Galls ST300 Bedienungsanleitung

PLIT301GALLS REV. D 6/18/14
ST300
Street Commander
SIREN AMPLIFIER & LIGHT CONTROLLER
INSTALLATION AND OPERATING INSTRUCTIONS
1340 Russell Cave Road / P.O. Bo 54308 Le ington, KY 40505
Tel: (800) 477-7766 Fa : (800) 944-2557
www.galls.com
Street Thunder™
Street Thunder™Street Thunder™
Street Thunder™

-i-
TABLE OF CONTENTS
INSTALLATION INFORMATION TABLE 1
GENERAL DESCRIPTION 1-2
INSTALLATION 2-17
PACKAGE CONTENTS 2
INSTALLER-SELECTABLE OPTIONS (Amplifier) 3-6
INSTALLER-SELECTABLE OPTIONS (Control ead) 7-8
MOUNTING 9-11
ELECTRICAL CONNECTIONS (Siren Amplifier) 12-15
RECOMMENDED WIRE SIZING C ART 12
SIREN WIRING DIAGRAM 14
OPTIONAL RT WIRING DIAGRAM 15
ELECTRICAL CONNECTIONS (Lights) 16-17
LIG T WIRING DIAGRAM 17
BUTTON LABEL INSERTION 18
OPERATION 19-22
GENERAL 19
SLIDE SWITC 19
PUS BUTTON LIG T CONTROLS 19
SIREN CONTROLS 20-21
VOLUME CONTROLS 22
MICROP ONE 22
AUXILIARY INPUT 22
PARK KILL 22
SPEAKER DIAGNOSTICS 22
SERVICE 23-25
TROUBLES OOTING 23
FUSES 24
SPECIFICATIONS 24
PARTS 25
RETURNS 25
LIMITED WARRANTY 26
SWITC FUNCTION TABLE 26
NOTICE
Due to continuous product improvements, we must reserve the right to change any
specifications and information contained in this manual at any time without notice. Galls
and/or the manufacturer make no warranty of any kind with regard to this manual,
including, but not limited to, the implied warranties of merchantability and fitness for a
particular purpose. Galls and/or the manufacturer shall not be liable for errors contained
herein or for incidental or consequential damages in connection with the furnishing,
performance, or use of this manual.

-1-
Installation Information
MODEL:
AMP S/N:
CONTROL HEAD S/N:
PURCHASE DATE:
INSTALLATION DATE:
INSTALLER:
DEALER:
SIREN OPTION DIP SWITCHES LIGHT CONTROL OPTION JUMPERS
_____ Two-Tone Enabled _____ 8 sec. gun lock S4
_____ Pursuit Disable _____ Momentary S3
_____ Phaser Disabled _____ Normally Closed S3
_____ Negative Park Kill Switching _____ RT on Start-up
_____ Negative Auxiliary Switching _____ Audible Beep disable
_____ Auxiliary Override
_____ F on Start-up
_____ S3 Auto Activate
The ST300 series is a premium remote system that combines the siren amplifier, the
siren controls, and light controls all in one system. A single slim-line remote control
head combines the noise-canceling microphone with a built in siren, as well as many
of the switch and light controls for the vehicle. The control head contains illuminated
switches that change color to indicate status. The face of the control head is sealed
around every push button to help prevent li uid from entering the electronics. The
amplifier is a 200W siren amplifier unit designed for single or dual 100W speaker
use.
The control head contains several distinct controls for operation of vehicle devices.
The slide switch allows uick pursuit mode operation. The far right slide position
can be set up to activate maximum lights and siren for pursuit mode. Five push
buttons allow control of five different lighting or auxiliary functions. Seven
additional push buttons allow full siren operation.
The ST300 series is designed to allow maximum versatility in mounting. The control
head is remote from the siren amplifier and light relay control box, creating a
compact user interface that can be mounted onto the dashboard, overhead, or in the
center console. The amplifier box can then be mounted remotely in the trunk, under
the dashboard, under the seat, or wherever convenient. The control head is available
with an adjustable “U” bracket or with a flange for recessed mounting.
General Description

