MuteClip®Installation Guide Wall
To Stud Wall
Instructions
• Install a Stud wall 5mm off the original wall.
+600mm centres for the stud vertical structs with sucient noggins to strengthen the structure.
• Insert Acoustic Mineral Wool between the stud frame.
+Acoustic Mineral Wool can be friction-held between the joists/battens, if required use thin wiring to keep it
suspended.
• Measure up and mark out the appropriate locations for the MuteClips (See congurations or contact iKoustic for
appropriate dimensions).
+The perimeter MuteClips must be no further than 100mm from the adjacent surfaces.
• MuteClips to be spaced a maximum of 600mm apart vertically.
MuteClip to Stud Frame
1st Plasterboard to Channel
2nd Plasterboard to Channel
MuteClip Channel Overlap
5mm x 60mm Wood Screw
32mm Fine Thread Dry Wall Screw
50mm Fine Thread Dry Wall Screw
20mm Steel Self-Tapping Screw
Fixings
-
-
-
-
Suitability of xings to be conrmed by installer.

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
3
+MuteClip centres to vary betwen 600 and 1200m centres creating a Diamond conguration.
• Attach MuteClip Channels into MuteClips, channels should run horizontally.
+MuteClip Channels must overlap by 200mm, x 4 self-tapping screws into the shoulders of the MuteClip
Channels to give a secure join.
• MuteClip Channels should not overlap on a MuteClip.
• Fix your rst layer of Acoustic Plasterboard to the MuteClip Channels.
+Acoustic Plasterboard must not be in direct contact with any adjacent surfaces. There should be a 2-5mm gap
around the perimeter of the surface.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Adhere Tecsound to the Acoustic Plasterboard using Tecsound’s self-adhesive backing.
+It may be easier to cut Tecsound into manageable sized pieces for ease of installation.
• Fix your second layer of Acoustic Plasterboard, stagger the joist from the rst layer, making sure that the screws go
into the MuteClip Channels.
+Again, leave a 2-5mm gap around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Scrim tape all joins and nish with a skim plaster.
Congurations
Please contact iKoustic to conrm correct congurations appropriate for your system.
If you need any assistance, please call us on 01937 588 226.
Standard Diamond

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
4
MuteClip®Installation Guide Wall
Direct to Wall
Instructions
• Measure up the wall being treated and mark out the locations for the MuteClips (See congurations or contact
iKoustic for appropriate dimensions).
+The perimeter MuteClips should be no further than 100mm from the adjacent surfaces.
• Hammer x screw directly into brickwork to secure the MuteClip.
+Drill hole in the wall, plug this hole and x the screw through the Clip into the hole.
• MuteClips to be spaced a maximum of 600mm apart vertically
+MuteClip centres to vary betwen 600 and 1200m centres creating a Diamond conguration (See congurations
or contact iKoustic for appropriate dimensions).
• Attach MuteClip Channels into MuteClips, channels must run horizontally.
MuteClip Direct to Wall
1st Plasterboard to Channel
2nd Plasterboard to Channel
MuteClip Channel Overlap
Hammer Fix Plug & Screw
32mm Fine Thread Dry Wall Screw
50mm Fine Thread Dry Wall Screw
20mm Steel Self-Tapping Screw
Fixings
-
-
-
-
Suitability of xings to be conrmed by installer.

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
5
+MuteClip Channels must overlap by 200mm, x 4 self-tapping screws into the shoulders of the MuteClip
Channels to give a secure join.
• MuteClip Channels should not overlap on a MuteClip.
• Insert Acoustic Mineral Wool between/behind the MuteClip Channels.
• Fix your rst layer of Acoustic Plasterboard to the MuteClip Channels.
+Acoustic Plasterboard must not be in direct contact with any adjacent surfaces. There must be a 2-5mm gap
around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Adhere Tecsound to the Acoustic Plasterboard using Tecsound’s self-adhesive backing.
• It may be easier to cut Tecsound into manageable sized pieces for ease of installation.
• Fix your second layer of Acoustic Plasterboard and stagger the joins from the rst layer, making sure that the
screws go into the MuteClip Channels.
+Again, leave a 2-5mm gap around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Scrim tape all joins and nish with a skim plaster.
Congurations
Please contact iKoustic to conrm correct congurations appropriate for your system.
If you need any assistance, please call us on 01937 588 226.
Standard Diamond

