Lead 2FE1-4ETH Series Bedienungsanleitung

Manual of 2FE1-4ETH Protocol Converters Equipment
1
Table of Contents
PREFACE................................................... 2
CHAPTER ONE OVERALL INTRODUCTION ......................... 3
1.1 SUMMARY............................................................................................... 3
1.2 FEATURES OF EQUIPMENT .......................................................................... 3
CHAPTER TWO FUNCTION SPECIFICATION......................... 4
2.1 INTRODUCTION TO FRONT PANEL OF THE DEVICE ............................................. 4
2.2 INTRODUCTION TO THE REAR PANEL OF THE EQUIPMENT..................................... 5
2.3 DIP SWITCH............................................................................................ 5
CHAPTER THREE TECHNICAL SPECIFICATIONS ..................... 7
3.1 OPERATING ENVIRONMENT ......................................................................... 7
3.2 POWER SUPPLY SECTION ........................................................................... 7
3.3 MECHANICAL SPECIFICATIONS ..................................................................... 7
3.4 E1 INTERFACE ......................................................................................... 7
3.5 ETHERNET INTERFACE................................................................................ 7
CHAPTER FOUR WEB SETTING.................................. 8
4.1 WEB MANAGEMENT REQUIREMENTS ............................................................ 8
4.2 WEB LOGIN............................................................................................ 8
4.3 SYSTEM CONFIG ...................................................................................... 9
CHAPTER FIVE ACCESSORIES ................................. 15
5.1 METHOD OF MAKING LINES........................................................................ 15
5.2 WARRANTY CARD................................................................................... 16

Manual of 2FE1-4ETH Protocol Converters Equipment
2
Preface
Version Description
Manual version: V1.0
Copyright Notice
The copyright of this manual is reserved to our company, who retains the final
rights of explanation and revision to this manual and notice. No part of this
manual may be photocopied, excerpted, reproduced, revised, transmitted,
translated into other languages, or used for commercial purpose in full or in part,
without the prior written permission of the Company.
Disclaimer
This manual is made according to currently available information and subject to
change without further notice. Whilst every effort has been made to ensure the
accuracy and reliability of the contents contained herein, the Company cannot
be held liable for any harm or damage resulting from any omissions,
inaccuracies or errors contained in the manual.
Brief Introduction
This User Manual describes the installation and operation of 2FE1-4ETH
Protocol Converters Equipment. Before you use our device for the first time,
please read all the included materials carefully, and install and operate this
series of products in keeping with items listed in the manual, so as to avoid
damaging the device resulting from malpractice. Thank you for choosing our
products.
Environmental Protection
This product complies with the design requirements associated with
environmental protection. The storage, use and disposal of the
product should be conducted in accordance with related national
laws and regulations.
We welcome you to put forward advice and suggestion to our
work, which shall be viewed as the ultimate support to us.

Manual of 2FE1-4ETH Protocol Converters Equipment
3
Chapter One Overall Introduction
1.1 Summary
2FE1-4ETH Interface Protocol Converters are capable to support four
network devices or other devices for remote centralized management. Remote
users can perform centralized management for 2FE1-4ETH series devices by
Telnet, WEB Server or centralized management software. It also can remotely
perform such actions like restart and upgrade the 2FE1-4ETH series devices;
The devices are widely used for remote management of devices room,
servers, routers and other key equipment in the situation of industrial control,
water treatment, radio and television, public facilities and unattended room
management.
1.2 Features of Equipment
Support 220V AC or 48V DC Power Input
Build in intelligent switch fabric, provide 4 fast Ethernet ports
Support packet length up to 2047 Bytes
Provide up to 2K MAC address entries
Support IEEE802.1Q VLAN
Support QinQ double tagging
Support HDLC/PPP-BCP(RFC3518)/GFP-F encapsulation when
1xE1 mode; GFP for 2xE1 mode.
Support E1 frame or un-frame application when select 1xE1 HDLC
mode
GFP-F encapsulation comply with ITU-T G.7041 standard
Support LCAS and VCAT function comply with G.7042 and G.7043
Provide statistics for each ports
Support Console or telnet CLI management
Support SNMP(v1/v2c) and Web management
Support software and firmware upgrade
Support E1 floated or connected to PGND by switch
75Ωand 120Ωimpedances are selected by switch

Manual of 2FE1-4ETH Protocol Converters Equipment
4
Chapter Two Function Specification
2.1 Introduction to Front Panel of the Device
2.1.1 Device Front Panel
Figure1.1 of Front Panel
2.1.2 Front Panel Indicators Specification
There are 9 indicators on the front panel of the device, and their functions are:
2.1.3 Ethernet
Ethernet
1 2 34
ACT SPD
LED
Name
Colors
Functions
Status
Description
PWR
GREEN
Power Indication
on
Power supply normal
off
Power off
WORK
GREEN
Device Work
Status
on
Device working
off
Not working
SYS
YELLOW
System status
flash
System working
LOSA/B
RED
A/B E1 Loss code
alarm
on
A/B E1 Loss code
alarming
off
Normal
LOF/B
RED
A/B E1 Loss
Frame alarm
on
A/B E1 Loss Frame
alarming
off
Normal
AISA/B
RED
A/B E1 ALL 1
alarm
on
A/B E1 ALL 1 alarming
off
Normal
LED Name
Colors
Functions
Status
Description
SPD1~4
GREEN
Ethernet Speed
Rate
on
100M
off
10M
ACT1~4
YELLOW
Ethernet
Connection
Status
flash
Data transmitting
on
Connected
off
Dis-connected

