KNX GIRA 5065 00 Bedienungsanleitung

Dimming actuator 1-gang 200 W with binary input, 3-gang
Table of Contents
1 Safety instructions.............................................................................................................3
2 Device components...........................................................................................................4
3 Function ............................................................................................................................5
4 Information for electrically skilled persons ........................................................................7
4.1 Mounting and electrical connection........................................................................ 7
4.2 Commissioning ...................................................................................................... 9
5 Technical data.................................................................................................................11
6 Troubleshooting ..............................................................................................................13
7 Accessories.....................................................................................................................15
8 Warranty..........................................................................................................................15
2 / 15
82404412 02.12.2022

1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled
persons.
Serious injuries, fire or property damage possible. Please read and follow manual
fully.
Danger of electric shock. Device is not suitable for disconnection from supply voltage
because mains potential even is applied on the load when the output is switched off.
Always disconnect before carrying out work on the device or load. To do so, switch
off all associated circuit breakers.
Danger of electric shock. Make sure during the installation that there is always suffi-
cient insulation between the mains voltage and the bus. A minimum distance of at
least 4 mm must be maintained between bus conductors and mains voltage cores.
Danger of electric shock on the KNX installation. Do not connect any external voltage
to the inputs. The device might be damaged, and the SELV potential on the KNX bus
line will no longer be available.
Fire hazard. For operation with inductive transformers, each transformer must be
fused on the primary side in accordance with the manufacturer's instructions. Only
safety transformers according to EN 61558-2-6 may be used.
Risk of destruction of the dimmer and load if the set operating mode and load type do
not match. Set the correct dimming principle before connecting or exchanging the
load.
This manual is an integral part of the product, and must remain with the end cus-
tomer.
3 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

2 Device components
Image1: Device components
(1) Programming LED
(2) Programming button
(3) Control cable (KNX connection and extension inputs)
(4) Load connection (dimming output)
Image2: Connection assignment of control cable (example)
red (RD) KNX +
black (BK) KNX -
green (GN) Input 1 (push-button, switch, contact, condensation/leakage sensor)
yellow (YE) Input 2 (push-button, switch, contact, condensation/leakage sensor)
white (WH) Input 3 (push-button, switch, contact, condensation/leakage sensor,
NTC temperature sensor)
brown (BN) COM inputs 1...3
4 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

3 Function
System information
This device is a product of the KNX system and complies with the KNX directives.
Detailed technical knowledge obtained in KNX training courses is a prerequisite to
proper understanding.
The function of this device depends upon the software. Detailed information on load-
able software and attainable functionality as well as the software itself can be ob-
tained from the manufacturer´s product database.
The device can be updated. Firmware can be easily updated with the Gira ETS Ser-
vice App (additional software).
The device is KNX Data Secure capable. KNX Data Secure offers protection against
manipulation in building automation and can be configured in the ETS project. De-
tailed specialist knowledge is required. A device certificate, which is attached to the
device, is required for safe commissioning. During mounting, the device certificate
must be removed from the device and stored securely.
Planning, installation and commissioning of the device are carried out with the aid of
the ETS, version 5.7.3 and above.
Intended use
– Operating in KNX systems
– Switching and dimming of lighting
– Reading in switching states of installation switches or push-buttons and other
potential-free contacts at inputs 1...3
– Signal evaluation of condensation and leakage sensors at inputs 1...3 (see ac-
cessory).
– Acquisition of temperature values via NTC temperature sensor at input 3 (see
accessories)
– Mounting in appliance boxes according to DIN 49073
Product characteristics
– Outputs can be operated via KNX telegrams or extension inputs
– Three extension inputs for connecting potential-free contacts or dew/leakage
sensors. NTC temperature sensor can be connected to input 3.
– Supply via KNX, no additional power supply necessary
– KNX Data Secure compatible
– Updatable with Gira ETS Service App
Dimming operation characteristics
– Automatic or manual selection of the dimming principle suitable for the load
– Protected against no-load, short-circuit and overheating
5 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

– Signal in the event of a short-circuit
– Feedback of the switching position and the dimming value
– Parameterisable switch-on and dimming behaviour
– Time functions: switch-on delay, switch-off delay, staircase lighting timer with
run-on time
– Light scene operation
– Operating hours counter
– Mains failure longer than approx. 5 seconds leads to switch-off of the dimming
actuator. Depending on the parameter setting, the connected load is calibrated
after mains voltage return.
– Power extension possible by means of power boosters.
Delivery state: Operation of the output via extension inputs 1 and 2 possible
with existing supply via KNX.
Flickering of the connected lamps due to undershoot of the specified minimum
load or through centralised pulses from the power stations. This does not rep-
resent any defect in the device.
Extension input characteristics
– Switching operating function
– Dimming operating function (incl. colour temperature dimming)
– Shutter/Venetian blinds operating function
– Value transmitter operating function (1-byte, 2-byte, 3-byte and 6-byte incl.
RGBW and colour temperature presets)
– Scene extension operating function
– 2-channel operation operating function
– Controller extension operating function
– Disabling functions
– Debounce time adjustable
Logic function characteristics
– Logic gate
– Transformer (conversion)
– Disabling element
– Comparator
– Limit value switch
6 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

