Magicfx FLAMEBLAZER Betriebsanleitung

FLAME FX PART01875
rev 01-01
USER AND INSTALLATION MANUAL
ENGLISH
®
FLAMEBLAZER.

2 MAGICFX FLAMEBLAZER®—User and Installation Manual
DISCLAIMER
WARNING Read this manual carefully before installing and/or using this
product. Failure to read the manual and to follow the printed
instructions may lead to personal injury and/or damage to the
product.
© 2020 MAGICFX®
All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by
means of printing, photocopying or by any other means, without the prior written
approval of MAGIC FX.
MAGIC FX reserves the right to modify specications stated in this manual.
TRADEMARKS
Any brand names mentioned in this manual are registered trademarks of their
respective owners.
LIABILITY
MAGIC FX accepts no liability for claims from third parties arising from unauthorised
use, use other than that stated in this manual, and use other than in accordance with
the General Conditions registered at the Chamber of Commerce.
We further refer to the General Conditions. These are available on request, free of
charge.
Although considerable care has been taken to ensure a correct and comprehensive
description of all relevant components, the manual may nonetheless contain errors
and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if
you would inform us. This helps us to further improve our documentation.

MAGICFX FLAMEBLAZER®—User and Installation Manual 3
TABLE OF CONTENTS
Disclaimer 2
Trademarks 2
Liability 2
Foreword 4
Language 4
Revision table 4
1 Meet the FLAMEBLAZER®! 5
1.1 Main parts 6
1.2 MAGICFX FLAMEBLAZER®FUEL 6
1.3 Technical data 7
1.6 DMX control 9
1.7 Display panel 10
2 FLAME safely! 14
2.1 General safety rules 14
2.2 Rigging 14
2.3 Noise Levels 14
2.5 Safety warnings 15
3.4 Mount on a truss 26
3.5 Connecting the machine 29
3.6 Setup multiple machines in a sequence with DMX 31
3.7 Let’s FLAME! 32
5 Maintenance 34
6 Correct disposal 37
7 EC Declaration of Conformity 39

4 MAGICFX FLAMEBLAZER®—User and Installation Manual
FOREWORD
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment.
Deviation from the described intended use can result in a hazardous situation and/or
property damage.
This manual includes notes and warnings on safe operation of the equipment. These
notes and warnings are accompanied by the following icons. Read them attentively!
DANGER Indicates a hazardous situation that, if not avoided, will result in
death or serious injury. This signal word is to be limited to the most
extreme situations.
WARNING Indicates a hazardous situation that, if not avoided, could result
in death or serious injury.
CAUTION Indicates a hazardous situation that, if not avoided, could result
in minor or moderate injury.
NOTICE Indicates information considered important, but not hazard-
related (e.g. messages relating to property damage).
LANGUAGE
This document contains the original instructions in English. In case you require other
languages please contact MAGIC FX.
REVISION TABLE
Doc nr Revision Date Description Author Approved
PART01875 01-00 03-6-2020 Initial release MB, ES RD
PART01875 01-01 27-10-2020 Updated graphics PW LL

MAGICFX FLAMEBLAZER®—User and Installation Manual 5
1 MEET THE FLAMEBLAZER®!
The MAGICFX FLAMEBLAZER® is a special eects machine for controlled emission of
ame jets into the air in a xed direction.
The machine uses specic ammable fuels that are projected from a single outlet
across spark ignition probes to produce the ame jet. An integrated electric pump
draws the fuel from the 5 L can and generates the ring pressure.
There are three nozzles available with the MAGICFX FLAMEBLAZER®which are
interchangeable, allowing the user to choose a small, medium or large ame. Based
on zero wind the sizes are as follows:
• L nozzle, up to 10 m (included);
• S nozzle, up to 6 m (accesory);
• M nozzle, up to 8 m (accesory).
A specic nozzle exchange tool is available to change between the S, M and L
nozzles (SFX 1404)
The FLAMEBLAZER®has a dedicated safety circuit so must be used in conjunction with
a MAGICFX® FX-ARM CONTROLLER (MFX 3220).
The MAGICFX FLAMEBLAZER® is tted for operation:
• With DMX and RDM;
• With an external Low Voltage Pyro input (typical 12-40 Vdc);
• In sequence with multiple machines.

6 MAGICFX FLAMEBLAZER®—User and Installation Manual
1.1 MAIN PARTS
Main parts
1.2 MAGICFX FLAMEBLAZER®FUEL
The MAGICFX FLAMEBLAZER® uses two types of fuel to create the eect. The fuel is
loaded into an ADR Can 5 L located in the machine.
NOTICE Only use these types of fuel: Isopropanol, ISOPAR G, H & L. The use
of other fuels or water may degrade the performance of the
machine or cause internal damage.
CAUTION Fuels are highly ammable and must be handled with caution
and in accordance with local health and safety regulations.
Always follow the safety instructions from the fuel packaging
when handling and working with the fuel.
BURN CHAMBER
FLUID ENCLOSURE
PYRO INPUT
FX-ARM CONTROLLER
INPUT & OUTPUT
SAFETY EYE
DMX INPUT & OUTPUT
(5-POLE)
SCREEN & BUTTONS FX LED INDICATION
POWER INPUT & OUTPUT

