Inficon IO1000 Bedienungsanleitung

Type designation
Product description
INSTALLATION MANUAL
Catalog no.
from software version
Document no.
560-310
I/O module 1.0
jiqc10en1-b (1301)
IO1000
I/O module

2
This document applies to the software version stated on the cover page. If you need
a different version, please contact our sales staff.
Reprint, translation and duplication need to be approved in writing by
INFICON GmbH.

Content 3
Content
1 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Target groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Other applicable documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Presentation of information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3.1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3.2 Text markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 User requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3 User requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Shipment check, transport, storage . . . . . . . . . . . . . . . . 7
3.1 Checking shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1 Construction of the I/O module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.3.1 Mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.3.2 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.3.3 Ambient conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Installation and removal . . . . . . . . . . . . . . . . . . . . . . . . 15
5.1 Mounting of I/O module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.1.1 Establish connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2 Removing the I/O module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4About this manual
1 About this manual
1.1 Target groups
This installation manual is intended for the operator and for technically qualified
personnel with experience in leak detection technology and integration of leak
detection devices in leak detection systems. In addition, the installation and use of
the unit require knowledge of electronic interfaces.
1.2 Other applicable documents
1.3 Presentation of information
1.3.1 Warnings
Installation manual for mass spectrometer module jiqa54
Interface protocols jira54
Imminent threat of danger resulting in death or severe injuries
Dangerous situation potentially resulting in death or severe injuries
Dangerous situation resulting in minor injuries
Dangerous situation resulting in damage to property or the environment

About this manual 5
1.3.2 Text markings
Marking Meaning
Requirement for execution of an action
Tool or aid for an action
►Instruction
1, 2, 3, ... Several instructions in a fixed order
Result of an action
SMALL CAPS Designation of the unit or command/term from the menu
Information Useful tips and information

6Safety
2Safety
2.1 Intended use
The I/O module is a device interface between the MSB box of the mass spectrometer
module LDS3000 and an external controller, for example.
►Install, operate and service the unit only in compliance with this manual.
►Comply with the limits of application (see Chapter 4.3, page 14).
2.2 User requirements
Safety conscious operation
►Operate and install the unit only if it is in perfect working order and as intended,
in a safety-conscious manner and fully aware of dangers, in compliance with this
manual.
►Fulfill and ensure compliance with the following regulations:
– Intended use
– Generally applicable safety and accident prevention regulations
– International, national and local standards and guidelines
– Additional provisions and regulations that are specific to the unit
►Use only original parts or parts approved by the manufacturer.
►Keep this manual available at the operating site.
Personnel qualifications
►All work must be performed only by technical specialists who have been trained
on the unit.
►Allow personnel in training to work with the unit only under the supervision of
technical specialists.
►Make sure that the authorized personnel have read and understood this manual
and all other applicable documents (see Chapter 1.2, page 4), especially the
information on safety, maintenance and repairs, before starting work.
►Define responsibilities, authorizations and supervision of personnel.
2.3 User requirements
►Read, observe and follow the information in this manual and the working
instructions created by the owner, especially the safety instructions and warnings.
►Perform all work based on the complete manual.

Shipment check, transport, storage 7
3 Shipment check, transport, storage
3.1 Checking shipment
Scope of delivery
►Check shipment to make sure it is complete.
3.2 Transport
3.3 Storage
►Always store the unit in compliance with the technical data, see Chapter 4.3,
page 14.
Article Quantity
I/O module 1
Installation manual 1
Damage due to unsuitable packaging material
Transport in unsuitable packaging material can damage the unit.
►Transport the unit only in the original packaging material.
►Keep original packaging material.

