SECTION 1
SUMMARY
CONTENTS
PRODUCT SAFETY SERVICING GUIDELINES FOR AUDIO PRODUCTS
............. 1-2
SERVICING PRECAUTIONS ...........................................................................1-3
• General Servicing Precautions
• Insulation Checking Prodedure
• Electrostatically Sensitive Devices
SPECIFICATIONS ........................................................................................... 1-6,7
1-1
ALIGNMENT PROCEDURE ............................................................................. 1-4,5
• POWER DRIVEN VOLTAGE
• IDLING CURRENT
• BALANCE INPUTS CMRR

1-2
SUBJECT: GRAPHIC SYMBOLS
PRODUCT SAFETY SERVICING GUIDELINES FOR AUDIO PRODUCTS
A.C. VOLTMETER
GOOD EARTH GROUND
SUCH AS THE WATER
PIPE. CONDUIT. ETC
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
CAUTION : DO NOT ATTEMPT TO MODIFY THIS
PRODUCT IN ANY WAY, NEVER PERFORM CUSTOM-
IZED INSTALLATIONS WITHOUT MANUFACTURER’S
APPROVAL. UNAUTHORIZED MODIFICATIONS WILL
NOT ONLY VOID THE WARRANTY, BUT MAY LEAD TO
YOUR BEING LIABLE FOR ANY RESULTING PROP-
ERTY DAMAGE OR USER INJURY.
SERVICE WORK SHOULD BE PERFORMED ONLY
AFTER YOU ARE THOROUGHLY FAMILIAR WITH ALL
OF THE FOLLOWING SAFETY CHECKS AND SERVIC-
ING GUIDELINES. TO DO OTHERWISE,INCREASES
THE RISK OF POTENTIAL HAZARDS AND INJURY TO
THE USER.
WHILE SERVICING, USE AN ISOLATION TRANS-
FORMER FOR PROTECTION FROM A.C. LINESHOCK.
SAFETY CHECKS
AFTER THE ORIGINAL SERVICE PROBLEM HAS
BEEN CORRCTED. A CHECK SHOULD BE MADE OF
THE FOLLOWING.
SUBJECT : FIRE & SHOCK HAZARD
1.BE SURE THAT ALL COMPONENTS ARE POSI-
TIONED IN SUCH A WAY AS TO AVOID POSSIBILITY
OF ADJACENT COMPONENT SHORTS.THIS IS ESPE-
CIALLY IMPORTANT ON THOSE MODULES WHICH
ARE TRANSPORTED TO AND FROM THE REPAIR
SHOP.
2. NEVER RELEASE A REPAIR UNLESS ALL PROTEC-
TIVE DEVICES SUCH AS INSULATORS, BARRIERS,
COVERS, SHIELDS, STRAIN RELIEFS, POWER
SUPPLY CORDS, AND OTHER HARDWARE HAVE-
BEEN REINSTALLED PER ORIGINAL DESIGN. BE
SURE THAT THE SAFETY PURPOSE OF THE POLAR-
IZED LINE PLUG HAS NOT BEEN DEFEATED.
3. SOLDERING MUST BE INSPECTED TO DISCOVER
POSSIBLE COLD SOLDER JOINTS, SOLDER
SPLASHES OR SHARP SOLDER POINTS. BE CER-
TAIN TO REMOVE ALL LOOSE FOREIGN PARTICLES.
4. CHECK FOR PHYSICAL EVIDENCE OF DAMAGE
OR DETERIORATION TO PARTS AND COMPONENTS.
FOR FRAYED LEADS, DAMAGED INSULATION
(INCLUDING A.C. CORD). AND REPLACE IF NECES-
5. NO LEAD OR COMPONENT SHOULD TOUCH A
RECIVING TUBE OR A RESISTOR RATED AT 1 WATT
OR MORE. LEAD TENSION AROUND PROTRUNING
METAL SURFACES MUST BE AVOIDED.
6. ALL CRITICAL COMPONENTS SUCH AS FUSES,
FLAMEPROOF RESISTORS, CAPACITORS, ETC.
MUST BE REPLACED WITH EXACT FACTORY TYPES,
DO NOT USE REPLACEMENT COMPONENTS OTHER
THAN THOSE SPECIFIED OR MAKE UNRECOM-
MENDED CIRCUIT MODIFICATIONS.
7. AFTER RE-ASSEMBLY OF THE SET ALWAYS PER-
FORM AN A.C. LEAKAGE TEST ON ALL EXPOSED
METALLIC PARTS OF THE CABINET, (THE CHANNEL
SELECTOR KNOB, ANTENNA TERMINALS. HANDLE
AND SCREWS) TO BE SURE THE SET IS SAFE TO
OPERATE WITHOUT DANGER OF ELECTRICAL
SHOCK. DO NOT USE A LINE ISOLATION TRANS-
FORMER DURING THIS TEST USE AN A.C. VOLTME-
TER, HAVING 5000 OHMS PER VOLT OR MORE SEN-
SITIVITY, IN THE FOLLOWING MANNER; CONNECT A
1500 OHM 10 WATT RESISTOR, PARALLELED BY A
.15 MFD. 150.V A.C TYPE CAPACITOR BETWEEN A
KNOWN GOOD EARTH GROUND (WATER PIPE,
CONDUIT,ETC.) AND THE EXPOSED METALLIC
PARTS, ONE AT A TIME. MEASURE THE A.C. VOLT-
AGE ACROSS THE COMBINATION OF 1500OHM
RESISTOR AND .15 MFD CAPACITOR. REVERSE THE
A.C. PLUG AND REPEAT A.C. VOLTAGE MEASURE-
MENTS FOR EACH EXPOSED METALLIC PART. VOLT-
AGE MEASURED MUST NOT EXCEED 75 VOLTS
R.M.S. THIS CORRESPONDS TO 0.5 MILLIAMP A.C
ANY VALUE EXCEEDING THIS LIMIT CONSTITUTES A
POTENTIAL SHOCK HAZARD AND MUST BE COR-
RECTED IMMEDIATELY.
THE LIGHTNING FLASH WITH APROWHEAD SYMBOL. WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED
TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE”
THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK.
THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE SERVICE
PERSONNEL TO THE PRESENCE OF IMPORTANT SAFETY INFORMATION IN SERVICE LITERATURE.

