LVI Touch E3 Bedienungsanleitung

1|
INSTALLATION AND OPERATING MANUAL
The Touch E3 can control certain LVI devices, please see each device´s
instruction manual.
MANUEL D'INSTALLATION ET D'UTILISATION
Le Touch E3 peut contrôler certains appareils LVI, consultez le manuel
d’utilisation de chaque appareil pour plus d’informations.
GB
FR
TOUCH E3


P16MI417 - A02 - 01/16 3|
FOR THE INSTALLER
INSTALLATION OF THE TOUCH SCREEN
01. Main characteristics
• Touch screen (4 inches)
• Interface via internet.WiFi 2.4 GHz (not 5.0 GHz)
• Wall mountable with power supply 85-265V (50-60)Hz
• Can be placed on the table with supplied bracket,and mini USB power supply (5V).
• Battery operation (only for settings)
• RF Communication with other devices
• Multiple heating device control.
• SD Card update
• Intuitive menus for device management
! Charge the Touch E3 for at least one hour before pairing the devices
already mounted.
02. Available devices for connecting to Touch E3 (For example: Yali Digital,
Parada and Ramo)
• Up to 50 rooms (zones) with one master radiator in each room.
• Up to 50 slave radiators to be distributed among the masters.
Examples: a) 50 zones with 1 master and 1 slave in each, total 100 radiators
b) 1 zone with 1 master and 50 slaves, total 51 radiators.
It is recommended to limit the number of slaves to 10 in one zone.
FOR
THE INSTALLER UK

| 4 P16MI417 - A02 - 01/16
FOR
THE INSTALLER
UK
03. Wall mounting
• Connect the power supply as described below. The electrical installation
must comply with local or national regulations. The product should be
connectedbyasuitableandqualiedelectrician.
TEMP. PRECISION: 0.1°C
ENVIRONMENTAL
CONDITIONS:
- Operating temperature
- Shipping and storage temp.
-0°C to +40°C
-30°C to +50°C
SETTING TEMPERATURE
RANGE:
- Comfort mode
- Reduced mode
- Frost protection mode
+5.5°C to +30°C, must be higher than the reduced mode temperature.
+5°C to +19°C, must be lower than Comfort mode temperature.
+0.5°C to +10°C
ELECTRICAL INSULATION: Class II
ELECTRICAL PROTECTION: IP 30
RADIO FREQUENCY:
- Range outside
- Range indoor (typical)
868 MHz, <10mW
200 m
Around 15 m
WIFI FREQUENCY:
2.4 GHz (not 5.0 GHz). Touch E3 supports the following standards:
- 802.11b at 2.4Ghz- 802.11g mixed 5GHz / 2.4GHz
Note that if your router is set to this standard ‘802.11g mixed
5ghz / 2.4GHz’ then it is mandatory to select the type of Key
to ‘WPA/WP2 mixed’ in order to connect in 2.4GHz with the
Microchip 2.4GHz WiFi module.
SOFTWARE VERSION Can be found at the bottom of the Main menu: xx.xx
CanbefoundatthebottomrightoftheWimenu:xxxxxx.xx
POWER SUPPLY 85-265V 50-60 Hz
CE DIRECTIVES:
Your product has been
designed in conformity with
the European Directives.
LV Directive 2006/95/EC
EMC Directive 2004/108/EC
R&TTE Directive 1999/5/EC
RoHS 2011/65/EU
POWER SUPPLY 85-265V, 50/60 HZ
NOT TO BE USED!

P16MI417 - A02 - 01/16 5|
• Screw the power supply on to the wall.
NOTE: The tab must be located at the top.
• Put the switch into the ON position by using a small pin
• Connect the mini USB cable and charger to the Touch E3.
• Mount the Touch E3 onto the bracket by sliding it down until it stops.
• Put the switch into the ON position by using a small pin
• The Touch E3 is now ready for use.
• Mount the Touch E3 on the power supply and slide it down until it stops.
• The Touch E3 is now ready for use.
04. Table installation
60 MM
ON / OFF
ON / OFF
CABLE
FOR
THE INSTALLER UK

| 6 P16MI417 - A02 - 01/16
05. General pictograms
SETTING LANGUAGE, TIME AND DATE
01. Press “Main menu” button A
02. Press “Set language” button D
•Theagofthecurrentlanguageisdisplayed.
03. Press “User settings” button F
• Set the current time and date
to return to the “Start screen”
to return to the previous screen
the buttons with a red dot require a long press
FOR
THE INSTALLER
UK
MAIN MENU
BUTTON
START SCREEN
SET LANGUAGE
USER SETTINGS PARAMETER SETTINGS
AB
MAIN MENU
C
F
D
G
E
H I

P16MI417 - A02 - 01/16 7|
CREATE HOUSE
01. Press “Main menu” button A
02. Press the “Parameter settings” button I (long press)
03. Press the “House creation” button
• Create all the rooms (or zones)
a Current room name
bTo change the current room name
c To add a room
dTo delete the current room
e Room selection
PAIRING RADIATORS
01. Press “Main menu” button A
02. Press the “Parameter setting” button I (long press)
• >> Select radio pairing
• Choose device, press “Heating”.
• Select room
FOR
THE INSTALLER UK
a
b
c
e e
d
RADIO PAIRING
ROOM MENU

| 8 P16MI417 - A02 - 01/16
• Start the pairing by pressing“radio pairing” button f
• Follow the instruction on the screen (depending on the type of device) .
• Repeat the steps for all devices, starting at >> Select radio pairing
•Press“Greencheck”buttontoconrm
• Device (Radiator or Remote Control) to measure the temperature
must be paired first in this zone!
•Press“Greencheck”buttontoconrm
03. Put the device (radiator or remote control) in pairing mode.
•Seedeviceleaetormanual
EXAMPLE: YALI DIGITAL /P/R
Press and hold the “OK” key for 5 seconds
rFi: Wireless Radio initialization (pairing)
Press “OK”to enter this initialization sequence.
Select with“+”or “-”the radio communication type and validate by pressing “OK”:
• rF.un: unidirectional communication, the digital thermostat only receives
orders from an LVI RF central programmer.
•rF.bi: bidirectional communication with an LVI Touch E3. The digital
thermostat communicates state and power consumptions to the LVI Touch E3.
Then the backlight will switch off and the digits will cycle showing that
the digital thermostat is waiting for a radio link signal from a Central
programmer or LVI Touch E3 to be received (press “”to cancel radio
initialization).When the radio link signal is received, pairing is saved,
then it will return to Auto mode.
FOR
THE INSTALLER
UK
RADIO PAIRING
BUTTON
f

P16MI417 - A02 - 01/16 9|
FOR
THE INSTALLER UK
When you have completed the pairing of all devices and each device is
installed in its final location, check that communication is established
between each device and the Central Unit.
Before checking, install the Central Unit in its final location. Checking
is undertaken by adjusting the heating mode or the set point on the
Central Unit and confirming that that the adjustment instruction has
been received by the Thermostat and the Receiver

| 10 P16MI417 - A02 - 01/16
04. Installation types (Type 1)
FOR
THE INSTALLER
UK
TOUCH E3
MASTER
SLAVE 1
SLAVE 2
Andere Handbücher für Touch E3
2
Inhaltsverzeichnis
Sprachen: