Lutron Electronics DM-9983G Bedienungsanleitung

Green power, hybrid power
SMART
MULTIMETE
R
Model : DM-9983G
Y
our purchase of this
SMART MULTIMETER
marks a step forward for
you into the field o
f
precision measurement.
A
lthough this
MULTIMETER is a complex
and delicate instrument, its
durable structure will allow
many years of use i
f
proper operating
techniques are developed.
Please read the following
instructions carefully and
always keep this manual
within easy reach.
OPERATION MANUAL

Caution Symbol
Caution :
* Risk of electric shock !
Caution :
* Do not apply the overload
voltage, current to the input
terminal !
* Remove test leads before open
the battery cover !
* Cleaning - Only use the dry
cloth to clean the plastic case !
Environment Conditions
*
Installation Categories III 600V.
*
Pollution Degree 2.
*
Altitude up to 2000 meters.
*
Indoor use.
*
Relative humidity 80% max.
Equipment protected throughout
by double insulation or reinforced
insulation.

TABLE OF CONTENTS
1. FEATURES................................................................ 1
2. SPECIFICATIONS......................................................
.
2
3. FRONT PANEL DESCRIPTION.....................................6
3-1 Display................................................................6
3-2 Power ON button................................................. 6
3-3 Hold button......................................................... 6
3-4 Select button....................................................... 6
3-5 Hz button............................................................ 6
3-6 Range button .....................................................
.
6
3-7 Function switch...................................................
.
6
3-8 V/Ωterminal ......................................................6
3-9 COM terminal .....................................................
.
6
3-10 mA terminal.......................................................6
3-11 10 A terminal.....................................................6
3-12 Handle of power generator................................. 6
3-13 Stand................................................................ 6
3-14 Battery compartment/cover................................ 6
3-15 Power type switch ( G/B switch )........................
.
6
4. POWER TYPE SELECTION........................................ 6
MEASURING PROCEDURE..........................................
.
8
5-1 Precautions & preparations for measurement.......
.
8
5-2 Power management............................................. 8
5-3 Symbols & Units of Display ..................................9
5-4 Voltage ( ACV/DCV ) measurement....................... 10
5-5 Resistance measurement.....................................
.
10
5-6 Continuity, Diode measurement............................ 10
5-7 Capacitance measurement...................................
.
12
5-8 Current mA ( AC/DC ) measurement..................... 13
5-9 Current 10A ( AC/DC ) measurement....................
.
13
5-10 Smart/Auto function selection............................. 14
5-11 Range selection.................................................
.
14
5-12 Hz measurement...............................................
.
15
5-13 Data Hold.......................................................... 15
6. MAINTENANCE.......................................................... 15
7. OPTIONAL ACCESSORIES & ADAPTERS .....................
.
17
8. PATENT.................................................................... 17
9. THE ADDRESS OF AFTER SERVICE CENTER................18

1. FEATURES
* Green power, battery is no need, power supply from the
handy generator, operate the generator 10 to 20 seconds
will offer 10 minutes energy typically.
* Hybrid power, meter also can supply by the battery.
* Meet CAT III-600 V.
* 6000 counts A/D, high resolution.
* ACV, ACA, DCV, DCA, ohms, continuity, Hz,
Capacitance, Diode, Data hold.
* Smart function, Auto range or manual range with hold.
* Smart operation, Build in 4 intelligent function :
" V ", " Ω", " mA ". " 10A ".
* " V " function can select ACV, DCV automatically with
auto range.
*"Ω" function can select the Resistance , Diode,
Continuity beeper, Capacitance automatically with
auto range.
* " 10A " " mA " function can measure ACA, DCA with
auto range.
* Data hold ( auto range ).
* Auto shut off is available to save battery life.
* Both 10 A, mA current range are build fuses for safety
consideration.
* 10 M ohm impedance for voltage circuit.
* Built-in overload protection for most ranges.
* LSI circuit provides high reliability and durability.
*Patent.
* Uses durable, long-lasting components, enclosed in
strong, light weight ABS-plastic housing.
* Full line optional adapters : Clamp adapter,
Tachometer adapter, Pressure adapter, Humidity
Adapter, Sound level adapter, Anemometer adapter,
Light adapter, EMF adapter.
1

2. SPECIFICATIONS
2-1 General Specifications
Green power * Green power, battery is no need,
and power supply from the handy
Hybrid power generator, operate 10 to 20
seconds the generator will offer
10 minutes energy typically.
* Hybrid power, meter also can
supply by the battery power.
Display 46 mm x 45 mm large LCD display.
Measurement ACV, ACA, DCV, DCA, ohms,
continuity beeper, Hz, Capacitance,
Diode, Data hold.
A/D counts no. 6000 counts.
Range selection Smart function, auto range or
manual range selecting.
Smart function " V " function can select ACV, DCV
automatically with auto range.
" Ω" function can select the
Resistance, Diode, Continuity
beeper, Capacitance automatically
with auto range.
" 10A " " mA " function can measure
ACA, DCA with auto range.
Data hold To freeze the display reading on the
LCD display.
* Available for auto range only.
Power On/Off If meter is not operated within 3
management minutes will auto power switch off.
Polarity Automatic Switching, " - " indicates
negative polarity.
Sampling time Approx. 0.5 to 1 second.
Operating 0 to 50 (32 to 122 ).℃℉
Temperature
2