SERVICING PRECAUTIONS
CAUTION:Before servicing the Stereo amplifier covered by
this service data and its supplements and addends, read and
follow the SAFETY PRECAUTIONS. NOTE: if unforeseen
circumstances create conflict between the following servicing
precautions and any of the safety precautions in this publication,
always follow the safety precautions.
Remember Safety First:
General Servicing Precautions
1. Always unplug the Stereo amplifier AC power cord from the
AC power source before:
(1) Removing or reinstalling any component, circuit board,
module, or any other assembly.
(2) Disconnecting or reconnecting any internal electrical
plug or other electrical connection.
(3) Connecting a test substitute in parallel with an electrolytic
capacitor.
Caution: A wrong part substitute or incorrect polarity
installation of electrolytic capacitors may result in an
explosion hazard.
2. Do not spray chemicals on or near this Stereo amplifier or
any of its assemblies.
3. Unless specified otherwise in this service data, clean
electrical contacts by applying an appropriate contact
cleaning solution to the contacts with a pipe cleaner,
cottontipped swab, or comparable soft applicator.
Unless specified otherwise in this service data, lubrication
of contacts is not required.
4. Do not defeat any plug/socket B+ voltage interlocks with
which instruments covered by this service manual might be
equipped.
5. Do not apply AC power to this Stereo amplifier and/or any
of its electrical assemblies unless all solid-state device heat
sinks are correctly installed.
6. Always connect test instrument ground lead to the
appropriate ground before connecting the test instrument
positive lead. Always remove the test instrument ground lead
last.
Insulation Checking Procedure
Disconnect the attachment plug from the AC outlet and turn the
power on. Connect an insulation resistance meter (500V) to the
blades of the attachment plug. The insulation resistance
between each blade of the attachment plug and accessible
conductive parts (Note 1) should be more than 1 M-ohm.
Note 1: Accessible Conductive Parts including Metal panels,
Input terminals, Earphone jacks, etc.
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged
easily by static electricity. Such components commonly are
called Electrostatically Sensitive (ES) Devices. Examples of
typical Es devices are integrated circuits and some field effect
transistors and semiconductor chip components.
The following techniques should be used to help reduce the
incidence of component damage caused by static electricity.
1. Immediately before handing any semiconductor component
or semiconductor-equipped assembly, drain off any
electrostatic charge on your body by touching a known earth
ground. Alternatively, obtain and wear a commercially
available discharging wrist strap device, which should be
removed for potential shock reason prior to applying power to
the unit under test.
2. After removing an electrical assembly equipped with ES
devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or
exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder
ES devices.
4. Use only an antistatic solder removal device. Some solder
removal devices not classified a “anti-static” can generate
electrical charges sufficient to damage ES devices.
5. Do not use freonpropelled chemicals. These can generate
electrical charge sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective
package until immediately before you are ready to install it.
(Most replacement ES devices are packaged with leads
electrically shorted together by conductive foam, aluminum
foil, or comparable conductive material).
7. Immediately before removing the protective material from the
leads of a replacement ES device, touch the protective
material to the chassis or circuit assembly into which the
device will be installed.
Caution: Be sure no power is applied to the chassis or circuit,
and observe all other safety precautions.
8.Minimize bodily motions when handing unpackaged
replacement ES devices. (Normally harmless motion such as
the brushing together of your clothes fabric or the lifting of
your foot from a carpeted floor can generate static electricity
sufficient to damage an ES device.)
1-3

