Furuno FCV-38 Bedienungsanleitung

www.furuno.com
A
ll brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Installation Manual
Stabilized FISH SIZE INDICATOR
Model FCV-38
(Product Name: FISH FINDER)
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATIONS........................................................................................ iii
EQUIPMENT LISTS........................................................................................................ iv
1. MOUNTING..............................................................................................................1-1
1.1 Processor Unit ...................................................................................................................1-1
1.2 Transceiver Unit.................................................................................................................1-3
1.3 Trackball Control Unit ........................................................................................................1-4
1.4 Transducer.........................................................................................................................1-7
1.5 Junction Box (Option) ......................................................................................................1-10
1.6 DVI/USB Repeater (Option).............................................................................................1-10
2. WIRING....................................................................................................................2-1
2.1 Processor unit ....................................................................................................................2-2
2.2 Transceiver Unit.................................................................................................................2-6
2.3 Trackball Control Unit ........................................................................................................2-8
2.4 Transducer.......................................................................................................................2-10
2.5 Junction Box (option) .......................................................................................................2-11
2.6 DVI/USB Repeater (Option).............................................................................................2-13
2.7 Input/Output Sentences (NMEA0183) .............................................................................2-14
3. INITIAL SETTINGS..................................................................................................3-1
3.1 How to Set the Language and Measurement Unit .............................................................3-1
3.2 How to Set the [Service] Menu ..........................................................................................3-2
3.3 Communication Port Setting ..............................................................................................3-7
3.4 External Echo Sounder Setting........................................................................................3-10
3.5 Calibration Setting............................................................................................................3-12
3.6 Stabilization Setting .........................................................................................................3-16
3.7 How to Take a Still Image of the RX Monitor...................................................................3-19
3.8 Reset to Default Setting...................................................................................................3-19
3.9 Retrofit from FCV-30........................................................................................................3-20
APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1
PACKING LISTS ......................................................................................................... A-1
OUTLINE DRAWINGS ................................................................................................ D-1
INTERCONNECTION DIAGRAMS.............................................................................. S-1

7KHSDSHUXVHGLQWKLVPDQXDO
LVHOHPHQWDOFKORULQHIUHH
࣭)85812$XWKRUL]HG'LVWULEXWRU'HDOHU
$VKLKDUDFKR
1LVKLQRPL\D-$3$1
$ 6(3
3ULQWHGLQ-DSDQ
$OOULJKWVUHVHUYHG
3XE1R ,0($
$.08 )&9

i
SAFETY INSTRUCTIONS
The installer must read the applicable safety instructions before attempting to operate or install the
equipment.
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
can result in minor or moderate injury.
CAUTION
Warning, Caution Prohibitive Action Mandatory Action
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment unless
totally familiar with electrical circuits
and service manual.
Only qualified personnel are allowed to
work inside the equipment.
Turn off the power at the mains
switchboard before beginning the
installation.
Fire, electrical shock or serious injury can
result if the power is left on or is applied
while the equipment is being installed.
Install the transducer according to the
installation instructions.
Failure to install the transducer correctly
may result in water leakage and damage
to the ship's hull.
For wooden or FRP vessel using a
steel tank, attach a zinc plate to the
hull to prevent electrolytic corrosion.
Electrolytic corrosion can, in the worst
case, result in loss of the transducer.
Be sure no water leaks in at the
transducer mounting location.
Water leakage can sink the vessel. Also,
confirm that the transducer will not be
loosened by ship vibrations. The installer
of the equipment is solely responsible
for the proper installation of the
equipment. FURUNO will assume no
responsibility for any damage associated
with improper installation.
CAUTION
Observe the following safe compass
distances to prevent interference to a
magnetic compass:
Do not transmit with the transducer
out of water.
The transducer may become damaged.
Use the proper cable and fuse.
Use of an incorrect cable and fuse can
damage the equipment and cause fire.
Standard
compass
Steering
compass
2.15 m 1.35 m
Processor Unit
(CV-380)
2.15 m 1.35 m
Transceiver Unit
(CV-382)
0.30 m 0.30 m
Trackball Control Unit
(RCU-026)
1.10 m 0.70 m
Junction Box
(CV-304)
0.35 m 0.30 m
DVI/USB Repeater
(TM000-FDX06)
Ground the equipment to prevent
electrical shock and mutual
interference.

