Lec+ Contour Bedienungsanleitung

Contour & Contour LX Pedicure Chairs
USER MANUAL
1-400-0009 • Rev G • 8/28/22
© Living Earth Crafts 2020, All Rights Reserved
*shown with oponal accessories and/or nishes
Contour LX
Contour

© Copyright 2020
Living Earth Cras®
All rights reserved. is document or any
portion thereof may not be reproduced
in any way, including photocopying or
translation to another language without
the prior written permission from Living
Earth Cras.
Living Earth Cras® is a registered trade-
mark of Earthlite Massage Tables, Inc.
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Living Earth Cras®.
Living Earth Cras® assumes no responsibility for the
accuracy or suitability of the information contained in
this document. is document may contain technical
inaccuracies or errors. Living Earth Cras® makes no
expressed or implied warranties of any kind concerning
the information contained in this document, including,
but not limited to, the implied warranties of merchant-
ability and tness for purpose.
Living Earth Cras® shall not be liable for incidental or
consequential damages in connection with or arising out
of the product, performance, or use of this document
and the information and material it describes.

Introduction
Congratulaons on your purchase of the Contour pedicure chair. The Contour oers an
unparalleled pedicure and hydrotherapy experience, featuring a luxurious, handcraed
motorized chair and a tub powered by the patented Sanijet® pipeless jets. The tub basin is lined
with soothing textured foot pebbles to give your client’s feet a relaxed, massaging sensaon.
The Contour is designed for licensed therapists and technicians and is intended to be used in a
professional spa, salon, or similar commercial environment. While no special training is needed
to operate the product, for safety reasons it is important that the instrucons contained in this
manual are reviewed in detail before the rst use. This manual should be read in its enrety by
each professional who will be operang the product to ensure the safety of both operator and
client. This manual should be saved for future reference.
The Contour should not be used in any other manner than described in this manual. Please read,
understand, and follow all safety warnings, labels, and instrucons. Misuse, use of unnecessary
force, or using the chair for unintended or unauthorized procedures can result in injury to
operator, client, and/or equipment.
Detailed instrucons for use and maintenance can be found in this user manual. If you have
further quesons, please contact us at (800) 872-0560 for US customers, or (760) 597-2155 for
internaonal customers. We can also be reached via e-mail at info@livingearthcras.com
Secon 1: Safety Informaon
Safety Symbols/Warnings
Secon 2: Product Overview
Product Diagram
Product Specicaons
Secon 3: Operang Instrucons
Control Panel Operaon & Electric Back Tilt
Jets & Lights
Water Fill Valve, Drain & Discharge Pump
Side Trays
Relaxor
Secon 4: Care & Maintenance
Ongoing Maintenance
Tub Cleaning Guide
Troubleshoong
Warranty Informaon
Electrical Specicaons
ETL Mark
FAQs
Contact Us
2-3
4
5
6
7
8
9
10
11
12
13
14
15
15
16
back cover
Table of Contents

READ AND SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFETY INSTRUCTIONS - FOR COMMERCIAL USE ONLY
Read all instructions before using this product.
Safety Symbols
Familiarize yourself with the following
Safety & Warning symbols. They are
designed to prevent damage and injury to
you, your clients, and your new Earthlite
product.
IMPORTANT: The important safety
instructions and warnings in this manual
cannot cover all possible problems and
conditions that can occur. Use common
sense and caution when installing,
operating, or maintaining this appliance.
Indicates an imminently hazardous
situation which could result in serious
or fatal injury.
Indicates a potentially hazardous
situation which could result in serious
injury.
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
SECTION 1: SAFETY INFORMATION
RISK OF ACCIDENTAL INJURY OR DROWNING. DO NOT USE
DRUGS OR ALCOHOL BEFORE OR DURING USE. CHILDREN
OR HANDICAPPED PERSONS SHOULD NOT USE WITHOUT
SUPERVISION.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the body temperature of 98.6°F or 37°C. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage bathtub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconciousness resulting in the danger of drowning. WARNING - The use of alcohol, drugs, or
medication can greatly increase the risk of fatal hyperthermia.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its
intended purpose: a manicure chair and ll and drain indoor commercial appliance for foot and ankle hydro
massage. DO NOT use attachments not recommended by manufacturer.
WARNING - MOVABLE PARTS, RISK OF INJURY:
• Keep children away from adjustable seat armrests, tilt back, and seat slide, and footrest.
WARNING - To reduce the risk of burns, re, electric shock, or injury to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled
persons. DO NOT leave children alone or allow them to operate the controls. Keep controls out of
reach of children. DO NOT allow children to crawl behind the chair.
• Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the furnishing to a service center for examination
and repair.
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, etc.
• Never drop or insert any object into any opening.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. WATER
TEMPERATURE IN EXCESS OF 38°C or 100.4°F CAN BE INJURIOUS TO YOUR HEALTH.
CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

