4Heatilator • SC60 Installation Manual • 4013-281 • Rev F • 05/06/15
WARNING! Risk of Fire! Hearth & Home Technologies
disclaims any responsibility for, and the warranty and
agency listing will be voided by the following actions.
DO NOT:
• installoroperatedamagedreplace
• modifyreplace
• install other than as instructed by Hearth & Home
Technologies
• operate the fireplace without fully assembling all
components
• overre
• installunventedgaslogset
• installanycomponentnotapprovedbyHearth&Home
Technologies
• installpartsorcomponentsnotListedorapproved
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualied
installer, service agency or your dealer.
B. Non-Combustible Materials
• Materials which will not ignite and burn, composed of
any combination of the following:
- Steel - Iron
- Brick - Tile
- Concrete - Slate
- Glass - Plasters
• Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace at 750° C
C. Combustible Materials
• Materials made of or surfaced with any of the following
materials:
- Wood - Compressed paper
- Plant bers - Plastic
- Plywood/OSB - Sheet rock (drywall)
• Any material that can ignite and burn; ame proofed or
not, plastered or un-plastered
D. Electrical Codes
NOTICE: This replace must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code ANSI/
NFPA 70-latest edition or the Canadian Electric Code
CSA C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in damp locations.
1 Product Specic & Important Safety Information
A. Fireplace Certication
This replace may be installed in sleeping rooms EX-
CEPT in manufactured homes. If installed with a gas log
set, provisions for the National Fuel Gas Code must be
met.
This replace has been tested and listed for use with
the optional components specied in this manual. These
optional components may be purchased separately and
installed at a later date. An outside air kit, gas log set or
gas log-lighter should be installed at the time of replace
installation.
Heatilator is a registered trademark of Hearth & Home
Technologies.
This replace system has been tested and listed in accor-
dance with UL 127 and ULC-S610 standards by Under-
writers Laboratories Inc. for installation and operation in
the United States and Canada.