-2-
(General Description CONT’D)
Siren operating modes include Wail, Yelp, Phaser, Hands Free, and Radio. A noise
canceling PA override is available in all modes. A Manual button allows tone toggle
operation and manual siren control. The Air Horn button will override any siren tone.
The vehicle horn switch may also perform the Manual push button function via an
auxiliary input. Twelve option jumpers allow the unit to be fully customized to the
operators' needs. Options include: Phaser vs. Two-Tone, Phaser disable, 8 second
timed gunlock release, momentary vs. lock-on/lock-off switch operation, N.O.
contact vs. N.C. contact, auto horn ring transfer, and many more. A Park Kill option
is provided for connection to a door switch, etc. to disable the siren when exiting the
vehicle. Both a PA volume and a Radio volume are provided.
The ST300 series has been designed with several protection features to provide
exceptional field service. Excessive high or low voltage detection will disable the
siren output, protecting both the amplifier and the speaker. Fused inputs provide
safety against reverse polarity. Speaker diagnostics provides user feedback as well as
shutdown protection against speaker opens and shorts. The first four light output
functions are individually protected with 20A fuses, while the fifth light output
function is protected with a 2A in-line fuse. CAUTION: These protection features
will not guard against overloading the outputs.
Installation
Proper installation of the unit is essential for years of safe, reliable operation.
Please read all instructions before installing the unit. Failure to follow these
instructions can cause serious damage to the unit or vehicle and may void
warranties.
Q alifications - The installer must have a firm knowledge of basic electricity,
vehicle electrical systems, and emergency e uipment.
Keep These Instr ctions - Keep these instructions in the vehicle or other safe
place for future reference. Advise the vehicle
operator of the location.
Unpacking - Immediately inspect the contents for shipping damage. If any
damage is found, alert the carrier immediately.
Contents should include:
1 - remote control head
1 - amplifier and light control box
1 - amplifier wire harness with connector
1 - 25’ amplifier communication cable (6-wire telephone style cable)
1 - mounting hardware
1 - “ ” bracket
1 - label set
1 - installation and operating instructions
Please contact your supplier immediately if any components are missing.

-3-
Installer Selectable Options
The ST300 has several options that can be selected during installation. Various
DIP switches and jumpers on the printed circuit board inside the amplifier case,
inside the control head. These options should be set before installation of the
unit.
Siren option DIP switches (located in the amplifier case):
• Auxiliary input polarity
• Park Kill input polarity
• Two-tone replacement of Phaser tone
• Phaser Disable
• Slide Switch Pursuit Disable
Light control option j mpers (located inside the control head)
• Auxiliary control (Manual vs. Horn)
• 8 second timed gun lock release (S4)
• Momentary replacement of lock-on/lock-off switch operation (S3)
• Normally closed contact replacement of normally open (S3)
• Activate Hands Free on start-up
• Activate Horn Ring Transfer on start-up
• Audible beep disable
• S3 Auto Activate on Position L2 & L3 of Slide Switch
SIREN OPTION DIP SWITCHES
Amplifier Cover Removal
CA TION:
DO NOT
OVER-TIGHTEN
SCREWS!
Loosen the three protr ding Philips head screws located on the top of the
amplifier unit. Slide the cover off.

-4-
(Installer Selectable Options CONT’D)
Diagram showing NEG A X set up
Diagram showing NEG PK set up
A xiliary Inp t Polarity
Applying a positive voltage to the green wire normally activates the auxiliary
function (Air Horn standard/MANUAL function optional). To have the AUX
function instead activate when the green wire is connected to ground (negative)
.
1. Turn “AUX POS” DIP switch off (shown above).
2. Turn “AUX NEG” DIP switch on (shown above).
The wiring diagram on page 14 shows two connection examples
The Park Kill (Cutout) Input turns off any siren tone output when activated, and
remains off until a control is activated or changed. The wiring diagram on page
14 shows two connection examples.
Connecting the white wire to positive (+12 VDC) normally activates the Park
Kill input. To have it activate instead when the white wire is connected to
ground (negative).
1. Turn “PK POS” DIP switch off.
2. Turn “PK NEG” DIP switch on.
(See Amp ifier diagram above)
Park Kill Inp t Polarity

