MrCool Olympus Series Betriebsanleitung

Please read this manual carefully before installation and keep it for future reference.
Due to updates and constantly improving performance, the information and instructions within this
manual are subject to change without notice. Please visit www.mrcool.com/documentation to
ensure you have the latest version of this manual.
Version Date: 10-26-22
Installation & Owner’s
Manual
Olympus Series
Single-Zone (Hyper Heat & E-Star) & Multi-Zone Models

Contents
Page 1 mrcool.com
DISCLAIMER: You are assuming risk by handling materials containing refrigerants under pressure, that
if not handled properly, can cause bodily injury. If you do not feel comfortable conducting this
installation process,we recommend you retain the services of a qualified HVAC professional.
****Electrical work must be completed by a qualified electrical technician.****
!
1
2
3
4Installation Diagram & Line Set Specifications
Single-Zone Line Set Specifications .................................................................................................. 19
Installation Diagram .......................................................................................................................... 18
Multi-Zone Line Set Specifications .................................................................................................... 20
Multi-Zone Air Handler Compatibility Chart ................................................................................... 21
Safety Precautions
Warnings ........................................................................................................................................... 3
Cautions ............................................................................................................................................ 5
Parts Overview
Parts Diagram .................................................................................................................................. 6
Unpacking & Packing Instructions ................................................................................................ 8
Indoor Unit Display ......................................................................................................................... 9
Accessories ............................................................................................................................................ 10
Operating Instructions
Operating Temperature .................................................................................................................. 12
Manual Operation ............................................................................................................................ 12
Airflow Directional Control ............................................................................................................. 13
How the A/C & Heat Pump Work .................................................................................................... 14
Operation Mode Selection ............................................................................................................... 15
Special Functions ............................................................................................................................. 15
Care & Maintenance
Maintenance Precautions ................................................................................................................ 16
Cleaning the Unit .............................................................................................................................. 16
Cleaning the Air FiIter(s) .................................................................................................................. 16
Preparation for Extended Non-Operation ..................................................................................... 17
Preseason Inspection ........................................................................................................................ 17

Contents
Indoor Unit Installation ..................... 22
1. Selecting an installation location ................ 23
2. Attach mounting plate to wall ..................... 24
3. Drill wall hole for connective piping ........... 25
4. Prepare indoor unit piping .......................... 25
5. Hook indoor unit to mounting plate .......... 26
6. Remove indoor unit lower panel ................ 26
7. Connect drain hose & refrigerant piping ... 27
8. Connect signal cable & power cables ......... 29
9. Wrap piping & cables .................................... 30
10. Mount indoor unit ......................................... 31
Outdoor Unit Installation .............. 32
1. Selecting an installation location ........... 33
2. Install drain joint ...................................... 34
3. Anchor outdoor unit ................................ 35
4. Connect refrigerant piping ...................... 35
5. Connect power & signal cables ............... 37
6
Refrigerant Piping Connections ..................................................................... 40
Air Evacuation & Adding Refrigerant ............................................................. 44
Test Run .............................................................................................................. 47
8
9
10
11
5
Page 2mrcool.com
Electrical and Gas Leak Checks ....................................................................... 46
Troubleshooting ................................................................................................ 49
1. Cut pipes ................................................................................................................................. 40
2. Remove burrs ........................................................................................................................... 41
3. Flare pipe ends ......................................................................................................................... 41
4. Connect pipes ......................................................................................................................... 42
• Multi-zone wiring diagrams ................ 39
7
• Common issues .............................................................................................................................. 49
• Troubleshooting ............................................................................................................................. 50
• Wiring/piping self-correction function (Multi-zone systems ONLY) ........................................ 52
12
EU Disposal Guidelines ...................................................................................... 53
• Preparations & precautions ........................................................................................................ 42
• Evacuation instructions ............................................................................................................... 44
• Adding additional refrigerant ..................................................................................................... 45

