GST GST-IFP8 Bedienungsanleitung

GST-IFP8 USER MANUAL

2
Notice
This instructions covered in this manual have been carefully checked for accuracy and are presumed
to be correct. However, the manufacturer assumes no responsibility for inaccuracies and reserves the
right to modify and revise this document without notice.
This manual covers the installation, programming and commission of the GST IFP8 Fire Alarm
Control Panels.

3
Contents
Preface EN 54 Information................................................................................................................. 4
Introduction ........................................................................................................................................ 5
Installation .......................................................................................................................................... 6
System Lay-out................................................................................................................................... 8
Main Power Lay-out............................................................................................................................ 9
Main Control Board .......................................................................................................................... 10
Terminal Connection ........................................................................................................................ 10
Device Addressing ............................................................................................................................11
Control Panel and Indication........................................................................................................... 13
Description of Controls.................................................................................................................... 14
Zone Indication Panel ...................................................................................................................... 15
System Commissioning................................................................................................................... 16
Commission Mode .......................................................................................................................... 16
How to register a devices/Auto Learn ............................................................................................. 16
How to check duplicated address and device mismatch................................................................. 17
How to modify the device address .................................................................................................. 17
How to modify the device sensitivity ............................................................................................... 18
System Programming ...................................................................................................................... 19
How to program the device detail.................................................................................................... 19
How to encode the text ................................................................................................................... 19
How to program the zone................................................................................................................ 20
How to program the equation.......................................................................................................... 21
How to edit the device type............................................................................................................. 22
System Browsing ............................................................................................................................. 23
To view the device detailed ............................................................................................................. 23
To view the zone (INPUT) assignment............................................................................................ 24
To view the group (OUTPUT) assignment ...................................................................................... 24
To view the duplicated address....................................................................................................... 25
To view the panel status.................................................................................................................. 25
To view the C&E Equation .............................................................................................................. 25
To view the system history .............................................................................................................. 26
SET-UP OPTION................................................................................................................................ 26
To set-up the clock .......................................................................................................................... 26
To set-up the printer ........................................................................................................................ 26
To set-up the delay mode................................................................................................................ 26
To set-up the local outputs .............................................................................................................. 27
SYSTEM OPERATION....................................................................................................................... 28
Dependency Mode/ Pre-alarm ........................................................................................................ 28
Test Mode ....................................................................................................................................... 29
START/STOP OPTION ................................................................................................................... 29
DISABLE/ENABLE OPTION........................................................................................................... 30
Maintenance...................................................................................................................................... 31
System Menu .................................................................................................................................... 32
Lists of Device Type and Condition ................................................................................................ 36
Appendix 4...................................................................................................................................... 38
Operation Following an Alarm or Fault Condition......................................................................... 39

4
Preface EN 54 Information
The GST IFP8 is an Intelligent Fire Alarm Control Panel complies with the latest requirement of EN
standard.
GST-IFP8 Intelligent Fire Alarm Control Panel (FACP) complies with the requirements of EN 54-2
1997 + A1: 2006 and EN 54-4 1997 + A1: 2002 + A2: 2006.
Option EN 54-2 Clause
Indication Alarm counter 7.13
Fault signals from points 8.3
Control
Delays to outputs 7.11
Dependencies on more than one alarm signal 7.12
Disablement of addressable points 9.5
Outputs
Output to fire alarm devices 7.8
Control of fire alarm routing equipment 7.9
Output to fire protection equipment 7.10
Test Test condition 10
The power supply of GST-IFP8 FACP complies with EN 54-4 requirements.
EN 54-4 Clause
Power supply from the main power source 5.1
Power supply from the standby power source (battery) 5.2
Charger 5.3
Faults 5.4
In addition to functions required by EN54-2, the panel supports a number of ancillary functions that
are not required. These are outlined below:
Ancillary Function Manual Section
SP-E32PK Printer 3.2.2
RS232/USB Output 2.3 & 3.2.2
GST852RP Repeater Panel 3.3.6
GstDef2.1 Defining Tool 3.4
Fire Alarm Output 4.4.3.3
RS485 Output 2.3 & 4.4.3.5