-5-
(Installer Selectable Options CONT’D)
Two-Tone
Phaser Disable
If desired, the Phaser sound can be replaced with a Two-Tone sound. This can
be done by turning on (up position) DIP switch #3 in the amplifier (labeled SW).
(See Amp ifier diagram above)
If desired, the Phaser function can be completely disabled by turning on (up
position) DIP switch #4 in the amplifier (labeled PD). This will also disable the
manual button while the siren is in Phaser mode (which normally would
produce a Two-Tone sound).
(See Amp ifier diagram above)

-6-
(Installer Selectable Options CONT’D)
P rs it Disable (Siren)
The farthest right slide switch position (L3) will normally activate the siren
output in the wail mode, along with all three light functions. Automatic
activation of the siren and arrow stick can be disabled. If you prefer to NOT
have the siren and arrow stick automatically activated when the slide switch is
moved to position three, move Dip switch #2 in the amplifier (labeled PS) to the
“UP” position. (See diagram above).

-7-
CONTROL HEAD OPTION JUMPERS
The control heads are shipped with the standard features listed below. The seven
jumpers are all installed across both pins when the siren is shipped. By moving
the jumpers onto only one pin the alternate operation may be selected. (S3 Auto
Activation is achieved by removing the "Momentary" and "Normally Closed"
jumpers and placing one of them across both of the first pins.)
(Installer Selectable Options CONT’D)
Standard Feature Movin Jumper to One Pin Only
Auxiliary wire activates orn Function Auxiliary wire activates Manual
Function
S4 is a standard push-on/push-off switch S4 closes for 8 seconds when pushed
S3 is a standard push-on/push-off switch S3 becomes a momentary switch
S3 is normally open when off S3 becomes closed when off
ands Free function off when powered up ands Free function is on when unit
powered up
orn Ring Transfer (S5) is off when powered up orn Ring Transfer is auto selected on
start-up
Audible beep heard when buttons are pressed Audible beep disabled
S3 functions activated only with S3 switch S3 functions activated when slider in
L2 or L3 positions
Amplifier Cover Removal
Remove the four Philip head screws recessed in the back of the control head unit.
CAREFULLY remove rear cover, use caution so as not to lift circuit board and
membrane switch away from front faceplate. Locate the 7 jumpers located near
the microphone coil cord strain relief.

-8-
(Installer Selectable Options CONT’D)
A xiliary control (Man al vs. Horn) - The green auxiliary wire in the siren
amplifier harness is typically connected to the vehicle horn, and normally
provides remote activation of the air horn for all siren modes except Hands
Free (HF) mode. In the HF mode, the auxiliary wire will make the siren step
through from Standby to Wail to Yelp to Phaser. The auxiliary wire may be
optionally selected to duplicate the Manual push button instead of the Horn.
8 second timed g n lock release (S4) - The amplifier is shipped with the fourth
push button (S4) as a standard on/off button. It can be optionally selected to
stay activated for only 8 seconds when pressed.
Momentary replacement of lock-on/lock-off switch operation (S3) - The
amplifier is shipped with the third push button (S3) as a standard lock-on/
lock-off switch. It can be changed to momentary operation, thus only being
active while being pressed in.
Normally open contact replacement of normally closed switch (S3) - The
amplifier is shipped with the third push button (S3) as a normally open
contact, which closes when pressed. It can be changed to a normally closed
contact that opens when pressed.
Activate Hands Free on start- p - If you wish to have the siren automatically
activated in Hands Free Mode when the control head is powered up, you can
select this option.
Activate Horn Ring Transfer on start- p (S5) - If you wish to have the fifth
push button (S5) automatically activated when the control head is powered
up, you can select this option. S5 may be connected to the horn ring transfer
relay if you wish to turn the Horn Ring Transfer feature on and off. (Refer to
the wiring diagram on page 14).
A dible beep disable - The audible beep heard when the buttons in the
control head are pressed can be disabled.
S3 A to Activate – S3 will turn on when the slide switch is in positions L2 &
L3 and then will turn off when the switch is moved back to L1 or off.
These two jumpers are shown
moved from their default
position to only one pin.
- Auxillary control
- 8 Second (S4)
- Momentary (S3)
- Normally closed contact (S3)
- ands Free on start up
- orn Ring Transfer on start up
- Audible beep disable
S3 Auto Activate -
place one jumper
over both these
pins
Inhaltsverzeichnis