
total system or damage of the electronic unit! It is vital to ensure that proper earth
connection is done.
The sensor cables must be installed separate from power lines.
2 System Description
2.1 Functional Description RTM MP System
FMS’ RTM MP System has been developed to measure and evaluate all kind of
production relevant parameters in Wire Processing Machinery (especially in Bow Type
Stranding Machines). The System consists of a combined transmitter-decoding unit, a
receiver and further decoding modules in the receiver part. RTM MP uses two force
sensors for the measurement of the wire tension. Encoder signals and wire tension

Operation Manual RTM MP Plus
06.03.2019 5
values are captured, conditioned and sent over a 2.4 GHz wireless link to the receiver
unit EMGZ 48R.MP. Further processing of the encoder signals takes place in the
decoding module EMGZ443R.MP Here all relevant data for the actuator drivers or the
machine control is available. A fully equipped system can handle up to 16 digital
inputs and outputs, two force measuring rollers and 2 encoder channels. The later
can e.g. be used for close loop control of drives and the control of the traverse guide
in individual bobbins.
Fig. 1: Block diagram of RTM MP system RTM_MP_BA_Manual.ai

Operation Manual RTM MP Plus
06.03.2019 6
2.2 Main System Components
RMGZ Force Measuring Rollers
● Measures the wire tension
● Converts the tension values in an electrical signal
EMGZ482T.PLUS.MP.W.24VDC
● Amplification and conditioning of the electrical signals
● Wireless transmission (antenna is integrated on
front plate
● Power supply 24 VDC via slip rings
● I/O Configuration:
- 1x Analogue output 0…10V or 4…20mA
- 1x Analogue input 0…10V or 4…20mA
- 2x Encoder Inputs
- 8x Dig. outputs
- 8x Dig. inputs
EMGZ482R.MP
● Wireless reception of tension data
● Offset compensation
● Bus connection to EMGZ443MP.R
● Data transfer to EMGZ443MP.R and PLC.
EMGZ443MP.R Decoding Module receiver Side
● Expansion of I/O Configuration by:
- 1x Analogue output 0…10V or 4…20mA
- 1x Analogue input 0…10V or 4…20mA
- 2x Encoder outputs
- 8x Dig. outputs
- 8x Dig. inputs

Operation Manual RTM MP Plus
06.03.2019 7
3 Certifications and Compliancy
This equipment has been tested and found to comply with following rules:
ETSI Radio Certification
Magnitude of Test (Coverage) Article 3.2 of Directive 1999/5/EC (R&TTE
Directive)
Certification ETSI EN 300 440
-
2 V1.5.1 (2009
-
03)
ETSI EN 300 440
-
1 V1.3.1 (2009
-
03)
ETSI EMC Certification
Magnitude of Test (Coverage) ECM
-
Test according to 98/37/EC and
2004/108/EC harmonized
Emission and Immunity Test ETSI EN 489
-
3
EN 61326
-
1
FCC Certification
Magnitude of Test Class A digital device, pursuant to Part 15 of the
FCC Rules
Certification FCC Registration #: 0020311882
Note
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.

Operation Manual RTM MP Plus
06.03.2019 8
Caution
Changes or modifications made to this equipment not expressly approved by
(manufacturer name) may void the FCC authorization to operate this equipment.
Caution
This devise complies with Part 15 of the FCC Rules and with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation
Caution
Radiofrequency radiation exposure Information.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance of 20 cm between the radiator and your body:
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.

Operation Manual RTM MP Plus
06.03.2019 9
4 Installation and Wiring
4.1 Area of Machine Rotation
Following RTM MP components are installed either on the rotating part of the machine
or in the area of machine rotation:
● Transmitter EMGZ482T.MP.PLUS.W.24VDC
● RMGZ Force Measuring Rollers
4.2 Static installation of force sensor
Fig. 2: RMGZ Red Point alignment on static machine parts
RTM_X42_Red_Point_Allignment_BA_Manua.ai
The red point should always be aligned in the direction of the resulting Force (see Fig.
2). For further mounting information please consult the respective installation manual
of the sensor. The installation manual is always delivered together with the sensor.
4.3 Installation of Force Sensors on a Rotating Machine Part
Note
In rotating applications the force measuring sensors are mounted such that
centrifugal forces are compensated. If using FMS RMGZ sensors, this can be achieved
by turning the Red Point parallel to the rotation axis and in direction of the positive
force component (refer to Fig. 3).
Note
The adjustment of the red point can be tested after offset compensation and
calibration. If the reading of an unloaded load cell stays at zero regardless of the load
cell position (e.g. at 12 o’clock or at 6 o’clock position), the red point is correctly
aligned.

Operation Manual RTM MP Plus
06.03.2019 10
Fig. 3: RMGZ Red Point alignment on rotating machine parts
RTM_X42_Red_Point_Allignment_BA_Manua.ai
Caution
It is of paramount importance to compensate the centrifugal forces caused by the
rotating base plate of the stranding machine. The measuring results will be wrong, if
this rule is broken.
4.4 Mounting and Wiring the Electronic Components
An RTM MP system is usually delivered complete with all its components and cables.
The cables are prepared with connectors on both sides for easy assembly
Caution
Proper function of the FMS RTM MP system can only be guaranteed with the
recommended application of the components. Other arrangements can cause
malfunctions. Therefore, the installation instructions on the following pages must be
followed.
Caution
Local installation regulations are to preserve safety of electric equipment. They are
not taken into consideration by this operating manual. However, they have to be
followed strictly.
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere FMS Sender Handbücher
Beliebte Sender Handbücher anderer Marken

Dejero
Dejero EnGo 3x Bedienungsanleitung

Rosemount
Rosemount 4600 Bedienungsanleitung

Speaka Professional
Speaka Professional 2342740 Bedienungsanleitung

trubomat
trubomat GAB 1000 Bedienungsanleitung

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Bedienungsanleitung

Rondish
Rondish UT-11 Bedienungsanleitung