5
Introduction
The GST-IFP8 is an intelligent fire alarm control panel. Flush-mounted type housing it provides the perfect
solution for all medium to large system by utilizing advance GST Protocol.
The system is compatible with the complete range of GST Intelligent detectors, Sounders, Call Points, and
Interfaces, including intrinsically safe and gaseous extinguishing control. IFP8 is manufactured and
certified to EN54 parts 2 and 4 and to BS5839 Par 4.
8 x Loops (242) capacity (1936) addressable points
Maximum 10 Loops Standalone
Modular constructed for future expansion
40 x15 lines Colour Graphical LCD Display.
Up to 999 programmable zones and 140 zone indication
Auto Programming Day and Night Mode
Enable and Disable function
PAS and Acknowledge Function
Dirty Detector Reporting
Duplicate Address Checking
Walk Test Function with optional silent mode
Can edit device detailed and programmed
Programmable form PC or Panel
History record-999 fire incident only and 999 event capacity in non-volatile memory Fully simulation of
Cause and Effect
Advanced user friendly programming software including ‘Fuzzy Logic’.
Networked with all GST Intelligent Fire panels up to 99 Nodes, Optional Fiber Optic and LAN Network
Interface.
RS 485 mimic and repeater output up 64
RS 232-USB CRT interface, including GSTGMC graphic
Built in Fire Alarm, FPE, Fault and Alarm Router output
Panel Printer included
Built in Battery charger.

Instal
l
Installati
o
inside t
h
wrist str
a
electroni
Before u
Open th
e
K
e
l
ation
o
n of the p
a
h
e panel ar
e
a
p designe
d
c circuit bo
a
npacking a
n
e
IFP8 Con
t
Magnetic
Door Lock
e
y Door Loc
k
a
nel should
e
vulnerable
d
to preven
t
a
rds.
n
ything, ple
a
t
rol Panel, u
k
be carried
to damage
t
the buil-u
p
a
se review
a
nlock and p
Loca
t
Main Doo
r
Outer
Glass Do
o
out by train
by electro
s
p
of static
c
a
ll the manu
rop the hin
g
t
ing the hin
g
r
or
ed personn
s
tatic disch
a
c
harges whi
al and dra
w
g
ed door.
g
e pin
Back Box
el only. Th
e
a
rges. It is r
e
thin the bo
d
w
ing.
e
electronic
e
commend
e
d
y, before
h
Locating th
e
6
component
s
e
d to wear
a
h
andling an
y
e
hinge pin
6
s
a
y

7
Locate and placed the panel and marked the three holes for mounting.

8
System Lay-out
Main Control Board
Main Power
Board
AC Filter Power Switch
Zone Indication Board Printer
AC/DC Power Converter
Main Indication Board

9
Main Power Lay-out
Standby Batteries
Maximum Charge Current: 2A±0.1A
Maximum Charge Voltage: 27.3V±0.3V
Type: Sealed lead acid batteries
Maximum Charge Capacity: Two 12V/38Ah batteries
Recommended manufacturer and model of battery: Yuasa NP38-12I
Maximum Internal Resistance: 0.7Ω
Quiescent Current under Full-loaded Condition: 1.4A
Maximum Operating Current: 4.2A
Recommended Cable: GST fire cable

10
Main Control Board
Warning:
Use static precautions when handling boards, grounding wrist strap and contact with chassis.
Setting the card address
Numbering sequence, lower card is the
recommended lowest numerical setting. Set
dials on the additional board in ascending order.
Each card must be set at least one higher digit
than the lower card.
Terminal Connection
CARD SUM: 03 LOOP SUM: 04 SUM:0000
*****************************************
LOOP 1: Loop Card, Devices Sum: 000
LOOP 2: Loop Card, Devices Sum: 000
LOOP 3: Loop Card, Devices Sum: 000
LOOP 4: Loop Card, Devices Sum: 000
LOOP 5: Net Card-01, Net Sum: 01
LOOP 6: CRT CARD -01
Press F1 to print LOOP DEVICES info
Andere Handbücher für GST-IFP8
1
Inhaltsverzeichnis
Andere GST Feueralarm Handbücher

GST
GST DC-9102E Bedienungsanleitung

GST
GST DI-9204Exd Bedienungsanleitung

GST
GST I-9202 Bedienungsanleitung

GST
GST GST-MNA2C Bedienungsanleitung

GST
GST DI-9406 Bedienungsanleitung

GST
GST DC-9204E Bedienungsanleitung

GST
GST C-9401 Bedienungsanleitung

GST
GST DI-9204 Bedienungsanleitung

GST
GST DI-9204 Bedienungsanleitung

GST
GST DC-M9415 Series Montageanleitung