SAFETY INSTRUCTIONS
ii
CAUTION
Do not allow warm water or any other
liquid other than seawater or
freshwater to contact the transducer.
Damage to the transducer may result.
The transducer cable must handled
carefully, following the guidelines
below.
- Keep the cable away from oil and fuels.
- Keep the cable away from locations
where it may be damaged during the
installation.
- Do not carry the transducer using only
the cable. The cable may become
damaged or disconnected.
- Do not shorten the transducer cable.
- Do not paint the cable.
The cable sheath is made of chloroprene
or vinyl chloride, which are easily dam-
aged by plastic solvents such as toluene.
Locate the cables away from plastic
solvents.
Do not install the transducer where
noise or air bubbles is present.
Performance will be affected.

iii
SYSTEM CONFIGURATIONS
RS-485
USB䠆2
RS-485
USB䠆2
USB port
USB3.0: 2 ports
USB2.0: 2 ports
100/110/115/
220/230 VAC
1ø, 50/60Hz
Display Unit*3
USB device䠆2
USB device䠆2
*1䠖A maximum of four USB devices including RCU-026 can be connected to the processor unit.
*2: To use the USB port on the RCU-026, connect the RCU-026 to the USB port on the processor
unit, using the USB cable supplied with the RCU-026. If you do not use the USB port on the
RCU-026, the USB connection between the RCU-026 and processor unit is not required.
*3: To extend the distance between the processor unit and the monitor unit/USB device, use the
optional DVI/USB repeater.
*4: The transceiver unit CV-302 for FCV-30 is available.
Rectifier Unit
RU-1746B-2
or
AC/DC Power
Supply Unit
PR-241
:
Standard supply
:
Optional or local supply
External KP
Trackball
Control Unit
RCU-026
Trackball
Control Unit
RCU-026
12-24 VDC
NMEA 0183 port,
5 ports
NETWORK2 port
NETWORK1
port
USB device*1, *3
(USB mouse,
USB flash memory,
USB keyboard, etc.)
HDMI port 2 ports
Processor
Unit
CV-380
100-120/220-240 VAC
1ø, 50/60 Hz
Nav equipment,
Satellite compassTM,
Radio communication,
Net sonde, etc.
Junction Box
CV-304
Transceiver
Unit䠆4
CV-382
Transducer
CV-303
Ethernet
HUB
HUB-101
Network
Sounder
DFF3

iv
EQUIPMENT LISTS
Standard supply
Optional supply
Name Type Code No. Qty Remarks
Processor Unit CV-380 - 1
Transceiver Unit CV-382 - 1
Trackball Control
Unit
RCU-026 - 1
Transducer CV-303 *ROHS* - 1 15 m cable (φ22 mm),
w/data sheet sticker (silver)
Thru-Hull Pipe TFB-1600 - 1
Installation
Materials
CP24-02900(10M) 001-208-050
1
LAN cable between
processor unit and
transceiver unit
10 m
CP24-02910(20M) 001-208-060 20 m
CP24-02920(30M) 001-208-070 30 m
Installation
Materials
CP10-09700 000-036-275 1 For processor unit
CP02-09801 001-581-570 1 For transceiver unit
CP24-02300 000-027-673 1 For RCU-026
Accessories FP24-00801 001-418-410 1 For RCU-026
Spare Parts SP02-06001 001-569-280 1 For processor unit
SP03-17661 001-249-760 1 For transceiver unit
Name Type Code No. Remarks
Junction Box CV-304-10 - 10 m cable
CV-304-20 - 20 m cable
CV-304-50 - 50 m cable
Rectifier Unit RU-1746B-2 000-030-439
AC/DC
Power Supply Unit
PR-241 000-037-820
Cable Assembly HDMI-TO-DVI-L=10.3M 001-407-170 HDMI cable be-
tween proces-
sor unit and
display unit
10.3 m
HDMI-TO-DVI-L=5.3M 001-407-180 5.3 m
Ethernet Hub HUB-101 000-011-762
Cable Assembly 6TPSH-XH12X2-L5.0SP2 001-186-310-10 For RCU-026 5 m
6TPSH-XH12X2-L10SP2 001-186-320-10 10 m
Flush Mount OP24-27 001-171-820 For RCU-026
Transducer Fixing
Kit
T-625-A 001-096-720 For noise reduction
caused by ship move-
ment.
Cable Assembly PARTS_WO2511 001-578-140 LAN cable for
DVI/USB
repeater
30 m
PARTS_WO2512 001-578-150 50 m
PARTS_WO2513 001-578-160 100 m

