INSTALLATION
Preparing for Installation
♦Turn OFF all power to the vending machine.
♦To ensure that the EC6000 performance is not
affected, visually check the vending machine is
upright, both from the front and side.
♦Before mounting the EC6000 to the vending
machine, check the operating voltage of the vending
machine matches that stated on the EC6000 label.
Installing the EC6000 to the machine
The EC6000 is mounted onto the vending machine by hanging it onto three studs
located on the vending machine. To do this you will need to open the
discriminator assembly and line up the mounting keyholes of the EC6000 with the
vending machine studs.
♦Press the yellow button at the top of the EC6000 and gently lift and pull the
discriminator assembly forward. Once open, the mounting keyholes will be
made visible.
♦To securely fix the EC6000 in place, partly unscrew the three machine studs.
♦Line up the three mounting keyholes of the EC6000 with the studs and hang it
in place ensuring that the EC6000 is sitting flat against the machine back
plate.
Label

Page 3 of 9
♦Tighten all three studs and return the discriminator back to its normal position.
Alignment Checks
Once the EC6000 has been securely fitted to the vending machine, check reject
lever operation and coin chute alignment. Do this without any power applied to
the machine.
Cable Connection
The EC6000 is available as either MDB or Executive
with looms/cables to integrate MDB peripheral devices
or Audit devices where available.
Once all relevant cables are connected and before
closing the machine door, tuck any unused cables
away tidily ensuring that none are trapped between the
reject lever mechanism and the vending machine door.
You can now switch ON the power to the vending
machine.
Check there is a minimum 4mm gap between
the machines reject lever mechanism and the
EC6000 reject button.
Press the machine lever a couple of times and
ensure the lid of the discriminator opens and
closes correctly.
Check machine coin chute alignment by inserting
two of each coin denomination through the coin
entry slot of the machine.
Ensure that the inserted coins fall freely into the
EC6000 and exit out into the machines cash
return cup.
4mm
Lid
Lever
Reject
Button

Page 4 of 9
KEYPAD FUNCTIONS
On the front of the EC6000 there is a user interface keypad. The keypad has
three LED’s and five function buttons.
This keypad allows you to dispense coins from the four-tube dispenser, access
service mode and monitor the status of the EC6000.
1 3 LED’s Red, Amber, Green
2 to Dispense coins from coin tubes
3 ‘Mode’ Button Access service mode functions
The LED’s provide a visual indication by light flashes that report the state of the
EC6000. An LED can either be ON, OFF or FLASHING. These light flash codes
can indicate when the EC6000 is operating normally, is in service mode or has a
fault. (Refer to the LED light code section for more information)
The blue keys (marked A to D) have two functions.
When the EC6000 is in idle mode, pressing a blue button on its own will dispense
a coin from that tube. When you press and hold the blue button for approx. 4
seconds, this activates auto dispense (latch dispensing of coins) until the tube is
empty of coins. If however, the yellow (mode) button is pressed, the blue buttons
are then used for the EC6000 service mode.
Service Mode: gives access to the most frequently used product configuration
options. (See Service Mode Options - Page 6)
A D
21
3

Page 5 of 9
GETTING STARTED
At power up, the EC6000 will run a self test, where the EC6000 motor will sound,
the LED’s will cycle five times through a sequence of red, amber & green.
Floating the Coin Tubes
The EC6000 coin tubes should only be filled by inserting coins through the
discriminator.
Any coins that are manually inserted will not be recognised by the EC6000.
Fill Tube using Service Mode
1. Press the Yellow ‘Mode’ button once.
2. Press ‘A’ button and start inserting coins through the discriminator.
3. Only coins required for the tubes will be accepted and the acceptance will
stop when the set float level is reached.
4. Press the Yellow ‘Mode’ button to exit float mode.
Note: MEI recommends that a small number of coins (e.g. 5 of each) be inserted
in each tube prior to leaving the machine.

