U.S. Patent No. 8,856,780
MODULE DIAGNOSTICS - 1 OF 1
TEST MODULE
LED 1 STATUS
DIAGNOSTIC
I DURING MODULE PROGRAMMING
Flashing RED Missing/wrong information from firmware or vehicle.
Solid RED Module waiting for more vehicle information.
Flashing GREEN Additional steps required to complete module programming.
Solid GREEN then OFF Module correctly programmed.
OFF No activity or module already programmed.
II DURING TACH PROGRAMMING
1 GREEN flash Tach signal programmed in Analog
2 GREEN flashes Tach signal programmed in Data
3 RED flashes No tach signal detected
4 RED flashes System is in valet mode
5 RED flashes Tach set for ‘VTS’. No tach programming required
6 RED flashes Tach set for ‘assumed start’. No tach programming required
III DURING REMOTE START
Flashing RED Module incorrectly programmed.
Solid RED Module incorrectly programmed.
Flashing GREEN Module correctly programmed and operational.
Solid GREEN then OFF Reset in progress.
OFF Invalid ground when running status from remote starter.
IV WITH IGNITION OFF
Flashing RED Module incorrectly programmed or connected.
Solid RED Module not programmed. Waiting for more vehicle information.
Flashing GREEN False ground when running status from remote starter.
Solid GREEN then OFF Reset in progress.
OFF Module at rest and ready for a remote start sequence.