Grizzl-E EV Charging Station – Mini Edition
The Grizzl-E Mini Edition is the smallest, most versatile, portable EV charging station available
on the market, made in Canada and built to withstand the toughest elements.
The Grizzl-E Mini Edition comes exclusively with a sleek, portable design and the ability
to set maximum amperage via Wi-Fi connection. Internal design and components of the
charger have been selected to provide maximum operational life of the device and be able to
withstand the elements.
Grizzl-E Mini provides up to 10 KW of power to your vehicle and can be set to multiple current
ratings for 240V and 120V outlets.
IMPORTANT SAFETY INSTRUCTIONS
This document contains instructions and warnings that must be followed when installing
and using the GRIZZL-E Mini Electric Vehicle Supply Equipment (EVSE). Before installing or
using the EVSE, read this document including any WARNING and CAUTION symbols.
Warning: risk of personal injury
Warning: risk of electric shock
Warning: risk of fire
Caution: risk of damage to equipment
The symbols used have the following meaning:
• This document provides instructions for the charging station and should not be used for
any other product. Before installation or use of this product, review this manual carefully
and consult with a licensed contractor, licensed electrician, or trained installation expert to
ensure compliance with local building codes and safety standards.
• Consult a licensed electrician to ensure that you can safely install and use this product.
• Ensure that the materials used, and the installation procedures, follow local building codes
and safety standards.
• The information provided in this manual in no way exempts the user of responsibility to
follow all applicable codes or safety standards.

Contents
OVERALL WARNINGS & CAUTIONS........................................................................... 5
Product Specications .............................................................................................. 6
Introduction and Unpacking ................................................................................... 7
Installation Planning and Service Wiring: .............................................................. 8
Electrical Source Requirements ................................................................................... 8
Grounding Instructions .................................................................................................8
Grizzl-E Mini Multiple Voltage Ratings..........................................................................8
240V Outlet Settings .................................................................................................. 9
Maximum Current Output ............................................................................................ 9
Adjust Maximum Current Through DIP Switches.......................................................9
Adjust Maximum Current Through Web Browser....................................................11
Charging Status Indicators and Buzzers - 240V .......................................................12
120V Outlet Settings ................................................................................................ 13
Adjust Maximum Current Through Web Browser....................................................13
To set the Maximum Current ....................................................................................13
Charging Status Indicators and Buzzers - 120V .......................................................14
Charger Error Modes and Troubleshooting .......................................................... 15
Check EVSE Status ........................................................................................................15
EVSE Status....................................................................................................................16
Self-Monitoring and Recovery (Auto Restart) ...........................................................16
Troubleshoot EVSE Errors............................................................................................16
EasyEvPlug Holster and Cable Management System .......................................... 18
Operation ................................................................................................................. 19
Connect and Charge ....................................................................................................19
Stop Charging ...............................................................................................................19
General Product Care and Use Information ........................................................ 20
Warranty................................................................................................................... 21

5
CAUTION: The service wiring in this section are specific to North
America only. Before installing the Charging Station, identify the
type of utility service connection onsite. If unsure about the type of
connection available at the service panel, contact your utility service
provider.
Repair and Maintenance Clause
• All United Chargers products do not require routine maintenance however, periodic
inspections should be conducted to ensure that all parts remain in good working order
and no damage exists.
• Do not attempt to open, disassemble, repair, tamper with, or modify any components of
the products. Contact United Chargers for any repairs.
• Read all the instructions before using this product.
• Children should not use this device.
• Do not put fingers into the EV connector.
• Do not touch live electrical parts.
• Do not use this product if the flexible power cord or EV cable is ragged, has broken
insulation, or any other signs of damage.
• Improper connection of the equipment grounding conductor can result in a risk of electric
shock. Check with a licensed electrician if you are in doubt as to whether the product is
properly connected and grounded.
OVERALL WARNINGS & CAUTIONS
Basic precautions should always be followed when using electrical products,
including the following:
WARNING: This equipment is intended only for charging vehicles
that do not require ventilation during charging. Please refer to your
vehicle’s owner’s manual to determine ventilation requirements.