READ AND SAVE THESE INSTRUCTIONS 3
SECTION 1: SAFETY INFORMATION
• DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
• DO NOT drop or insert anything into jet opening.
• DO NOT operate without the complete jet assembly installed or without water lled 1 inch above jets.
• DO NOT overll the basin.
• DO NOT stand on or in the basin, or on the foot rest.
• DO NOT leave this appliance unattended when in operation.
• DO NOT use outdoors.
• Keep the electrical cord away from heated surfaces.
• Connect this appliance only to a properly grounded outlet.
• To avoid injury, exercise care when entering or exiting the chair and foot bath.
• Use caution when making positioning adjustments to your chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
• It is important that you clean and disinfect the jets and basin after every use.
• Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
• You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are in-
amed, have an open wound, or if you have questions about whether you should be using hydro mas-
sage equipment.
• A qualied plumber and electrician are strongly recommended to install your foot bath.
• Make certain that the cord and plug are maintained in good condition and are not allowed to become
damaged while in use. Avoid positioning the cord in the trafc lane and it is always kept out of the way.
Take this furnishing out of service immediately if the cord or plug becomes damaged in any way.
• Do not attempt to repair. All repairs must be performed by an authorized service representative.
• Chair and tub are to remain right side up. At no time should chair or tub be turned on it’s side or upside
down.
1. RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault
circuit-interrupter.
2. Grounding is required. The unit should be installed by a qualied service
representative and grounded.
This product must be grounded. If it should malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Improper connection of the equipment-grounding connector can result in a risk of electric shock. Check
with a qualied electrician or serviceman if you are in doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product - if it will not t the outlet, have a proper outlet installed by
a qualied electrician.
INSTALLATION INSTRUCTIONS / GROUNDING INSTRUCTIONS
Reset
Button
GFCI Outlet
Grounding Pin
Test
Button
See Installation Manual for full
installation instructions

SECTION 2: PRODUCT OVERVIEW
4
Pillow
Shroud
Side Tray
Receivers
Sprayer/Fill
Water Fill
Valve
Control Panel
*Chair shown with oponal nishes
Footrest
Light
Tub Basin
Drain Handle
Armrest Door
Backrest Cushion
Back Tilt Control

*Measurements may vary due to natural material variaons.
5
Feature Standard Oponal
Pipeless Jet X
Reexology Fiberglass Tub X
Fully Motorized Seat and
Footrest X
Motorized Retractable
Armrest Doors X
Embedded Control Panel X
Power Drain/Discharge
Pump X
Relaxor® Heat & Massage X
Side Trays X
ADA Compliant X
Avonite Standard Opons Upgraded Opons
Upholstery Naturso™ Promessa® or
Ultraleather®
Included Features
Product Specications
Overall Width 32.5” (78.7 cm)
Shroud Width 22” (55.8 cm)
Shroud Height 15” (38.1 cm)
Length (armrest doors open) 73” (185.4 cm)
Length (armrest doors closed) 57” (144.8 cm)
Armrest Door Height 29.25” (74.3 cm)
Seat Height 21” (53.3 cm)/19” (48.3 cm) with ADA cushion
Control Panel
SECTION 2: PRODUCT OVERVIEW
Footrest

