Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Notes to Users
We appreciate you purchasing a Koolsola Solar Air Conditioning System. With your purchase you will
enjoy the bene its o power savings and a ordable com ort or many years to come.
To understand how your Koolsola Solar Air Conditioning System works and to ensure the best
per ormance rom your System please read the ollowing in ormation be ore installing or using the
system.
1) The Koolsola Solar Air Conditioning System must be installed by a quali ied, licensed Air
Conditioning Installer.
2) The ‘Installation Guide’ section on this manual is speci ically or quali ied, licensed Air
Conditioning Installers to re er to whilst carrying out installation.
3) Please ensure that you read the ‘Operating Instructions’ section o this manual be ore using
your system.

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Contents
1. General Information
1.1. System Speci ications Page 5
1.2. Sa ety In ormation Page 9
1.3. System Operating Principles Page 10
1.4. System Components Page 11
2. Operating Instructions
2.1. General Operating Instructions Page 13
2.2. Remote Control Function Page 14
2.3. Routine Maintenance Page 18
2.4. Troubleshooting Page 21
3. Installation Guide
3.1. General Installation In ormation Page 25
3.2. Indoor Unit Installation Page 28
3.3. Outdoor Unit Installation Page 30
3.4. Evacuate Tube Solar Collector Installation Page 31
3.5. Flat Panel Solar Collector Installation Page 34
3. . Gassing Installation Page 36
3.7. Wiring Installation Page 39

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Section 1
General Information

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
1.1
System Specifications
Koolsola TKFR-2 GW
Rated Cooling Capacity (Watts) 2600
Rated Heating Capacity (Watts) 2900
Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz
Rated Cooling Power Input (Watts) 650 – 770
Rated Cooling Input Current (Amperes) 2.95 – 3.50
Maximum Cooling Power Input (Watts) 962
Maximum Cooling Input Current (Amperes) 4.38
Rated Heating Power Input (Watts) 650 – 780
Rated Heating Input Current (Amperes) 2.95 – 3.55
Maximum Heating Power Input (Watts) 975
Maximum Heating Input Current (Amperes) 4.44
Auxiliary Electric Heating Rated Power Input (Watts) 600
Auxiliary Electric Heating Rated Input Current (Amperes) 2.73
Inhaling Maximum Working Pressure (Megapascals) 1.15
Exhausting Maximum Working Pressure (Megapascals) 4.1
Type o Re rigerant R-410A
Standard amount o Re rigerant (grams) 800
Air Circulation o Outdoor Unit (Metres cubed/hour) 450
Waterproo Grade 1PX4
Net Weight Outdoor Unit (Kilograms) 30
Net Weight Indoor Unit (Kilograms) 8
Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 790/260/540
Dimensions Indoor Unit (Millimetres – Length/Width/Height) 700/230/160
Noise Level Outdoor Unit (Decibels) < 50
Noise Level Indoor Unit (Decibels) < 40
Parameters in this table are measured in the rated working state o an outdoor temperature o 35oC dry
bulb/24oC wet bulb and an indoor temperature o 27oC dry bulb/19oC wet bulb. Working states at
varying temperatures may change.