Operating Less than 80% RH.
humidity
Power Green power :
Supply Power from the handy generator,
battery is no need.
Battery power :
DC 3V battery ( CR-2032 ) x 2 PCs.
Power consumption DC 3 mA.
Weight 340 g/0.75 LB.
Dimension 152 x 78 x 45 mm
( 6.0 x 3.1 x 1.8 inch )
Accessories Red and Black Test Leads........ 1 Set
Included Instruction Manual..................
.
1 PC
Optional Full line adapters :
accessories * ACA/DCA current adapter :
CA-502, CA-203, CA-501
* ACA current adapter : CA-201
* Pressure adapter : PS-403
* Light adapter : LX-02
* EMF adapter : EMF-824
* Sound level adapter : SL-406
* High voltage probe : HV-40
2-2 Electrical specifications (23±5 )℃
DC/AC Voltage
* auto range
Range 6 V /60 V/600 V
Resolution 0.001 V /0.01 V/0.1 V
Accuracy DCV : ± ( 1 % + 2d )
ACV : ± ( 1.2 % + 5d )
Input impedance 10 M ohm.
Over load protection AC/DC 600 V.
Remark
* The input impedance is 10 Mega ohm.
* ACV specification be tested on sine
wave 50/60 Hz.
* For smart function ,the ACV start
measurement voltage is larger than
400 mV ± 100 mV.
3

DC/AC Current
* auto range
Range mA range 600 mA/60 mA
10 A range 10A
Resolution mA range 0.1 mA/0.01 mA
10 A range 0.01 A
Accuracy mA range ± ( 1.2% + 2d )
10 A range ± ( 1.5% + 2d )
Over load mA range 630 mA fuse
protection 10 A range 10 A fuse
Remark
* ACA specification be tested on
sine wave 50/60 Hz.
* For smart function ,the ACA start
measurement is
10 A range : 1.50 A.
mA range : 1.50 mA.
OHMS
* auto range
Range 600/6 K/60 K/600 K/6 M ohm
Resolution 0.1/1/10/100/1 K ohm
Accuracy ± ( 1% + 3d )
Over load protection ± 350 DCV, 350 ACV
Capacitance
* auto range
Range 6 nF/60 nF/600 nF/6 uF/60 uF
Resolution 0.001 nF/0.01 nF/0.1 nF/0.001 uF/
0.01 uF
Accuracy ± ( 3% + 5d )
Remark
Discharge capacitor before testing.
Frequency
Range 40 Hz to 1 KHz.
Resolution 1 Hz.
Accuracy ± ( 0.3% + 2d )
Input impedance 10 M ohm.
Over load protection AC/DC 600 V.
4

Diode
Short/non conductance, good/defect test.
Continuity
If measuring resistance is less than 10 ohm, the beeper
will sound .
5

3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display
3-2 Power On button.
3-3 Hold button
3-4 Select button
3-5 Hz button
3-6 Range button
3-7 Function switch
3-8 V/Ωterminal
3-9 COM terminal
3-10 mA terminal
3-11 10 A terminal
3-12 Handle of power generator
3-13 Stand
3-14 Battery compartment/cover
3-15 Power type switch ( G/B switch )
6

4. POWER TYPE SELECTION
4-1 Power supply from the generato
r
( Green power supply )
1)Select the " Power type switch " ( 3-15, Fig. 1 ) to
the " G position " ( Green power position ).
There is a " Power generator's handle " ( 3-12, Fig. 1 )
on the top of the housing case.
LCD display
Power generator's handle
2)Lift and extend the " Power generator's handle "
and rotate the handle in clockwise direction will
generate the power energy into the meter, refer
to Fig. a, b, c.
Fig. a
Fig. c
Fig. b
c. Wind-up the generator 10 to 20 seconds will offer 10
minutes energy typically. If wind-up the generator
more time, the meter will be saved more energy and
let the meter be operated for a long period.
7
Inhaltsverzeichnis
Andere Lutron Electronics Multimeter Handbücher

Lutron Electronics
Lutron Electronics AM-4205A Bedienungsanleitung

Lutron Electronics
Lutron Electronics LCR-9184 Bedienungsanleitung

Lutron Electronics
Lutron Electronics DM-9962SD Bedienungsanleitung

Lutron Electronics
Lutron Electronics DM-9961 Bedienungsanleitung

Lutron Electronics
Lutron Electronics DM-9030 Bedienungsanleitung
Beliebte Multimeter Handbücher anderer Marken

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Bedienungsanleitung

PeakTech
PeakTech 4000 Gebrauchs- und Pflegehandbuch

YOKOGAWA
YOKOGAWA 90050B Bedienungsanleitung

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Bedienungsanleitung

Fluke
Fluke 8846A Bedienungs- und Wartungshandbuch

Tempo Communications
Tempo Communications MM200 Bedienungsanleitung