6
Product Specications
United Chargers GRIZZL-E™ Electric Vehicle Charging Station (EVSE)
Description Specications
Model Number GRM-14-24-PB
Connector EVSE Level SAE J1772; AC Level 2
Electrical Circuit / Input Power
Requirements
Dedicated Single Phase 208-240VAC 50/60 Hz. Branch
Breaker: Double pole
OR
Dedicated Single Phase 110-120VAC 50/60 Hz.
Output Ratings 240V Outlet
40A; 9.6kW with 50A Circuit Rating
32A; 7.68kW with 40A Circuit Rating
24A; 5.76kW with 30A Circuit Rating
16A; 3.84kW with 20A Circuit Rating
120V Outlet
15A; 1.8kW with 18A Circuit Rating
12A; 1.44kW with 15A Circuit Rating
10A; 1.2kW for 12A Circuit Rating
8A; 0.96kW for 10A Circuit Rating
Input Power Connection Plug in NEMA 14-50
Installation Rating NEMA 4, Indoor/Outdoor Rated
Operational Ratings Temperature -22F to 122F (-30C to 50C)
Humidity: 95% non-condensing
Overall Dimensions Length: 175mm (6.9in)
Width: 80mm (3.1in)
Height: 60mm (2.4in)
Display and Indicators LED Charge Status Indicator
(Amperage Setting, Ready/Charging, Charging Fault)
Charge Cable Length 24ft (7.3m)

7
Introduction and Unpacking
EasyEVPlug
Holster
Phillips Head Screws
(x4)
Anchor (x4)
MINI
Charging Station with Input and Output Cable

8
Grizzl-E Mini Multiple Voltage Ratings
Grizzl-E Mini has the ability to work with either a 240V or 120V dedicated circuit.
Grizzl-E Mini will automatically detect the outlet power and will adjust settings when the input
cable is plugged into the outlet.
To use Grizzl-E Mini with 120V outlet, use a NEMA 5-15P Male to 14-50R Female, 120V 15A
Adapter.
Installation Planning and Service Wiring:
CAUTION: To reduce the risk of fire, connect only to a circuit
provided with the minimum branch circuit overcurrent
protection requirements in accordance with the National
Electrical Code ANSI/NFPA 7- and the Canadian Electrical Safety
Code, Part 1, C22.1. If you are unsure if your circuit meets these
requirements consult a licensed electrician.
Grounding Instructions
The charging station must be implemented equipment grounding through a permanent
wiring system or an equipment grounding conductor. Use a cable with a dedicated grounding
conductor connected to the equipment ground terminal block.
Prior to using Grizzl-E Mini ensure the electrical source that can support the following Input
Requirements for the Charging Station Per local Electrical Safety Code requirements:
• 240VAC or 120VAC Dedicated Circuit
• A Double Pole Circuit Breaker of the circuit rating must be used.
• The Charging Unit has a built in GFCI protection; do not provide any additional GFCI
protection upstream of the charging unit.
Electrical Source Requirements

9
240V Outlet Settings
Maximum Current Output
The GRIZZL-E Mini charging station features the ability to adjust the maximum current output.
Requirements govern that only 80% of the circuit rated load may be utilized. The Grizzl-E Mini
can support current output of 50A, 40A, 30A, or 20A Dedicated Circuit ratings as follows:
Circuit Rating Maximum Charging Station Output
50A 40A (9.6 kW)
40A 32A (7.68 kW)
30A 24A (5.76 kW)
20A 16A (3.84 kW)
At 240V the Maximum Current Output is governed by the DIP switches on the PCB.
The DIP switch is a 3-position switch located at the top of the PCB.
Adjust Maximum Current Through DIP Switches

10
DOWN DOWN
DOWN
DOWNDOWN
UP
UP
Maximum Current Output DIP 1 DIP 2 DIP3 DIP Switch Setting
40A Maximum Current Output
(Factory Default Setting)
32A Maximum Current Output
24A Maximum Current Output
16A Maximum Current Output
Down
DOWNDOWN
UP UP
To adjust the Maximum Current Output Setting DIP Switches:
1. Ensure the Charging station is unplugged. Place the Charging Station on a at surface with
the front cover facing up.
2. Use a Phillips Head screwdriver to remove the front cover by removing the 4 screws at
each corner of the charging station.
3. Using a non-conductive object adjust the Maximum Current Output using the following
combination of DIP switch settings:
4. Replace the enclosure lid by tightening the 4 screws at each corner
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Grizzl-E Akkuladegerät Handbücher

Grizzl-E
Grizzl-E Ivy Home Bedienungsanleitung

Grizzl-E
Grizzl-E United Chargers GRS-14-24-P Bedienungsanleitung

Grizzl-E
Grizzl-E United Chargers GRS-6-24-P Bedienungsanleitung

Grizzl-E
Grizzl-E United Chargers GRS-14-24-P Bedienungsanleitung

Grizzl-E
Grizzl-E GR1-6-18-R Montage- und Bedienungsanleitung

Grizzl-E
Grizzl-E Mini GRM-14-24-PB Bedienungsanleitung

Grizzl-E
Grizzl-E Smart Connect Classic Montage- und Bedienungsanleitung

Grizzl-E
Grizzl-E Extreme Edition Montage- und Bedienungsanleitung

Grizzl-E
Grizzl-E DUO Montage- und Bedienungsanleitung

Grizzl-E
Grizzl-E DUO GCD-14-24-P Montage- und Bedienungsanleitung