SECTION 3: OPERATING INSTRUCTIONS
Control Panel Operation
Slides seat fully
forward & opens
armrest doors
Your Contour control panel is connected and ready for use. See below for descripons of
each buon funconality. For the top row of buons, push and hold the buon unl the
chair movement stops - this means you have reached the memory posion. For the lower
set of buons, push and hold unl the desired posion is reached.
Always use extreme cauon when making any posion adjustments to your
chair. Ensure all body parts and objects are clear from all moving parts.
6
Closes armrest
doors
Seat memory
position 1*
(appx 2” back from
“open” position)
Seat memory
position 2*
(appx 4” back from
“open” position)
Raise
Footrest
Lower
Footrest
Slide Seat
Backward*
Slide Seat
Forward
Electric Back Tilt
The electric back lt buons are conveniently located on the inside of the le armrest door,
where clients can easily make lt adjustments themselves. See below for descripons of buon
funconality.
*NOTE: If the “Slide Seat Backward”, “Memory posion 1”, or “Memory posion 2” buons
aren’t working, ensure the armrest doors ARE FULLY CLOSED. These buons will not acvate if the
armrest doors are at all open. Posions are preset at factory and cannot be changed.
Decrease Seat
Back Tilt
Increase Seat Back Tilt
Increase Seat
Back Tilt
Reset Instrucons: If your chair requires reset, hold “Memory posion 2” buon for
approximately 1 second, this will place the chair in posion 2. Chair is now reset.

SECTION 3: OPERATING INSTRUCTIONS
7
Chromasoothe Light
Pressing the light bu on once will turn the light to the default Bright White color. Press the
switch again to cycle to the next color mode, in the following order:
1. Bright White
2. Aqua Blue
3. Soothing Blue
4. Ocean Blue
5. Majes c Gold
6. Shamrock Green
7. Fiery Red
8. Chameleon Mode
9. Party Mode
To reset, turn lights o for 5 seconds and turn back on. Lights will ash 4 mes and return to
Bright White.
Jets On/Off Button Chromasoothe Light Button
Jet System
The pipeless “magne c” system is standard in your pedicure unit. A er the basin is lled to
the proper level, turn jet on by pressing the chrome bu on next to the watever valve marked
“JET”. To turn o , press “JET” bu on a second me.
NOTE: Liners can be used on a “magne c” system. The liner has to sit between the motor
housing and the wet end assembly.
The jet assembly must be correctly assembled or it may be damaged. This
will NOT be covered by any Con nuum warranty. Never turn the jet on
without adequate water in the basin. There must be at least one (1) inch of
water above the motor housing.
Correctly
placed
impeller
Jet
Cover
Jet housing

SECTION 3: OPERATING INSTRUCTIONS
8
Discharge Pump (Optional)
Drain Knob
Turn the drain knob clockwise to close the drain when lling the tub. Turn the knob
counterclockwise to open the drain and empty the tub.
Water Fill Valve
There is no automa c shuto with the water ll valve. You MUST turn the
valve OFF a er the tub is lled to prevent over ow and/or ooding. Do not
walk away from the tub when it is lling with water.
Down-OffUp-FillLeft-Hot Right-Cold
The water ll valve is OFF when poin ng DOWN. Water dispenses when you pull the valve UP.
Hot water is dispensed when the valve is turned to the RIGHT. Cold water is dispensed when
the valve is turned to the LEFT.
Discharge pump bu on is located on the control panel. Before pressing the bu on, open
the drain with the drain knob and let the water start draining towards the pump. Wait
approximately 5-10 seconds for the pump to register, then push the discharge pump bu on.
Drain Knob
- Turn right to close
- Turn left to open
Discharge Pump
Button