GFA ELEKTROMAT SE 15.48-25,40 Bedienungsanleitung

Installation Instructions
ELEKTROMAT SE 15.48-25,40
NOT DEFINED
Model: 10004112 10006
-en-
Status: 25.11.2019

2
GfA ELEKTROMATEN UK Ltd
Titan Business Centre
Spartan Close
Warwick CV34 6RR
United Kingdom
www.gfa-elektromaten.co.uk

3
Table of contents
1General safety information .............................................................................................. 4
2Technical Data ................................................................................................................ 5
3Mechanical installation .................................................................................................... 6
4Electrical installation ..................................................................................................... 10
5Limit switch adjustment ................................................................................................. 11
6Motor connection .......................................................................................................... 12
7Alternative motor connection ......................................................................................... 12
8Limit switch connection ................................................................................................. 13
9Emergency manual operation (hand chain operator) ..................................................... 14
10Completing commissioning / inspection ......................................................................... 16
11Declaration of incorporation / Declaration of conformity ................................................. 18
Symbols
Warning - Potential injury or danger to life!
Warning - Danger to life from electric current!
Note - Important information!
▶ Requirement - Required action!
Schematic representations are based on product examples. Deviations from delivered
products are possible.

4
1General safety information
Specified normal use
The drive unit is intended for sectional doors with full counter-balancing.
The safe operation is only guaranteed with normal specified use. The drive unit is to be
protected from rain, moisture and aggressive ambient conditions. No liability for damage
caused by other applications or non-observance of the information in the manual.
Modifications are only permitted with the agreement of the manufacturer. Otherwise the
Manufacturer’s Declaration shall be rendered null and void.
Safety information
Installation and initial operation tasks are to be performed by trained, skilled fitters only.
Only trained electrical craftsmen are permitted to work on electrical equipment. They must
assess the tasks assigned to them, recognise potential danger zones and be able to take
appropriate safety measures.
The installation is only to be carried out with the supply off.
Observe the applicable regulations and standards.
Coverings and safety devices
Do not operate unless corresponding coverings and safety devices are fitted/installed.
Ensure that gaskets are correctly positioned and cable glands are correctly tightened.
Spare parts
Use only original spare parts.

5
2Technical Data
Type SG 63
Output torque 150 Nm
Output speed 48 rpm
Output shaft / hollow shaft 25,40 mm
Maximum output speed open / close
for frequency inverter operation 48 / 48 rpm
Supply voltage 3~ 400 V
Operating current 1,90 A
Operating frequency 50 Hz
Power factor cos φ 0,54
Maximum movement per hour 12 h-1
Hand forces 87 N
Class of protection IP 65
Limit switch range
(maximum revolutions of output shaft / hollow shaft) 40
Braking torque 9 Nm
Braking voltage 103-130 V DC
Rectifier type EGR 230/103
Temperature range -10 / +40 (+60) °C
1) When using a temperature range of +40°...+60°C use half of maximum movements per hour.

6
3Mechanical installation
Prerequisites
The permissible loads on walls, fastenings, mountings and transmission elements must not
be exceeded, even for maximum holding torques or locking torques (▶ refer to technical
data).
Connection elements
▶ Self-locking connection
elements with a minimum
strength of 800 N/mm2
(8.8) must be used.
▶ Utilize the hole diameter
to the full.
▶ Use adequately
dimensioned washers for
elongated holes.
BAGAB00002_Z002
BAGAB00003_Z002
3 : 1
Permissible mounting positions
BAGAC02002_Z002

7
Mounting
Eight threads are provided for mounting (①).
A key is used to connect to the door shaft.
▶ Use a key that is at least as long as the hollow shaft (②).
BAGAD02003_Z002

8
Installation
The descriptions below apply to general door specifications. The specifications of the door
manufacturer must also be observed during installation.
Warning - Potential injury or danger to life!
During installation, be sure to use a lifting device that has a sufficient load-
carrying capacity.
▶ Thoroughly grease the door shaft.
▶ Mount the keys. Pay attention to the
possible versions Ⓐ or Ⓑ.
BAGAE02003_Z002

9
▶ Attach the drive unit.
BAGAE02005_Z002
▶ Tighten all connection elements (M8) to 25
Nm. Install all other connection elements
according to the specifications of the door
manufacturer.
BAGAE02009_Z002
25 Nm
▶ Secure the keys (version Ⓑ only).
BAGAE02012_Z003

10
4Electrical installation
Warning - Danger to life from electric current!
Switch the mains OFF and check that the cables are de-energised
Observe the applicable regulations and standards
Make a proper electrical connection
Use suitable tools
Performing electrical installation
Remove the cover. Insert the motor plug. Insert the limit switch plug.
BAH AA0 3 _ Z 0 0 1
BAHAC13_Z001
Completing the electrical installation
Mount the cable entries and/or cable glands.
Inhaltsverzeichnis
Andere GFA Torantrieb Handbücher