GAS FIREBRICK INSERT SPECIFICATIONS
Dimensions above are in inches. Reference dimensions only. We recommend measuring individual units at installation. NOTE: Combustible material should not be installed over the face. Make sure you do NOT cover
the decorative door opening.
Refer to installation manual for detailed specifications on installing this product. Heat & Glo reserves the right to update units periodically. The flame and ember appearance may vary based on the type of fuel
burned and the venting configuration used. Pictures in this brochure are not a true representation of the fireplace and/or flames.
LEFT SIDE
VIEW
TOP
VIEW
RIGHT SIDE
VIEW
FRONT
VIEW
MODEL
FRONT WIDTH BACK WIDTH HEIGHT DEPTH
GLASS SIZE BTU/Hour
Input (NG)
UNIT
MIN.
FIREBOX
OPENING
UNIT
MIN.
FIREBOX
OPENING
UNIT
MIN.
FIREBOX
OPENING
UNIT
MIN.
FIREBOX
OPENING
ESCAPE-I35,
ESCAPE-I35LP
34-3/4
[882]
35
[889]
25-1/4
[641]
25-1/2
[648]
24-5/8
[626]
2 4 - 7/ 8
[632]
17
[432]
18-1/4
[464]
31-1/2 x 20
[800 x 508] 20,000 - 40,000
ESCAPE-I30,
ESCAPE-I30LP
30
[762]
30-1/4
[768]
21-1/4
[552]
21-1/2
[546]
22-9/16
[573]
22-7/8
[581]
15-5/8
[397]
16-7/8
[429]
26-3/4 x 18
[679 x 457] 17,000 - 36,000
MODEL A B C D E F G
ESCAPE-I35, ESCAPE-I35LP
25-1/4 [641] 34-3/4 [864] 31-1/2 [800] 20 [508] 24-5/8 [626] 21-11/16 [551] 17 [432]
ESCAPE-I30, ESCAPE-I30LP
21-1/4 [552] 30 [762] 26-3/4 [679] 18 [457] 22-9/16 [573] 19-15/16 [506] 15-5/8 [397]
*For full warranty details, go to www.heatnglo.com.
Fireplace glass and other surfaces get extremely HOT and
can cause severe burns if touched. Do not remove the
protective safety screen from the front of the glass. Keep a
safe distance away. To learn more visit
www.heatnglo.com/fireplacesafety
HNG-1095U-1014
Web: heatnglo.com
Phone: (888) 427-3973 (952) 985-6000
E-mail: info@heatnglo.com
facebook.com/HeatandGlo
twitter.com/HeatandGlo
youtube.com/HeatandGlo
For complete information on this model,
please contact us at:
LIMITED LIFETIME WARRANTY*
The strongest in the industry, Heat & Glo provides
a limited lifetime warranty on the most important
aspects: firebox and heat exchanger.
U.S. EFFICIENCIES
Steady State - Since most homeowners use their fireplaces for an extended time while they are in the room, Steady
State measures how efficiently your fireplace converts fuel to heat once it is warmed up and running in a “steady state”.
AFUE - AFUE rating is more typically used with appliances, like your furnace, that continually cycle on and off to
maintain a constant temperature.
RATING ESCAPE-I35 ESCAPE-I35LP ESCAPE-I30 ESCAPE-I30LP
Steady State 85.8% 86.0% 85.8% 85.5%
AFUE 73.1% 73.8% 70.1% 70.0%
RATING ESCAPE-I35 ESCAPE-I35LP ESCAPE-I30 ESCAPE-I30LP
EnerGuide
(CSA P.4.1-02) 72.9% 73.8% 68.8% 69.3%
CANADA EFFICIENCIES
EnerGuide (CSA P.4.1-02) - EnerGuide is a rating used in Canada to measure annual fireplace efficiency.