MAGICFX FLAMEBLAZER®—User and Installation Manual 7
1.3 TECHNICAL DATA
Product Product Name MAGICFX FLAMEBLAZER®
Product Code MFX1401
Product Type FLAME FX
Main
Dimensions
Length 410 mm 16.4 in
Width 300 mm 11.8 in
Height 281 mm 11 in
Weight Empty Weight 18.7 kg 41 lbs
Package Length 540 mm 21.3 in
Width 400 mm 15.7 in
Height 420 mm 16.5 in
Packaged Weight 20.7 kg 45.6 lbs
Environment Minimum Temperature -10 ºC 14 ºF
Maximum Temperature) 50 ºC 122 ºF
Humidity (Relative) 20 % to 90 % (non condensing)
Electrical Voltage Input 220-250 Vac
Voltage Frequency 50-60 Hz
Power Consumption 370 W
Power Connector Neutrik®powerCON TRUE1 (in&out)
Controlling Control Options DMX / Pyro
Control Protocols DMX512-A (ANSI E1.11)
RDM (ANSI E1.20)
≈ 9-40 Vdc
Control Connectors Neutrik®5-pole male/ female XLR
4 mm banana socket
Arm
Controlling
Control Connectors Neutrik®etherCON / RJ45
Congure Options On Device & RDM
Usage Consumable(s) Isopropanol, ISOPAR G, H & L
Consumable Consumption S nozzle: ≈ 12 ml/s
M nozzle: ≈ 30 ml/s
L nozzle: ≈ 50 ml/s
Technical data

®—User and Installation Manual
1.4 PRODUCT IDENTIFICATION
Type plate
1.5 ACCESSORIES
Code Product Included
SFX1401 MAGICFX FLAMEBLAZER® Nozzle S
SFX1402 MAGICFX FLAMEBLAZER® Nozzle M
SFX1403 MAGICFX FLAMEBLAZER® Nozzle L 1x
SFX1404 MAGICFX FLAMEBLAZER® Nozzle exchange tool
MFX0313 Schuko to Neutrik®powerCON TRUE1 cable - 1.5 m
MFX0305 MAGICFX®BASEPLATE II
MFX3106 Doughty Half Coupler (100 kg) M10
SPR00119 Safety Steel
SPR01885 Empty ADR Can 5 L (w/out Cap) 1x
SPR90106 MAGICFX FLAMEBLAZER® CUSTOM CAN CAP 5L 1x
MFX3220 MAGICFX®FX-ARM CONTROLLER
MFX3080 MAGICFX® Flame Fluid IPA 5L
MFX3086 MAGICFX® Flame Fluid Isopar L 5L
Accessories
Please contact MAGIC FX for additional possibilities.

MAGICFX FLAMEBLAZER®—User and Installation Manual 9
1.6 DMX CONTROL
The MAGICFX FLAMEBLAZER®is controlled with 1 enable address and 1 operational
address:
DMX address Address range Control
Enable address 1 - 512 Device enable/disable
Start address 1 - 512 Eect trigger
DMX addresses
The enable address cannot be the same as the operational address. Operating of
these addresses results in the following:
DMX address DMX Value (decimal) Result
Enable address 0 99 Device disabled
100 154 Device enabled
155 255 Device disabled
Start address
(Eect trigger)
0 199 No output
200 255 Output eect
Operation of the DMX addresses
NOTICE The maximum continuous duration of the eect is 5 seconds. Aer
this period the eect will stop automatically. To start the eect
again you must disable and re-enable the Eect trigger.
NOTICE Always plug in a DMX Terminator into the DMX output of the nal
unit in the control sequence. Using a DMX Terminator improves
signal reliability.

10 MAGICFX FLAMEBLAZER®—User and Installation Manual
1.7 DISPLAY PANEL
MAIN MENU
DMX/RDM SETTINGS
BACK PREV NEXT
SELECT
SIGNAL INFO
Display panel
The display panel is located on the backside of the MAGICFX FLAMEBLAZER®. Check
the following menu structure for all options in the menu. Use the buttons for
navigation and selection. The signal LED blinks red when DMX signal is active. The
info LED continuously lights red when an error is present.
Andere Handbücher für FLAMEBLAZER
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Magicfx Scheinwerfer Handbücher
Beliebte Scheinwerfer Handbücher anderer Marken

VIZULO
VIZULO Micro Martin Benutzerhandbuch

EuroLite
EuroLite LED IP FL-100 SMD Bedienungsanleitung

Cooper Wheelock
Cooper Wheelock XB12 Bedienungsanleitung

Allen + Roth
Allen + Roth 17624-000 Bedienungsanleitung

ADJ
ADJ 4 STAGE PAK Bedienungsanleitung

Cooper Lighting
Cooper Lighting EGL91SW233 Bedienungsanleitung