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Koolsola TKFR-35GW
Rated Cooling Capacity (Watts) 3500
Rated Heating Capacity (Watts) 3800
Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz
Rated Cooling Power Input (Watts) 800 – 1025
Rated Cooling Input Current (Amperes) 3.64 – 4.66
Maximum Cooling Power Input (Watts) 1280
Maximum Cooling Input Current (Amperes) 5.83
Rated Heating Power Input (Watts) 800 – 1050
Rated Heating Input Current (Amperes) 3.64 – 4.77
Maximum Heating Power Input (Watts) 1310
Maximum Heating Input Current (Amperes) 5.96
Auxiliary Electric Heating Rated Power Input (Watts) 800
Auxiliary Electric Heating Rated Input Current (Amperes) 3.63
Inhaling Maximum Working Pressure (Megapascals) 1.15
Exhausting Maximum Working Pressure (Megapascals) 4.1
Type o Re rigerant R-410A
Standard amount o Re rigerant (grams) 1150
Air Circulation o Outdoor Unit (Metres cubed/hour) 550
Waterproo Grade 1PX4
Net Weight Outdoor Unit (Kilograms) 38
Net Weight Indoor Unit (Kilograms) 10.5
Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 790/260/540
Dimensions Indoor Unit (Millimetres – Length/Width/Height) 785/285/210
Noise Level Outdoor Unit (Decibels) < 52
Noise Level Indoor Unit (Decibels) < 42
Parameters in this table are measured in the rated working state o an outdoor temperature o 35oC dry
bulb/24oC wet bulb and an indoor temperature o 27oC dry bulb/19oC wet bulb. Working states at
varying temperatures may change.

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Koolsola TKFR- 0GW
Rated Cooling Capacity (Watts) 6000
Rated Heating Capacity (Watts) 6600
Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz
Rated Cooling Power Input (Watts) 1350 – 1560
Rated Cooling Input Current (Amperes) 6.14 – 7.09
Maximum Cooling Power Input (Watts) 1950
Maximum Cooling Input Current (Amperes) 8.86
Rated Heating Power Input (Watts) 1350 – 1590
Rated Heating Input Current (Amperes) 6.14 – 7.23
Maximum Heating Power Input (Watts) 2000
Maximum Heating Input Current (Amperes) 9
Auxiliary Electric Heating Rated Power Input (Watts) 1500
Auxiliary Electric Heating Rated Input Current (Amperes) 8.1
Inhaling Maximum Working Pressure (Megapascals) 1.15
Exhausting Maximum Working Pressure (Megapascals) 4.1
Type o Re rigerant R-410A
Standard amount o Re rigerant (grams) 1600
Air Circulation o Outdoor Unit (Metres cubed/hour) 850
Waterproo Grade 1PX4
Net Weight Outdoor Unit (Kilograms) 55
Net Weight Indoor Unit (Kilograms) 21
Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 940/300/755
Dimensions Indoor Unit (Millimetres – Length/Width/Height) 985/325/230
Noise Level Outdoor Unit (Decibels) < 56
Noise Level Indoor Unit (Decibels) < 46
Parameters in this table are measured in the rated working state o an outdoor temperature o 35oC dry
bulb/24oC wet bulb and an indoor temperature o 27oC dry bulb/19oC wet bulb. Working states at
varying temperatures may change.

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Koolsola TKFR-72GW
Rated Cooling Capacity (Watts) 7200
Rated Heating Capacity (Watts) 7900
Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz
Rated Cooling Power Input (Watts) 1700 – 1900
Rated Cooling Input Current (Amperes) 7.73 – 8.64
Maximum Cooling Power Input (Watts) 2375
Maximum Cooling Input Current (Amperes) 10.8
Rated Heating Power Input (Watts) 1700 – 1950
Rated Heating Input Current (Amperes) 7.73 – 8.64
Maximum Heating Power Input (Watts) 2440
Maximum Heating Input Current (Amperes) 10.8
Auxiliary Electric Heating Rated Power Input (Watts) 1800
Auxiliary Electric Heating Rated Input Current (Amperes) 8.18
Inhaling Maximum Working Pressure (Megapascals) 1.15
Exhausting Maximum Working Pressure (Megapascals) 4.1
Type o Re rigerant R-410A
Standard amount o Re rigerant (grams) 1800
Air Circulation o Outdoor Unit (Metres cubed/hour) 1050
Waterproo Grade 1PX4
Net Weight Outdoor Unit (Kilograms) 62
Net Weight Indoor Unit (Kilograms) 19
Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 940/300/755
Dimensions Indoor Unit (Millimetres – Length/Width/Height) 985/325/230
Noise Level Outdoor Unit (Decibels) < 54
Noise Level Indoor Unit (Decibels) < 42
Parameters in this table are measured in the rated working state o an outdoor temperature o 35oC dry
bulb/24oC wet bulb and an indoor temperature o 27oC dry bulb/19oC wet bulb. Working states at
varying temperatures may change.

