Magmaweld DFM 1000 Bedienungsanleitung

DFM 1000 - 1250 - 1500
(+90) 444 93 53
magmaweld.com
info@magmaweld.com (+90) 538 927 12 62
USER MANUAL

All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written
Magma Mekatronik may modify the information and the images without any prior notice.

TR
EN
WELDING FUME EXTRACTION SYSTEMS
3DFM 1000 - 1250 - 1500

4
www.magmaweld.comUSER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN CONTENTS
Contents
1
1.1
1.2
1.3
2
2.1
3
3.1
3.2
3.2.1
4
4.1
4.2
4.3
4.4
5
5.1
5.2
5.3
5.4
SAFETY PRECAUTIONS
TECHNICAL INFORMATION
General Information
Product Label
Technical Data
INSTALLATION
Implementation of the Unit
OPERATION
Command Panel
Filter Usage Information
Economical Life of the Filter
MAINTENANCE AND SERVICE
Maintenance and Annual Controls of the Filters
Changing the Filters
Destruction the Filters
Troubleshooting
ANNEX
Dimensions
Spare Parts List
Circuit Diagrams
Smoke Filtering Systems Maintenance Chart
5
7
8
8
9
10
10
10
11
11
11
12
14
15
17
19

5
www.magmaweld.com USER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN
Safety Precautions
Be Sure To Follow All Safety Rules In This Manual!
• Safety symbols found in the manual are used to identify potential hazards.
• When any one of the safety symbols are seen in this manual, it must be understood that there is
a risk of injury and the following instructions should be read carefully to avoid potential hazards.
• During operation of the welding fume extraction systems, keep third parties other than the
operators, especially children, away from the working area.
Explanation Of Safety
Information
• Read the user manual, the label on the machine and the safety instructions carefully.
• Make sure that the warning labels on the machine are in good condition. Replace missing and
damaged labels.
• Learn how to operate the machine, how to make the checks in a correct manner.
• Use your machine in suitable working environments.
• Improper changes made in your machine will negatively affect the safe operation and its
longevity.
your machine affect the safety of your machine negatively and shorten its lifetime.
Comprehending Safety
Precautions
SAFETY PRECAUTIONS
Make certain that the installation procedures comply with national electrical standards
persons.
• Installation procedure must comply with national electricity standards and other relevant
• Wear dry insulating gloves free of damage and body protection.
• If damage is detected on any of the cables of the machine, please contact the authorized persons
and disconnect the power supply cable from the electrical outlet.
• The unit is manufactured according to CE security standards. Although, the unit may cause
serious injuries loss of limbs.
• Turn off the machine, when not in use.
• Disconnect the power connections and/or plugs or turn off the machine before repairing the
unit.
• Be carreful while working with a long input power cord.
• Frequently inspect all the cables against damages. Repair or replace the damaged or
uninsulated cables immediately if damaged.
• Make sure that the electric line is properly grounded.
Electric Shocks
May Kill
this may cause serious injuries and loss of limbs.
disassemble the springs attached to the arms as they may cause injury.
overturn and this may cause serious injuries.
• Keep all the protectors such as covers, panels, doors, etc. of the machines and devices close and
locked.
objects.
Welding Wires Can
Cause Injuries
• Electrical equipment should not be repaired by unauthorized persons. Failure to do so may
result in serious injuries or death.
the services provided by unauthorized people regarding the smoke, dust, odor absorption and
Maintenance Done
On The Machines And
Apparatus May Cause
Injuries

6
www.magmaweld.comUSER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN
• Allow the machine to cool according to the operating cycle rates.
approval.
Overuse Can Cause
The Overheating
Of The Machine
the power supply to the machine can cause a hazardous situation.
• Machines should not start unexpectedly,
• The parameters of the machines should not be changed uncontrollably if such a change may lead
to a dangerous situation,
• Stop command of the machine should not be prevented,
• No moving parts of the machine or any parts held by the machine should fall or dislodge,
• Automatic or manual stopping of moving parts in any way is prevented.
• The protective devices must remain fully active or issue a stop command.
Power Supply Failure
• Do not expose the machine to rain, avoid splashing water or pressurized steam. be.
Protection
• Turn off the machine if it will wait a long time without working. This will also extend the life of
Safety Precautions
equipment may cause serious injuries for people or may damage the objects.
interconnections, lift and carry the small ones from their handles and the larges ones from their
carriage rings or by using appropriate lifting equipment, such as forklifts.
hoses and preventing the exit of the air absorbed.. In order to restrict the movement of the mobile
systems, close the locks of the front wheels.
• Ensure that operators can easily access the settings and connections on the machine.
• Observe the warning lights on the control panel and follow the instruction manual.
Falling Parts
May Cause Injuries

