Kilsen KFP-CX3E Series Bedienungsanleitung

KFP-CX3E Series
Installation Manual
P/N 501-419403-1-10 • REV 01 • ISS 12MAR14

Copyright
©
2014 UTC Fire & Security. All rights reserved.
Trademar
ks and
patents
KFP
-CX3E Series is a trademark of UTC Fire & Security.
Other trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the
respective prod
ucts.
Manufacturer
UTC CCS Manufacturing Polska Sp. Z o.o.
Ul. Kolejowa 24. 39
-100 Ropczyce, Poland
Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert,
Netherlands
Version
This document covers control panels with firmware version 2.0 or
later
.
Certification
European Union
directives
1999/5/EC (R&TTE directive): Hereby, UTC Fire & Security declares
that this device is in compliance with the essential requirements and
other relevant provisions of Direc
tive 1999/5/EC.
2002/96/EC (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new
equipment, or dispose of it at
designated collection points. For more information see:
www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that
cannot be disposed of as unsorted municipal waste in the European
Union. S
ee the product documentation for specific battery
information. The battery is marked with this symbol, which may
include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to your supplier or to a
desig
nated collection point. For more information see:
www.recyclethis.info.
Contact information
For contact information, see www.utcfssecurityproducts.eu
.

KFP-CX3E Series Installation Manual i
Content
Important information ii
Chapter 1 Introduction 1
Product description 2
Product compatibility 2
Operating modes 2
Chapter 2 Installation 3
Control panel cabinet layout 4
Cabinet installation 5
Connections 7
Chapter 3 Configuration and commissioning 23
The user interface 25
User levels 26
Configuration overview 27
Basic configuration 31
Advanced configuration 37
Expansion board configuration 60
Fire network and repeaters configuration 62
Commissioning 70
Chapter 4 Maintenance 75
System maintenance 76
Battery maintenance 77
Chapter 5 Technical specifications 79
Zone specifications 80
Input and output specifications 81
Power supply specifications 83
Mechanical and environmental specifications 84
Appendix A Configuration presets 87
Input and output configuration 88
Default delays 88
Basic configuration modes 89
Expansion board functions 91
Appendix B Regulatory information 99
European standards 100
Declared performance 101
Electrical safety 101
Index 103

ii KFP-CX3E Series Installation Manual
Important information
This is the installation manual for the KFP-CX3E Series Extinguishing and Fire
Alarm Control Panels. Read these instructions and all related documentation
entirely before operating this product.
Firmware compatibility
Information in this document covers control panels with firmware version 2.0 or
later. This document must not be used as a guide to installation, configuration, or
operation of control panels with an earlier firmware version.
For instructions on how to check the firmware version of your control panel, see
“Configuration, software, and PCB identification” on page 59.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described
below.
WARNING: Warning messages advise you of hazards that could result in injury
or loss of life. They tell you which actions to take or to avoid in order to prevent
the injury or loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell
you which actions to take or to avoid in order to prevent the damage.
Note: Note messages advise you of the possible loss of time or effort. They
describe how to avoid the loss. Notes are also used to point out important
information that you should read.
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be
liable for any lost profits or business opportunities, loss of use, business
interruption, loss of data, or any other indirect, special, incidental, or
consequential damages under any theory of liability, whether based in contract,
tort, negligence, product liability, or otherwise. Because some jurisdictions do not
allow the exclusion or limitation of liability for consequential or incidental
damages the preceding limitation may not apply to you. In any event the total
liability of UTCFS shall not exceed the purchase price of the product. The
foregoing limitation will apply to the maximum extent permitted by applicable law,
regardless of whether UTCFS has been advised of the possibility of such
damages and regardless of whether any remedy fails of its essential purpose.