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Safety Information
Safety Warnings:
The Koolsola Solar Air Conditioning system should only be installed repaired and maintained by
a qualified, licensed air conditioning installer.
Please switch o the power to the system in the event o an electrical storm in order to prevent
damage to the system.
Please switch o the power to the system when it is not in use or long periods o time.
Please switch o the power to the system be ore conducting any cleaning o or maintenance o
the system.
Never clean the system with liquid detergents lique ied cleaning agents or corrosive cleaning
agents. Never allow the indoor unit to come into contact with liquid. Any o these actions may
cause damage to the plastic accessories and casings or cause damage to the electrical
components.
Never insert your hands or any other object into the air outlet o the indoor and outdoor units
to ensure that there is no damage to the high-speed an or the object being inserted.
Never allow children to play the system.
Never remove any o the coverings o the system.
Never allow moisture to get into the remote control.
Never put or use any combustible liquid or substance such as hair spray, paint or petrol near the
machine to prevent the possibility o ire.
I any unusual circumstances occur, including but not limited to; strange noises or smells,
smoke, abnormal temperature increases or changes to appearance o components please
switch o the power immediately and contact your local distributor o the Koolsola Solar Air
Conditioning System. Do not attempt to repair the system yoursel .
Pre-checking before operation:
Please re er to the Section 2.3 – Routine Maintenance to establish the correct method or
cleaning the air ilter and checking/ illing the solar collector with water.
I the system has been switched o /idle or a long period o time please clean the air ilter
be ore turning the system back on.
I the system has been switched o /idle or a long period o time please check the level o the
water in the solar collector and add water i required.
In normal operating conditions please clean the air ilter every 2 weeks.
In normal operating conditions please check the level o the water in the solar collector every 3
months and add water i required.

Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
1.2 System Operating Principles
The Koolsola Solar Air Conditioning System uses both mains electrical power and solar thermal
energy. The Koolsola Solar Air Conditioning System always requires mains electrical power to
operate ans and electrical control components.
The Koolsola Solar Air Conditioning System uses solar thermal energy as an energy source to
help maintain the re rigeration process which in turn reduces the amount o electrical energy
required to run the compressor.
The Koolsola Solar Air Conditioning System operates under the same principles as a
Conventional Air Conditioning System where re rigeration takes place as a result o the phase
transition o the re rigerant.
The di erence between a Koolsola Solar Air Conditioning System and a Conventional System is
how the vapour is changed back into a liquid state in the re rigeration cycle.
A Conventional System uses a compressor to increase the pressure o the re rigerant when it’s
in a vapour state so that when it enters the condenser coil the combination o pressure and
cooling rom ambient air condenses it into a liquid in the coil. The change o state o re rigerant
begins to take place approximately two thirds o the way down the condenser. The Koolsola
Solar Air Conditioning System improves on this basic method by using solar thermal energy
collected in a solar collector to add thermal energy to the re rigerant vapour. By using this
method it reduces the amount o compression required to achieve the re rigeration cycle, as
well as utilising more o the cooling ace o the condenser coil.
By reducing the amount o compression required to achieve the re rigeration process the
Koolsola Solar Air Conditioning System can use an undersized compressor in comparison to a
Conventional System. Similarly i enough solar thermal energy is being collected and utilised the
compressor will run less o ten in a Koolsola Solar Air Conditioning System than a Conventional
System.
The Koolsola Solar Air Conditioning System incorporates o centre an blade technology,
insulated oam ducts and high per ormance brand name compressors to achieve optimum
per ormance at a minimum level o noise. The Koolsola Solar Air Conditioning System typically
creates 10dBA less noise than a Conventional System.