7
www.magmaweld.com USER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN
Figure 1 : DFM Front View
In case of improper use, dust and fume are not absorbed correctly. For this reason, lungs and
respiratory tract may be damaged!
Keep the user manual well!
TECHNICAL INFORMATION
1.1 General Information
extractors can be used with variable tray and cover options.
Technical Information

8
www.magmaweld.comUSER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN
1.3 Technical Data
TECHNICAL DATA
Mains Voltage
Depression Value Maximum
Protection
Filter Members
Atmospher
Mains Frequency
Nominal Current
ISO
Motor Output
Command Voltage
Air Suction Rate Maximum
Weight
Ambient
Noise Level
UNIT
(*) : insulation class of engine according to IEC 60085
Dimensions (UxGxY)
V
Hz
kW
m3/ h
A
V
kg
mm
%
dB
C
2000 Pa
IP X0
Maximum 72%
4
F
99
24 V/AC
3000
72
Pre Roughing Filter, Main Filter
DFM 1000 - 1250 - 1500
1.5
Mains Voltage and FrequencyU
Rated current drawn from theI
Power drawn from the mains
DFM 1000 DFM 1250
DFM 1500
1.2 Product Label
Technical Information

9
www.magmaweld.com USER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN
•
outlet and make sure that the entire unit is complete as described in the user manual.
•
•
illuminates, the suction motor is reversed and the suction will be too weak. In this case, change the place
displacement of the phases, the suction motor will rotate in the correct direction and strong suction will
start and the red warning light will go out. Your unit is ready to use.
•
•
immediately.
INSTALLATION
2.1 Implementation of the Unit
Installation

10
www.magmaweld.comUSER MANUAL | KULLANIM KILAVUZU
DFM 1000 - 1250 - 1500
EN
1 -
2 -
3 -
4 -
Figure 2 : DFM Model Panel Label
DFM
WELDING FUME
EXTRACTION SYSTEM
ENGINE
INDICATORS
WRONG
ROTATION
FILTER INDICATORS
MAIN FILTER
GOOD
MAIN FILTER
CHANGE
STOP
STARTSTART
STOP
3.2 Filter Usage Information
Recommended replacement intervals are as follows:
3.2.1 Economical Life of the Filter
Operation
OPERATION
3.1 Command Panel
Filter Member
Main Filter
Carbon Filter
Changing Period
100 hrs
1000 hrs
Contaminants can pose a threat for your health by penetrating into the air.
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Sprachen:
Andere Magmaweld Schweißzubehör Handbücher
Beliebte Schweißzubehör Handbücher anderer Marken

Lincoln Electric
Lincoln Electric LT-7 Tractor Bedienungsanleitung

Weco
Weco Trolley R Bedienungsanleitung

Cornwell Tools
Cornwell Tools MMWC1 Bedienungsanleitung

Dohle
Dohle ExOn2A Bedienungsanleitung

Nederman
Nederman Fume Eliminator FE 840/2500/P150 Bedienungsanleitung

3M
3M Speedglas 9100 Series Bedienungsanleitung

Miller Electric
Miller Electric OM-842 Bedienungsanleitung

Miller
Miller A-200 Series Bedienungsanleitung

Abicor Binzel
Abicor Binzel ABIMIG WT Series Bedienungsanleitung

optrel
optrel lifeflip autopilot Bedienungsanleitung

Miller
Miller MIGmatic M-25 Bedienungsanleitung

Tregaskiss
Tregaskiss TOUGH GUN TT3 Reamer Bedienungsanleitung