EQUIPMENT LISTS
v
Installation
Materials
CP10-10100 000-036-244 LAN cable be-
tween proces-
sor unit and
transceiver unit
(Waterproof
type)
10 m
CP10-10110 000-036-245 15 m
CP10-10120 000-036-246 30 m
CP10-10130 000-036-247 40 m
CP10-10140 000-036-248 50 m
CP10-10150 000-036-722 100 m
DVI/USB Repeater TM000-FDX06_TXRX_30M 001-578-110 TX/RX units
w/LAN cable
30 m
TM000-FDX06_TXRX_50M 001-578-170 50 m
TM000-FDX06_TXRX_100M 001-578-180 100 m
TM000-FDX06_TXRX 001-578-190 TX/RX units
TM000-FDX06_RX 001-578-120 RX unit
TM000-FDX06_TX 001-578-130 TX unit
Cable Assembly MJ-A3SPF0024-035C 000-157-943-10
RNS-08-132 001-107-540-10 5 m cable between DVI/
USB repeater (TX) and
the processor unit
Name Type Code No. Remarks

EQUIPMENT LISTS
vi
This page is intentionally left blank.

1-1
1. MOUNTING
1.1 Processor Unit
The processor unit can be installed on a deck or bulkhead.
Mounting consideration
Select a mounting location, keeping in mind the following points:
• Locate the unit out of direct sunlight and away from heat sources.
• Locate the unit away from places subject to water splash and rain.
• Select a mounting location considering the length of the cables to be connected to
the unit.
• Select a location where shock and vibration are minimal.
• Be sure the mounting location is strong enough to support the weight of the unit.
• Referring to the outline drawings at the back of this manual, allow sufficient space
for maintenance and service.
• A magnetic compass will be affected if the unit is placed too close to the magnetic
compass. Observe the compass safe distances at the front of this manual to prevent
interference to a magnetic compass.
• For bulkhead installations, secure the unit so that the cable entrance faces down-
ward.
NOTICE
Do not apply paint, anti-corrosive sealant or contact spray to
coating or plastic parts of the equipment.
Those items contain organic solvents that can damage
coating and plastic parts, especially plastic connectors.

1. MOUNTING
1-2
1.1.1 Deck mount
1. Drill four pilot holes in the mounting location for mounting bolts (M6 bolts or coach
screws φ6), referring to the outline drawing at the back of this manual.
2. Secure the unit using the four hex head slot bolts (M6×20, supplied).
1.1.2 Bulkhead mount
1. Drill four pilot holes in the mounting location for mounting bolts (M6×20, supplied),
referring to the outline drawing at the back of this manual.
2. Screw two hex head slot bolts into the lower pilot holes. Leave 5 mm of thread vis-
ible.
3. Set the notches of the unit onto the screws fastened at step 2.
4. Screw two hex head slot bolts into the upper fixing holes.
5. Fasten all screws tightly to secure the unit in place.
Hex head slot bolt
(M6×20, 4 pcs䠅
Detailed view
Set the notches of the unit
to the bolts.
Hex head slot bolt
(M6×20, 4 pcs䠅
Andere Handbücher für FCV-38
1
Inhaltsverzeichnis
Andere Furuno Bootsausrüstung Handbücher

Furuno
Furuno GP-1870F Bedienungsanleitung

Furuno
Furuno LH-3000 Bedienungsanleitung

Furuno
Furuno FELCOM 250 Bedienungsanleitung

Furuno
Furuno GS-100 Bedienungsanleitung

Furuno
Furuno FELCOM 250 Bedienungsanleitung

Furuno
Furuno DS-80 Bedienungsanleitung

Furuno
Furuno TZTL12F Bedienungsanleitung

Furuno
Furuno GP-1640F Bedienungsanleitung
Beliebte Bootsausrüstung Handbücher anderer Marken

Dowco
Dowco V322 CC - 2019 Bedienungsanleitung

Humphree
Humphree HCS-5 Bedienungsanleitung

Vetus
Vetus BOW4512D Technisches Datenblatt

Dock Doctors
Dock Doctors SLIDING BOARDING STEP Bedienungsanleitung

Mastervolt
Mastervolt Mass Combi 12/2000-100 Original Betriebsanleitung

Zattini Group
Zattini Group bamar BOXTRON E14S Benutzerhandbuch