4 Information for electrically skilled persons
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
4.1 Mounting and electrical connection
DANGER!
When connecting the bus/extensions and mains voltage wires in a shared appliance
box, the KNX bus line may come into contact with the mains voltage.
This endangers the safety of the entire KNX installation. People at remote devices
may also receive an electric shock.
Do not place bus/extensions and mains voltage terminals in a shared connection
compartment. Use an appliance box with a fixed partition wall or separate appliance
boxes.
Connecting and fitting the device
In secure operation (preconditions):
– Secure commissioning is activated in the ETS.
– Device certificate entered/scanned or added to the ETS project. A high resolu-
tion camera should be used to scan the QR code.
– Document all passwords and keep them safe.
Mounting in suitable appliance box (recommendation: electronic device box with par-
tition). Observe cable routing and spacing (see figure 3)!
7 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

Image3: Mounting example in electronic appliance box with partition wall, series
push-button and NTC temperature sensor
(5) Appliance box
(6) Partition
(7) potential-free contacts (e.g. series push-button)
(8) NTC temperature sensor (optional)
Image4: Cable spacing
Minimum spacing between the mains voltage and bus/extension wires: 4 mm
(see figure 4)
Image5: Connection of load
8 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

Observe ambient temperature. Ensure adequate cooling.
■ Connect the device to KNX with the correct polarity.
■ Connect load as shown in the connection example (see figure 5).
■ If required, connect potential-free contacts or condensation/leakage sensors to
inputs 1...3, or NTC temperature sensors to input 3 (see figure 2).
■ Install the device in the appliance box.
■ In secure operation: The device certificate must be removed from the device
and stored securely.
The COM reference potential must not be connected together with COM con-
nections of other devices!
4.2 Commissioning
Commissioning the device
In the as-delivered state, the actuator is passive, i.e. no telegrams are transmitted to
the KNX. The output is set to the universal dimming principle with automatic recogni-
tion of the load type. Control of the output is possible via inputs 1 and 2, provided the
bus voltage is switched on. Input 3 has no function.
Function of Inputs in the as-delivered state
Input Push-button (NO con-
tact)
Function
1 Press briefly (< 0.4 s) Switch on
1 Press for a long time (>
0.4 s)
Increase brightness
2 Press briefly (< 0.4 s) Switch off
2 Press for a long time (>
0.4 s)
Reduce brightness
3 --- ---
The device can be programmed and put into operation via the ETS. The physical ad-
dress is preset to 15.15.255.
Moreover the device has been configured at the factory with the following character-
istics...
– Behaviour in case of bus voltage failure: no reaction
– Behaviour in case of bus voltage return: brightness before bus voltage failure
Load physical address and application program
■ Parameterise correct dimming principle for the connected load.
■ Press the programming button.
The programming LED lights up.
■ Load physical address and application program using the ETS.
9 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang

Safe-state mode
The safe-state mode stops the execution of the loaded application program.
Only the system software of the device is still functional. ETS diagnosis func-
tions and programming of the device are possible.
Activating safe-state mode
■ Switch off the bus voltage or disconnect the device from the KNX.
■ Wait about 10 s.
■ Press and hold down the programming button.
■ Switch on the bus voltage or connect the device to KNX. Release the pro-
gramming button only after the programming LED starts flashing slowly.
The safe-state mode is activated.
By briefly pressing the programming button again, the programming mode can
also be switched on and off in the safe-state mode as usual. If the program-
ming mode is active, the programming LED stops flashing.
Deactivating safe-state mode
■ Switch off bus voltage (wait approx. 10 s) or carry out ETS programming.
Master reset
The master reset restores the basic device settings (physical address 15.15.255,
firmware remains in place). The device must then be recommissioned with the ETS.
In secure operation: A master reset deactivates device security. The device can then
be recommissioned with the device certificate.
Performing a master reset
Precondition: The safe-state mode is activated.
■ Press and hold down the programming button for > 5 s.
The programming LED flashes quickly.
The device performs a master reset, restarts and is ready for operation again
after approx. 5 s.
Restoring the device to factory settings
Devices can be reset to factory settings with the Gira ETS Service App. This function
uses the firmware contained in the device that was active at the time of delivery (de-
livered state). Restoring the factory settings causes the devices to lose their physical
address and configuration.
10 / 15
82404412 02.12.2022
Dimming actuator 1-gang 200 W with binary input, 3-gang
Inhaltsverzeichnis
Andere KNX Controller Handbücher

KNX
KNX Iddero Verso Bedienungsanleitung

KNX
KNX GIRA Bedienungsanleitung

KNX
KNX GIRA Bedienungsanleitung

KNX
KNX Module SAS-04.16 Bedienungsanleitung

KNX
KNX GIRA Bedienungsanleitung

KNX
KNX Jung 230011SU Bedienungsanleitung

KNX
KNX Jung 2304.16 REG HE Bedienungsanleitung

KNX
KNX GIRA 2015 00 Bedienungsanleitung

KNX
KNX Berker 7531 40 18 Bedienungsanleitung

KNX
KNX GIRA Standard Bedienungsanleitung