Page 3 mrcool.com
Read Before Using
Incorrect usage may cause serious damage or injury.
WARNING
CAUTION
DO NOT insert fingers, rods, or other objects into the air inlet or outlet. This could cause injury,
since the fan may be rotating at high speeds.
DO NOT use flammable sprays such as hair spray, lacquer or paint near the unit, as this could
cause fire and/or an explosion.
DO NOT operate the unit in places near or around combustible gases. Emitted gas may collect
around the unit and cause an explosion.
DO NOT allow children to play with the air conditioner. Children must be supervised around
the unit at all times.
DO NOT operate the unit in a room where it could be exposed to excessive amounts of water,
such as a bathroom or laundry room. Exposure to excessive water amounts can cause the
electrical components to short circuit.
DO NOT expose your body directly to direct cool airflow from the unit for a prolonged period
of time.
1. If the unit operates abnormally (emits strange noises or a burning a smell), immediately turn off the
unit and disconnect the power in order to avoid electric shock, fire, and/or injury. Call your local
dealer, or MRCOOL®tech support at (270) 366-0457, for further assistance.
2. If the air conditioner is used together with burners or other heating devices, thoroughly ventilate
the room in order to avoid an oxygen deficiency.
3. In certain functional environments (such as kitchens and server rooms etc.), the use of specially
designed air-conditioning units is highly recommended.
4. This appliance can be used by children (8 years and older) and persons with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge if they have been given instruction
concerning the use of the appliance and understand the hazards involved.
WARNING FOR PRODUCT USE
!
Safety Precautions
The symbols below are used throughout this manual to indicate instructions that should be
followed closely or actions that should be avoided to prevent death, injury, and/or property damage.
This symbol indicates ignoring instructions may cause bodily injury, damage
to the unit, or other surrounding property.
This symbol indicates ignoring instructions may cause death or serious injury.
This symbol indicates that you should NEVER perform the indicated action.
WARNING FOR CLEANING & MAINTENANCE
DO NOT clean the unit with excessive amounts of water.
DO NOT clean unit with combustible cleaning agents, as these could cause deformation and/or
fire.
1. Turn off the device and disconnect the power before cleaning. Failure to do this could result in
electrical shock.
2. Children should not be allowed to play with the appliance or perform cleaning and user maintenance.

Safety Precautions
****ELECTRICAL WORK MUST BE COMPLETED BY A QUALIFIED ELECTRICAL TECHNICIAN****
DO NOT share the power supply with other appliances. An improper or insufficient power
supply could cause fire and/or electrical shock.
DO NOT modify the length of the power supply, or use an extension cord to power the unit.
DO NOT pull the power cord to unplug the unit. Hold the plug firmly and pull it from the outlet.
Pulling directly on the cord could damage it, which can lead to fire or electric shock.
1. The product must be properly grounded during installation or electrical shock could occur.
2. Appropriate wiring standards, regulations, and the installation manual must be followed for all
electrical work.
3. If connecting power to fixed wiring, the following must be incorporated within it, in accordance with
the wiring rules; an all-pole disconnection device (which has at least 3 mm of clearances in all poles),
and have a leakage current that may exceed 10 mA, the residual current device (RCD) having a rated
residual operating current not exceeding 30 mA, all must be present.
4. For all electrical work, fuse the specified cables. Connect cables tightly and clamp them securely to
prevent external forces from damaging the terminal. Improper electrical connections could overheat,
causing fire and/or electrical shock.
5. All electrical connections must be made according to the Electrical Connection Diagram located on the
panels of the indoor and outdoor units.
6. All wiring must be properly arranged to ensure that the control board cover can close properly. If the
control board cover is not properly closed, it can lead to corrosion and cause the connection points on
the terminal to heat up, catch fire, or cause electrical shock.
7. Only use the specified power cord. If the power cord is damaged, it must be replaced by the
manufacturer, its service agent, or a similarly qualified technician in order to avoid a hazard.
8. Keep the power plug clean. Remove any dust or grime that accumulates around the plug as these
could cause electric shock and/or fire.
ELECTRICAL WARNINGS
WARNING FOR PRODUCT INSTALLATION
Page 4mrcool.com
The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection.
The specifications of the fuse are printed on the circuit board.
EXAMPLE: T3.15AL/250VAC,T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC
(for <24,000 Btu/h unit), T30A/250VAC (for >24,000 Btu/h unit), etc.
NOTE: For units with R32 or R290 refrigerant, only the blast-proof ceramic fuse can be used.
TAKE NOTE OF FUSE SPECIFICATIONS
DO NOT install the unit in a location that may be exposed to combustible gas leaks. If
combustible gas accumulates around the unit, it could cause fire.
DO NOT turn on the power until the installation and all work has been completed.
DO NOT install a unit equipped with an auxiliary electric heater within 3 ft (1 m) of any
combustible materials.
1. Installation must be performed by an authorized dealer or specialist. An improper installation can
cause water leakage, electric shock, and/or fire.
2. Installation must be performed according to the installation instructions. Improper installation
could cause water leakage, electrical shock, fire, and could void the warranty. (In North America,
installation must be performed in accordance with the requirements of NEC and CEC by authorized
personnel only.)
3. Contact an authorized service technician for repair or maintenance of this unit. This appliance should
be installed in accordance with national wiring regulations.