KFP-CX3E Series Installation Manual iii
Installation in accordance with this manual, applicable codes, and the instructions
of the authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to
ensure the accuracy of its contents, UTCFS assumes no responsibility for errors
or omissions.

iv KFP-CX3E Series Installation Manual

KFP-CX3E Series Installation Manual 1
Chapter 1
Introduction
Summary
This chapter provides an introduction to your control panel and the available
operating modes
Content
Product description 2
Product compatibility 2
Operating modes 2

Chapter 1: Introduction
2 KFP-CX3E Series Installation Manual
Product description
The KFP-CX3E Series control panel provides three fire detection zones (Z1, Z2,
and Z3) and several manual call point (MCP) and control inputs that control the
extinguishing actions for a single extinguishing area.
If a fire detection zone is not configured as part of the extinguishing detection
area, the control panel provides standard fire panel functionality for that fire
detection zone (for example, the panel activates fire sounders, fire routing, and
other auxiliary outputs).
Product compatibility
Products compatible with this control panel are listed in the supplied compatibility
list. Compatibility with products that are not listed in that document cannot be
guaranteed. For further details contact your local supplier.
Note: The CleanMe self-diagnostics feature listed in selected presets is not
available for KFP-CX3E Series devices.
Operating modes
Supported operating modes are shown in the table below. The default operating
mode is EN 54-2 (with EN 54-13 supervision disabled).
Table 1: Operating modes
Operating mode
EN 54-13 option [1] Region
EN 54
-2 (default) Yes [2] European Union
BS 7273
No United Kingdom
Repeater
with fire routing (EN 54-2)
No
European Union
Repeater
with fire routing (BS 7273)
No
United Kingdom
[1] EN 54
-13 supervision requires compatible system wiring and devices and must be enabled by
the installer in the control panel configuration.
[2] EN 54-13 supervision is available in zones and expansion board outputs.

KFP-CX3E Series Installation Manual 3
Chapter 2
Installation
Summary
This chapter explains how to install your control panel, how to connect zones, fire
and extinguishing system devices, and the power supply.
Note: This product must be installed and maintained by qualified personnel
adhering to the CEN/TS 54-14 standard (or the corresponding national standard)
and any other applicable regulations.
Content
Control panel cabinet layout 4
Cabinet installation 5
Preparing the cabinet 5
Where to install the cabinet 5
Fixing the cabinet to the wall 5
Connections 7
Recommended cables 7
Connecting zones with initiating devices 7
Connecting inputs 10
Connecting outputs 14
Connecting the mains power supply 17
Connecting the batteries 18
Connecting other equipment 19
Connecting expansion boards 20
Connecting a fire network 20

Chapter 2: Installation
4 KFP-CX3E Series Installation Manual
Control panel cabinet layout
Figure 1: Control panel cabinet layout
1. Seven-segment display
2
. Zone, input, output, and relay connectors
3
. Cable knockouts
4
. Mounting screw knockouts
5
. Network board connector (on the back of
the PCB)
6
. Battery area
7. Power supply unit
8
. Key connector (see note)
9
. Fuse terminal block
10
. Power supply connector
11
. Battery connector
12
. Expansion board connector
13. Cable holder
Note: The control panel is available with a key option. The key switch is located
on the panel cover. With this option, either the key or the password can be used
to enter the operator user level. This key can also be configured to be used in
manual-only or manual-automatic mode.
Andere Handbücher für KFP-CX3E Series
1
Inhaltsverzeichnis
Andere Kilsen Bedienfeld Handbücher

Kilsen
Kilsen KFP-CX3 Bedienungsanleitung

Kilsen
Kilsen KFP-AF Series Bedienungsanleitung

Kilsen
Kilsen KFP-CE4 Series Bedienungsanleitung

Kilsen
Kilsen KFP-CX3E Series Bedienungsanleitung

Kilsen
Kilsen KFP-AF Series Bedienungsanleitung

Kilsen
Kilsen KFP-AE1(-S) Bedienungsanleitung

Kilsen
Kilsen KFP-CX3 Bedienungsanleitung