8Description
4 Description
4.1 Construction of the I/O module
1 - PLC IN
Digital inputs
Electrical insulation (max. 60 V DC, 25 V AC against GND)
Max. permissible input voltage: U = 35 V
Active signal: U = 13 ... 35 V (typically 24 V), I = approx. 7 mA
Inactive signal: U < 7 V (typically 0 V), I = 0 mA
Fig: 1 Front view
Fig: 2 Digital inputs
PLC-IN PLC-IN
1 Dyn CAL / Normal Cal
1 Dyn CAL / Normal Cal
2 SNIFF / VAC
2 SNIFF / VAC
3 STOP
4 ZERO
5 EXT.CAL
6 INT.CAL
7 CLEAR
8
9
10
11 PLC-IN-GND
3 STOP
4 ZERO
5 EXT.CAL
6 INT.CAL
7 CLEAR
8
9
10
11 PLC-IN-GND
24V-OUT
+
_
0 V
24 V
0 - 24V
PLC/SPS
PLC/SPS

Description 9
Connection plug arrangement
The digital inputs can be freely configured.
►For other layouts, see installation manual for mass spectrometer module
LDS3000.
Key-operated switch
An external key switch with up to three switching outputs can be connected via three
PLC inputs. The key switch can be used to select the access level of the user of the
control unit.
Key 1 - Operator
Key 2 - Supervisor
Key 3 - Integrator
Example for a suitable key switch: Hop + Schuler, No. 444-05
2- RS232
Connection for RS-232
Electrical insulation (max. 60 V DC, 25 V AC against GND)
Connection plug arrangement
A normal RS-232 cable must be used for the connection (1:1 connection, RxD and
TxD not crossed, no zero-modem cable).
►Deactivate RS-232 hardware handshake in RS-232 control program.
Pin Name Factory setting mass spectrometer module
1 PLC-IN 1 Dyn CAL / Normal Cal
2 PLC-IN 2 SNIFF/VAC
3PLC-IN3 STOP
4PLC-IN4 ZERO
5 PLC-IN 5 EXT.CAL
6 PLC-IN 6 INT.CAL
7 PLC-IN 7 CLEAR
8PLC-IN8 -
9PLC-IN9 -
10 PLC-IN 10 -
11 PLC-IN-COM COM
Pin Name
2TxD
3RxD
5GND

10 Description
If the hardware handshake cannot be deactivated, then the RS-232 cable can be
used as follows:
3 - STATUS
Status LED
4 - ANALOG OUT
Analog outputs (for logging leakage rate and backing pressure)
Electrical insulation (max. 60 V DC, 25 V AC against GND)
Connection plug arrangement
The analog outputs can be freely configured.
►For other layouts, see installation manual for mass spectrometer module
LDS3000.
Fig: 3 Connection with RS-232 cable (in case hardware handshake cannot be
deactivated)
Color Status Meaning
Red illuminates Unit not functional or defective
Red flashes Not ready for operation, communication to mass
spectrometer module is not available
Cyan illuminates Ready for operation; communication to mass
spectrometer module available
Green Flashes quickly Boot loader active, ready for software update
Green Flashes slowly Data reception on RS232
Yellow Flashes slowly Data reception on RS485
Voltage range 0...10V
Precision ±15 mV offset, additional ±1% from measurement (current
output voltage) as linearity error (at 25 °C)
Resolution typ. 2.5 mV
Load >10kΩ
Pin Name Factory setting mass spectrometer module
1 ANALOG-OUT 1 Leak rate mantissa
1 ... 10 V; linear; in used unit
2 ANALOG-OUT 2
Leak rate exponent
1 ... 10 V; 0.5 V / decade; step function;
1 V = 1 x 10-12; in used unit
3 ANALOG-OUT-GND -
Andere Handbücher für IO1000
3
Inhaltsverzeichnis
Andere Inficon E/A-System Handbücher
Beliebte E/A-System Handbücher anderer Marken

WAGO
WAGO 750-344 Bedienungsanleitung

Teknim
Teknim TWM-1887 Bedienungsanleitung

Intelligent Appliance
Intelligent Appliance IA-2662-E Bedienungsanleitung

BERGHOF
BERGHOF ECC DIO 16/16 Bedienungsanleitung

Advantech
Advantech PCM-27J3AU Installations- und Betriebshandbuch

Festo
Festo CP-E08-M12-CL Bedienungsanleitung