3. BUILDING STANDARDS & REGULATIONS
This appliance must be installed in accordance with the current editions of:
• Building Standards (Scotland) (Consolidation) Regulations.
• Building Regulations
• Gas Safety (Installation and Use) Regulations (as amended)
• BS 7671 Institute of Electrical Engineers (I.E.E) Wiring Regulations
• BS 6891 Installation of Low Pressure Gas Pipework of up to 28 mm
(R1) in domestic premises (2nd family gases).
• BS 5440 Pt. 1 (Flues for Gas Appliances)
• BS 5440 Pt. 2 (Air Supply for Gas Appliances)
• Model and Local Authority Byelaws
• BS 5546 Installation of Domestic Hot Water Supplies
This appliance has been Tested and Certified in order to meet the necessary
European Directives and comply with the latest Building Regulations,
including the efficiency requirements of the SEDBUK scheme.
Efficiency of Hot Water Boilers Directive 92/42/EEC
Gas Appliance Directive 90/396/EEC
Low Voltage Directive 93/68/EEC
Electromagnetic Compatibility Directive 92/31/EEC
No modifications to this appliance should be made, unless they are fully
approved by the manufacturer.
The manufacturers instructions supplied must not be taken as overriding any
statutory requirements.
A two year manufacturers warranty applies to this appliance.
It is important that the system is flushed thoroughly before the applianceIt is important that the system is flushed thoroughly before the appliance
is left to operate (as recommended in BS 7593) in order to maintain an
efficiently operating heating system. For replacement installations, the
system MUST be flushed with the old boiler in situ, in order to prevent the
RenoXtra becoming a trap for system debris. Once the system has been
flushed, an inhibitor (suitable for stainless steel heat exchangers) should be
added. Appropriate inhibitors are available, for example Sentinel, Fernox and
Salamader.
Failure to carry out the above procedure will invalidate the
guarantee!
IMPORTANT: STATUTE LAW DEFINES THAT ALL GAS
APPLIANCES MUST BE INSTALLED BY COMPETENT
PERSONS, (i.e. GAS SAFE REGISTERED INSTALLERS) IN
ACCORDANCE WITH THE GAS SAFETY (INSTALLATION
AND USE) REGULATIONS (CURRENT EDITION). FAILURE
TO COMPLY WITH THESE REGULATIONS MAY LEAD TO
PROSECUTION.
4. SAFETY & GAS INFORMATION
4.1 SAFETY INFORMATION
4.1.1 Ensure the mains supply voltage, frequency, number of phases and
power rating comply with details on the rating label.
4.1.2 All wiring must be in accordance with the appropriate standards. The
equipment must be supplied with a double pole isolator switch.
4.1.3 Ensure safety regulations and practices are adhered to when installing
and using this equipment
4.1.4 The weight of this appliance exceeds that recommended for a one-
man lift. It will therefore be necessary to gain assistance at
times during the installation procedure.
4.1.5 It should be noted that this appliance may contain sharp edges. Care
MUST be taken when handling the appliance to prevent injury. We
advise the engineer to wear suitable P.P.E.
4.1.6 Once the appliance has been fired beware that certain parts will be hot
to the touch.
4.1.7 Do not install flues during rain, high winds or in severe weather
conditions.
www.johnsonandstarley.co.uk
4