Page 5
Safety Precautions
mrcool.com
Note about Fluorinated Gases:
1. This unit contains fluorinated greenhouse gases.
2. For specific information on the type of gas and the amount, please refer to the relevant label on
the unit itself.
3. Service, maintenance, and repair of this unit must be performed by a certified technician.
4. Product un-installation and recycling must be performed by a certified technician.
5. For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2
equivalent or more, but less than 50 tonnes of CO2equivalent, and has a leak-detection system
installed, it must be checked for leaks at least every 24 months.
6. Keeping a record of all leak checks for the lifetime of the unit is strongly recommended.
CAUTION
DO NOT allow the air conditioner to operate for extended periods of time with the doors or
windows open, or in very high humidity.
DO NOT operate the unit with wet hands, as this could cause electric shock.
DO NOT use this device for any other purpose than its intended use.
DO NOT climb onto or place objects on top of the outdoor unit.
1. Turn off the air conditioner and disconnect the power if it is not going to be used for an extended
period of time.
2. Turn off and unplug the unit during storms.
3. Ensure that condensate water can drain smoothly from the unit.
WARNING FOR PRODUCT INSTALLATION (Continued)
4. Only use the included accessories, parts, and specified parts for installation. Using non-standard
parts can cause water leakage, electrical shock, fire, and/or failure of the unit.
5. Install the unit in a firm location that can support the unit’s weight. If the location cannot support the
unit’s weight, or the installation is not done properly, the unit may drop and cause serious injury and
damage.
6. Install the drainage piping according to the instructions in this manual. Improper drainage could
cause water damage to your home and/or property.
7. When moving or relocating the air conditioner, consult experienced service technicians for
disconnection and re-installation of the unit.
8. For detailed information of how to install the indoor and outdoor units to their respective supports,
please refer to the indoor unit installation and outdoor unit installation sections of this manual.
9. Excessive Weight Hazard: Use two or more people when moving and installing the unit. Failure to do
this could result in personal injury.

Page 6
Safety Precautions
mrcool.com
Outdoor Unit
(Exterior/Condenser)
The installation must be performed in accordance with the requirement of local and national
standards. The installation may be slightly different in different areas.
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your unit may vary.
1
Parts Overview
Indoor Unit
(Interior/Air Handler)
Fig. 1.1
NOTE
Wall Mounting Plate
Power Cable (Some Units)
Refrigerant Piping
Signal Cable
Remote Controller
Drainage Pipe
Louver
Remote Controller Holder
(Some Units)
Air Filter (pulls out from top
of the unit)
Front Panel
Outdoor Unit Power Cable
(Some Units)
1
2
3
4
5
6
7
8
9
10
11
Single-Zone System Parts Diagram (E-Star & Hyper Heat)
1
2
3
4
6
7
8910
11
Air-break switch
3
1
2
4
6
7
8
11
55
Humidity
Boos t
(1) (2)

Page 7
Parts Overview
mrcool.com
Fig. 1.2
(A) With wall-mounted type air handler (B) With duct/ceiling type air handler
Indoor unit
1. Panel frame
2. Rear air intake grille
3. Front panel
4. Air purifying filter & Air filter (behind)
5. Horizontal louver
6. LCD display window
7. Vertical louver
8. Manual control button (behind)
9. Remote controller holder
Outdoor unit
10. Drain hose, refrigerant connecting pipe
11. Connective cable
12. Stop valve
13. Fan hood
Indoor unit
1. Air outlet
2. Air inlet
3. Air filter
4. Electric control cabinet
5. Wire controller
Outdoor unit
6. Drain hose, refrigerant connecting pipe
7. Connective cable
8. Stop valve
9. Fan hood
4
Multi-Zone System Parts Diagram
Fig. 1.3
Five Zone
Four Zone
Three Zone
Two Zone
Five Zone
Four Zone
Three Zone
Two Zone