Manual of 2FE1-4ETH Protocol Converters Equipment
5
2.1.4Reset
The system is in normal operation, if continuously press the Reset button
more than 3 seconds, the system will restore factory default configuration and
reboot.
2.1.5Console
The device provides a series of Config commands and command line
interfaces for configuring and managing the device. Local Config
via the Console port.
2.2 Introduction to the rear panel of the equipment
2.2.1 Device Rear Panel
Figure 1.2 of Rear Panel
2.2.2 Rear Panel Specification
Two channels of E1 interface with Q9 (75ohm) or RJ45 (120 ohm)
connectors. 220VAC/48VDC Power Interface with a switch. The second
channel of E1 will be disabled when the device under
HDLC/PPP-BCP/GFP-F single E1 mode.
2.3 DIP Switch
SW1 SW2
1 8 1 16
SW1[1-2]
E1 E1 Impedance
ALL ON
75 ohm
ALL OFF
120 ohm
SW1[3-6]
E1 75 ohm
unbalanced
selection
ALL ON
unbalance
ALL OFF
balance
SW1[7]
E1 75 Ohm
unbalanced
ON
E1 shield grounded
OFF
E1 grounded shielded by

Manual of 2FE1-4ETH Protocol Converters Equipment
6
shielded cable
grounding
connection
connected with discharge
tube
SW2
undefined
undefined

Manual of 2FE1-4ETH Protocol Converters Equipment
7
Chapter Three Technical Specifications
3.1 Operating Environment
The device has a wide range of operating temperature and is able
to work normally and stably in highly adverse environment.
Working Temperature 0℃ ~ +50℃
Storage Temperature -40℃ ~ +70℃
Relative Humidity 10 %~95 %
Atmospheric Pressure 70~106 kpa
The environment should be free from corrosive and solvent gases,
dust, and magnetic interference.
3.2 Power Supply Section
Input Voltage:AC 220V/DC 48V
Voltage Fluctuation:100VAC~240VAC/36VDC~72VDC
Power Consumption:<5 W
3.3 Mechanical Specifications
Appearance dimension: 210mm*143mm*41mm
3.4 E1 Interface
Interface Impedance:75Ω,120Ω
Connector Type: Q9(75Ω),RJ45(120Ω)
3.5 Ethernet Interface
Speed rate: 10M/100M Auto-negotiation、10M half-Duplex、10M Full
Duplex、100M Half-Duplex, 100M Full Duplex Optional.
Support VLAN and QinQ function

Manual of 2FE1-4ETH Protocol Converters Equipment
8
Chapter Four Web setting
4.1 WEB Management Requirements
PC Operating system: Win 2000/Win XP/Win7/Linux
Network Connection:Ethernet/FastEthernet
WEB Browser : IE6 or later version,FireFox,and others.
The PC must be in the same subnet with 2FE1-4ETH.
4.2 WEB Login
We use Internet Explorer as the example.Run the browser
program, input the IP address of 2FE1-4ETH in the address bar
with the prefix “http://“. The default address is 192.168.0.168.
The fowling picture shows the login dialog box, input the
right user name and password. User and password both are "root".
The password of the default user "root" can be modified
through CLI(Command Line Interface) or WEB.

Manual of 2FE1-4ETH Protocol Converters Equipment
9
4.3 System Config
4.3.1 System Info
Software Version: The device software version.
Firmware Version: The device firmware (FPGA) version.
Running Time: The time since the device last boots.
MAC Address: The device mac address.
System Name: The system name. Each device can be
assigned different name.
Dot1Q Vlan Enable : The global 802.1Q vlan function.
Admin Vlan : The Admin Vlan, valid when dot1q vlan is
enabled.
QinQ Enable : The QinQ Function, valid when dot1q vlan is
enabled.
QinQ Ethernet Type : The QinQ ethernet type, valid when
dot1q vlan & qinq enabled.
Ethernet Isolation : The 4 ethernet ports isolation.
Config File : If ‘Save’ option selected, the current
configuration will be saved to the flash. If ‘Erase’ option
selected the saved config will be erased from the flash.

Manual of 2FE1-4ETH Protocol Converters Equipment
10
System Reboot : Reboot the system Immediately without
save, or after save , or to factory settings(by erasing the
saved configuration).
4.3.2 Network Config
IP Address : The device IP Address. (default is
192.168.0.168)
Net Mask : The device netmask.
Default Gateway : The device gateway
4.3.3 E1 Config
Work Mode : 2FE1-4ETH support 4 work mode : HDLC 1*E1
/ PPP 1*E1/ GFP 1*E1 / GFP 2*E1.
Inhaltsverzeichnis