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
6
When installing a MuteClip system around a Door or Window, a piece of channel should be installed above each door
and window to ensure the plasterboard is supported along the edge.
Perimeter Details
MuteClip®Installation Guide Wall
Windows, Doors, Openings and Pitched Ceilings
Windows and Doors
Please contact iKoustic to conrm correct congurations appropriate for your system.
If you need any assistance, please call us on 01937 588 226.
MuteClip® Stud System
Window - Side View
MuteClip® Stud System
Door - Top View
MuteClip® Direct to Wall System
Window - Side View
MuteClip® Direct to Wall System
Door - Top View

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
7
When installing a MuteClip system on a pitched roof use one section of channel supported by
clips along the slanted side to ensure the plasterboard is supported along the edge.
MuteClip®Installation Guide Wall
Windows, Doors, Openings and Pitched Ceilings
Pitched Ceilings
Please contact iKoustic to conrm correct congurations appropriate for your system.
If you need any assistance, please call us on 01937 588 226.
MuteClip Channel must not be installed over any opening or vent in your wall or ceiling system. To overcome this, install
a MuteClip and MuteClip Channel section above the opening or vent. This will help support the weight of the system.
Vents and Openings

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
8
MuteClip®Installation Guide Ceiling
Direct to Concrete Ceiling
Instructions
• Measure up the ceiling you will be treating and mark out the locations for the clips (See congurations or contact
iKoustic for appropriate dimensions).
+The perimeter MuteClips should be no further than 100mm from the adjacent walls.
• Securely anchor bolt the MuteClips directly into the concrete ceiling at the appropriate centres (See congurations
or contact iKoustic for appropriate dimensions).
• Attach MuteClip Channels into MuteClips.
+MuteClip Channels should overlap by 200mm, x 4 self-tapping screws into the shoulders of the channels to
give a secure join.
• MuteClip Channels should not overlap on a MuteClip.
• Insert Acoustic Mineral Wool behind the MuteClip Channels.
MuteClip to Concrete Substrate
1st Plasterboard to Channel
2nd Plasterboard to Channel
MuteClip Channel Overlap
Anchor Bolt
32mm Fine Thread Dry Wall Screw
50mm Fine Thread Dry Wall Screw
20mm Steel Self-Tapping Screw
-
-
-
-
Fixings
Suitability of xings to be conrmed by installer.

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
9
• Fix your rst layer of Acoustic Plasterboard to the MuteClip Channels.
+Acoustic Plasterboard must not be in direct contact with any adjacent surfaces. There must be a 2-5mm gap
around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Adhere Tecsound to the Acoustic Plasterboard using Tecsound’s self-adhesive backing.
+It may be easier to cut Tecsound into manageable sized pieces for ease of installation.
• Fix your second layer of Acoustic Plasterboard and stagger the joins from the rst layer, making sure that the
screws go into the MuteClip Channels.
+Again, leave a 2-5mm gap around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Scrim tape all joins and nish with a skim plaster.
Congurations
Standard Diamond
Please contact iKoustic to conrm correct congurations appropriate for your system.
If you need any assistance, please call us on 01937 588 226.

iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
10
Instructions
• Measure up the ceiling you will be treating and mark out the locations for the battens (See congurations or contact
iKoustic for appropriate dimensions).
• Apply MuteStrip or Isolation Strip to the side of the timber that will be in direct contact with the ceiling.
• Ensuring the timber frame is at appropriate centres, securely anchor bolt the timber frame to the ceiling.
• Mark out the locations for the MuteClips (See congurations or contact iKoustic for appropriate dimensions).
+The perimeter MuteClips must be no further than 100mm from the adjacent walls.
• Screw MuteClips into the appropriate joists.
• Attach MuteClip Channels into MuteClips, channels must run perpendicular to the joists/battens.
+MuteClip Channels must overlap by 200mm, x 4 self-tapping screws into the shoulders of the MuteClip
Channels to give a secure join.
MuteClip®Installation Guide Ceiling
Direct to Battened Concrete Ceiling
Battens to Concrete
MuteClip to Battens
1st Plasterboard to Channel
2nd Plasterboard to Channel
MuteClip Channel Overlap
Anchor Bolt
5mm x 60mm Coarse Thread Wood Screw
32mm Fine Thread Dry Wall Screw
50mm Fine Thread Dry Wall Screw
20mm Steel Self-Tapping Screw
Fixings
Suitability of xings to be conrmed by installer.
-
-
-
-
-