Page 6 of 9
Service Mode Options (Quick Menu Codes)
This list shows the most commonly used service modes.
Press Following
Button Sequence Description /
Action
Float coin tubes / (Insert coins through the
discriminator – only tube coins will be accepted)
(When finished press the button)
Clear accumulated credit – (Not MDB)
Inhibit a coin / (Insert a coin and then press the reject
lever and then press the button)
Enable a coin / (Insert a coin and then press the
button)
Teach vend price / (Insert coins to the value of the
price and then press the price line button on the
machine to set it)
(When finished press the button)
Note: After teaching a price the changer is
automatically set into price holding mode.
[This feature is only available on Executive products]
Set to ‘Prices Held in VMC’
‘D’ button must be pressed within 6 seconds of the ‘C’
button.
Warning: This will clear all previously set prices.
[This feature is only available on Executive products]
Token Teach (channel 32) / (Insert 32 tokens through
the discriminator. After the 32nd token is inserted the
EC6000 assignes it as a ‘VEND’ token.
Press the button at any time to Cancel token teach
B
A A
A
B
C
D
C D

Page 7 of 9
General LED Light Codes
On - EC6000 OK.
Cycles x 5 - Normal power up sequence.
EC6000 OK.
Blinks Off - Coin accepted / rejected.
Flashing - EC6000 in service mode
On – EC6000 inhibited by VMC.
Flashing - EC6000 requires attention.
(Refer to Amber LED light codes)
Off - No Power to EC6000.
(Check power looms are connected & ensure
power is switched ON)
Alternating - EC6000 Faulty
(Remove from vending machine)
Amber LED Light Codes
If the amber LED flashes, this indicates that a fault has been detected on one of
the EC6000 main modules. These types of fault can be rectified at the machine
and can be for example caused by; a coin jam; dirt built up; or the cassette has
been removed etc. The EC6000 will also indicate the module affected on its
display.
Flashes Check EC6000 Module
1 x Discriminator
2 x Accept gate
3 x Separator module
4 x Dispenser module
A
G
A
G
A
R
R
G
G
A
A
A
A
G

Page 8 of 9
Selecting Predefined Cassette
The EC6000 has stored in memory three predefined tube cassettes that provide
different payout options. (See table below).
Cassette Option Tube A Tube B Tube C Tube D
AA 5c 10c 50c 20c
AB 10c 5c 20c 1E
AC - - - -
The cassette payout is automatically detected by the EC6000 when fitted.
If a different cassette payout is detected by the EC6000 it will automatically begin
to calibrate the cassette. For this reason the new cassette variant must be empty
when first installed.

Page 9 of 9
SAFETY
National & International Standards Conformance
EC6000 products operate at Safety Extra Low Voltage Level (SELV) as defined in
IEC335/EN60335 ‘Safety of Household and Similar Appliances’. They may be
designed into equipment complying with IEC335/EN60335 or IEC950/EN60950
‘Safety of Information Technology Equipment’.
EC6000 products are of Class 3 construction.
Rated Operating Voltage
The operating voltage of a EC6000 is stated on the label attached to the product.
It must not be used with any power source other than that indicated.
Dangerous Environments
The EC6000 must not be operated in the presence of flammable gasses, fumes or
water.
Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly trained persons in order to avoid a hazard.
Access to service areas is restricted to persons with knowledge and training of the
EC6000.
Product Disposal
Do not dispose of any part of a EC6000 by incineration.
EC6000 Start-Up Guide
Revision G2
Publication Date: March 2007
Internet: http://www.meigroup.com
MEI®, and the MEI device are registeredtrademarks.
Copyright MEI UK International Ltd. 2007

Numéro de pièce 793834002 Rev G2
GUIDE D'INITIATION RAPIDE
Rendeur de Monnaie
EC6000
FR
Andere Handbücher für EC6000
2
Inhaltsverzeichnis
Sprachen:
Andere MEI Wechselautomat Handbücher
Beliebte Wechselautomat Handbücher anderer Marken

American Changer
American Changer AC6007 Bedienungsanleitung

American Changer
American Changer AC2007 Bedienungsanleitung

Coinco
Coinco vortex Original Betriebsanleitung

American Changer Corp.
American Changer Corp. AC401-2 Einrichtungshandbuch

Coinco
Coinco Guardian 6000 Bedienungsanleitung

Comestero
Comestero Suzohapp Multi PRO Bedienungsanleitung

Alberici
Alberici Hira 2 Series Bedienungsanleitung

Coinco
Coinco CoinPro 3 Bedienungsanleitung

Hamilton Manufacturing Corporation
Hamilton Manufacturing Corporation DRS Kurzanleitung

Alberici
Alberici HammerOne S11 Bedienungsanleitung

Vetus
Vetus IVPS Technisches Datenblatt

Alberici
Alberici Spike CM Arm Bedienungsanleitung