321 123
ALIGNMENT PROCEDURE
A. POWER DRIVEN VOLTAGE(PSU BOARD)
Connect a DC Millivoltmeter to TP601/TP701 1 and 2 pin, then adjust VR601/VR701(6.8kohms)
for 0V±0.1V.
B. IDLING CURRENT(AMP BOARD)
1.Connect a DC Millivoltmeter betweenTP301 2 pins, then adjust VR301 (200ohms) for 7-8mV
reading on meter.
2.Connect a DC Millivoltmeter between TP401 2 pins, then adjust VR401 (200ohms) for 7-8mV
reading on meter.
3. Watch for 10minutes, to make sure it is arround 7mV
PSU BOARD
AMP BOARD(L/R)
1-4

C. BALANCE INPUTS CMRR
1.Volum set 0dB, Input 2V/10KHZ common mode sinwave signal at L channel Balance input,Connect a AC
Millivoltmeter to preout1L then adjust R565 for lowest output level.
2. Volum set 0dB,Input 2V/10KHZ common mode sinwave signal at R channel Balance input,Connect a AC
Millivoltmeter to preout1R then adjust R564 for lowest output level.
1-5

Power Amplifier Section
Continuous output power into 4/8 ohms 180W (17dBw)
(Minimum RMS power per channel, both channels
driven, With no more than the rated distortion)
Rated distortion (THD)(20Hz –20kHz) İ0.004%
Channel Separation ı100dB
(MAIN IN, 60W Out at 8,1kshorted, 1kHz)
Clipping power, 1kHz 220W
(Maximum continuous power per channel)
Dynamic Headroom at 8 ohms 4.2dB
Dynamic power 8ohms ı280W
(Maximum short-term power per channel ) 4ohms ı480W
2ohms ı785W
Damping factor ı150
Signal to noise ratio(refer 1W A-weighted) ıı100dB
Slew rate ıı20V/ȝsec
T.H.D and SMPTE I.M. İ0.01%
(Distortion from 250mW to rated output)
IHF I.M. (CCIF IM) and T.I.M distortion İ0.005%
(From 250mW to rated output))
Input impedance 20k//680pF
Input sensitivity rate power into 8ohms)roF( 1.38V
Power amp gain 29dB
Preamplifier Section
Input Impedance single-ended input 150k//500pF
SPECIFICATIONS
NAD M3 INTEGRATE AMPLIFIER
Note: Specifications are measured in accordance with EIA
Standard RS-490 (IHF A-202) for amplifiers
1-6
balanced input 120kS)

Signal-to-Noise ratio 110dB ref 500mV
(A-weighted, line In, Pre-Out)
Rated distortion (THD)(20Hz –21kHz) İ0.005%
Channel Separation ı110dB
(1kHz 2V Line/balanced IN, 2V Pre-Out)
Input Sensitivity 320mV for 2V out
Input Overload Line input
Balanced input
ı10V
Frequency response(5Hz-70KHz) <+/-0.3dB
THD (SUB OUT) İ0.01%
(2V CD in, 2V SUB out; 50Hz, 80kHz LPF)
THD (ZONE 2 OUT)
(2V CD IN, 1kHz, 80kHz LPF) İ0.01%
Outputs
Preamp output impedance
Zone2 output impedance
Controls
Treble ±5dB at 10kHz
Bass ±5dB at 100Hz
Pre-in ,Power AMP out,input 2V
Signal-to-Noise ratio, A-weighted 107dB ref 1 W out
(500mV CD in, SPK out, 8, A weighted)
Rated distortion (THD)(20Hz –20kHz) İ0.008%
Input sensitivity 450mV
(CD in, SPK out, at rated power, volume max.)
Channel Separation ı100dB
(CD in, 20W out at 8, 1kshorted, 1kHz)
Frequency response Bd3.0-/+
1-7
ı9 V
PHYSICAL SPECIFICATIONS
Dimensions(W x H x D)
Net 17.2x5.3x15.2”(435x135x386mm)
Gross 17.2x5.8x17.2”(435x147x435mm)
Net Weight 51.8lbs(23.5kg)
Shipping Weight 68.3lbs(31.0kg)

2-1
SECTION 2
CABINET & MAIN CHASSIS
CONTENTS
EXPLODED VIEWS.................................................................................. 2-2
1. Cabinet and main frame section...................................................................2-2
2. Packing accessory section............................................................................. 2-3
3. Exploded view parts list................................................................................. 2-4,5
Andere Handbücher für Masters M3
2
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere NAD Verstärker Handbücher

NAD
NAD C 352 Bedienungsanleitung

NAD
NAD M33 Bedienungsanleitung

NAD
NAD C 245BEE Bedienungsanleitung

NAD
NAD C 338 Bedienungsanleitung

NAD
NAD S250 Bedienungsanleitung

NAD
NAD C275BEE C/AH Bedienungsanleitung

NAD
NAD C3050 Bedienungsanleitung

NAD
NAD T 977 Bedienungsanleitung

NAD
NAD T163 Montage- und Bedienungsanleitung

NAD
NAD C 399 Bedienungsanleitung