Multi V 5 Outdoor Units
1. Specifications
HP 8 10
Model Name
Combination Unit ARUM080LTE5 ARUM100LTE5
Independent Unit
ARUM080LTE5 ARUM100LTE5
Capacity
Cooling kW 22.4 28.0
Btu/h 76,400 95,500
Heating kW 25.2 31.5
Btu/h 86,000 107,500
Input Cooling kW 4.28 5.22
Heating kW 4.78 5.92
EER 5.23 5.36
COP 5.27 5.32
Exterior Color Morning Gray / Dawn Gray Morning Gray / Dawn Gray
RAL (Classic) RAL 7030 / RAL 7037 RAL 7030 / RAL 7037
Heat Exchanger Wide Louver Plus Wide Louver Plus
Compressor
Type Hermetically Sealed Scroll Hermetically Sealed Scroll
Piston Displacement cm3/rev 43.8 62.1
Number of Revolution rev/min 3,600 3,600
Motor Output x Number W x No. 4,200 × 1 5,300 × 1
Starting Method Inverter Inverter
Oil Type FW68D(PVE) FW68D(PVE)
Fan
Type Propeller fan Propeller fan
Motor Output x Number W 1,200 × 1 1,200 × 1
Air Flow Rate(High) m3/min 240 × 1 240 × 1
ft3/min 8,476 × 1 8,476 × 1
External Static Pressure (Max, Pa) 80 80
Drive DC INVERTER DC INVERTER
Discharge Side / Top TOP TOP
Pipe
Connections
#1
Liquid mm(inch) 9.52(3/8) 9.52(3/8)
Low Pressure Gas mm(inch) 19.05(3/4) 22.2(7/8)
High Pressure Gas mm(inch) 15.88(5/8) 19.05(3/4)
Pipe
Connections
#2
Liquid mm(inch) 9.52(3/8) 9.52(3/8)
Gas mm(inch) 19.05(3/4) 22.2(7/8)
Dimensions(W x H x D) mm (930 × 1,690 × 760) × 1 (930 × 1,690 × 760) × 1
inch (36-5/8 × 66-17/32 × 29-29/32) × 1 (36-5/8 × 66-17/32 × 29-29/32) × 1
Net Weight kg 198 × 1 215 × 1
lbs 437 × 1 474 × 1
Sound
Pressure Level
Cooling dB(A) 58.0 58.0
Heating dB(A) 59.0 59.0
Sound Power
Level
Cooling dB(A) 77.0 78.0
Heating dB(A) 78.0 79.0
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the semi-anechoic rooms by ISO 9614 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
4. Sound values of combination model are calculated values based on sound results of independent models.
Sound values can be increased owing to ambient or installation conditions during operation.
Sound values of system [dB(A)] = 10*log [10^(A1/10)+ ... +10^(An/10)] , A1~An means sound values of independent models.
5. Performances are in accordance with ISO 15042.
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
6. *** : The number in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160~200%).
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)
8. #1 : Heat Recovery system, #2 : Heat Pump system