Page 8
Parts Overview
mrcool.com
Indoor unit
1. Drain pump
(drain water from indoor unit)
2. Drain hose
3. Air outlet
4. Air inlet
5. Air-in grill
6. Display panel
7. Remote controller
Outdoor unit
8. Refrigerant connecting pipe
9. Connective cable
10. Stop valve
11. Fan hood
(C) With cassette type air handler
Multi-Zone System Parts Diagram
Fig. 1.4
Five Zone
Four Zone
Three Zone
Two Zone
Instructions for Unpacking & Packing the
Indoor & Outdoor Units
NOTE: Please keep all packaging materials
included with the indoor and outdoor units in
case they are needed for future use.
Unpacking:
Indoor Unit:
1. Carefully cut the sealing tape on the carton with a
knife.
2. Remove the sealing nails on the top of the carton.
3. Open the carton.
4. Take out the middle support plate (if included).
5. Take out the accessory package and connecting
wire (if included).
6. Lift the unit out of the carton and lay it on a flat
surface that is sturdy enough to hold its weight.
7. Remove the left and right packing foam, or upper
and lower packing foam (depending on unit), and
untie the packing bag.
Outdoor Unit:
1. Cut the packing belt.
2. Remove the unit from the carton.
3. Remove the foam from the unit.
4. Remove the packing bag from the unit.
Packing:
Indoor Unit:
1. Put the indoor unit into the packing bag.
2. Attach the left and right package foam, or upper
and lower packing foam (depending on unit) to
the unit.
3. Place the unit into the carton, then put the
accessory bag in.
4. Close the carton and seal it with packaging tape.
Outdoor Unit:
1. Put the outdoor unit into the packing bag.
2. Put the bottom foam into the carton.
3. Place the unit into the carton, then put the upper
packaging foam onto the unit.
4. Close the carton and seal it with packaging tape.

Indoor Unit Display
mrcool.comPage 9
NOTE: Different models will have a different front panel and display window. Not all of the features
listed below will be equipped on the unit you have purchased. Please check the indoor unit display
window of the unit purchased to see which of these features your unit has.
Illustrations in this manual are for explanatory and demonstration purposes only. The actual shape
of your and size of your indoor unit may be different.
Display Code Meanings
or is the temperature display and will also display operational features and
error codes:
will display for 3 seconds when:
• TIMER ON is set (if the unit is OFF, will remain on the display screen
when the Timer On is set).
• SWING, TURBO, SILENCE, or SOLAR PV ECO features are turned on.
will display for 3 seconds when:
• TIMER OFF is set.
• SWING, TURBO, SILENCE, ECO, or BREEZE AWAY features are turned off.
will display when the unit is defrosting (cooling & heating units).
will display when the Active Clean feature is turned on.
will display when 46.4°F (8°C) heating mode is turned on (some units).
will display when ECO mode is activated (some units).
will display when wireless control is activated (some units).
Different versions
of the
Display window
Power Cable
(Some Units) Remote Control
Remote Control
Holder (Some Units)
Louver
Front Panel
Air Filter
(pull up)
(A) (B) (C)
ECO Intelligent Eye
(some units)
Humidity
Boos t
Fig. 1.5
Andere Handbücher für Olympus Series
8
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere MrCool Luftaufbereiter Handbücher

MrCool
MrCool PRODIRECT Series Betriebsanleitung

MrCool
MrCool Signature Series Kurzanleitung

MrCool
MrCool U-match MDUI18060 Bedienungsanleitung

MrCool
MrCool Universal MDUI180 E Series Bedienungsanleitung

MrCool
MrCool Signature MAHM CTA Series Kurzanleitung

MrCool
MrCool Universal Series Bedienungsanleitung

MrCool
MrCool Signature Series Kurzanleitung

MrCool
MrCool Oasis 9k Bedienungsanleitung

MrCool
MrCool Olympus Series Bedienungsanleitung

MrCool
MrCool Olympus Series Bedienungsanleitung