NANO 3 N2 Series Bedienungsanleitung

NITROGEN GENERATOR
SERIES 3 N² USER GUIDE:

Page 2
nano-purification solutions.
17-110-0142
Document Contents
Title
1. General Information
1.1 Document Introduction
1.2 Support & Manufacturer’s Details
2. General Safety
3. Description of the Product
3.1 Technical Description
4. Product Contents
4.1 Packaging
4.2 Un-packing the equipment
5. Product Dimensions
6. Equipment Overview
7. System Layout
7.1 Site Location
7.2 Mechanical Installation
7.3 Electrical Installation
8. Generator Operation
8.1 6 Pin Electrical Connector Configuration
8.2 Start Up Procedure
8.3 Shut Down Procedure
8.4 Economy Mode
9. Oxygen Analyser Calibration
10. Maintenance
10.1 Daily Checks
10.2 Cleaning
10.3 Service Schedule
10.4 O2Sensor Calibration
11. Troubleshooting
12. Warranty
13. Service Record
Page
3
3
3
4
5
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18
19
21
21
21
22
22
23
24
25

Page 317-110-0142
1. General Information
This manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent
in writing from nano-purification solutions. It may not be distributed through the internet or computer bulletin
board systems without prior consent from nano-purification solutions.
1.1 Document Introduction
This manual provides factory prescribed procedures for the installation, operation and maintenance of a nano-
purification solutions Series 3 Nitrogen Generator. The procedures illustrated in this document are only to be
performed by authorized personnel. For further information regarding the procedures outlined in this document
contact nano-purification solutions before proceeding.
Read this document carefully before attempting to install or operate the generator . This document should be
permanently available at the generator installation site and be kept in an easily accessible place alongside the
product.
©2012 nano-purification solutions.
Series 3 Nitrogen Generator
Document number: 17-110-0142
Issue: 001
NOTES: highlight important sections of information where particular care and attention should
be paid.
CAUTIONS: indicate any situation or operation that may result in potential damage to
the product, injury to the user, or render the product unsafe.
Annotations:
1.2 Support
For North American Support please contact:
nano-purification solutions
11330 Vanstory Drive
Huntersville, NC 28078
USA
Telephone: (704) 897-2182
Fax: (704) 897-2183
Internet: www.n-psi.com
E-mail: [email protected]
Manufacturer’s Details
nano-porous solutions limited
Dukesway, Team Valley. Trading Estate,
Gateshead, Tyne and Wear,
United Kingdom, NE11 OPZ.
Telephone: +44 (0) 191 497 7700
Fax: +44 (0) 191 497 7709
Internet: www.n-psl.com
E-mail: [email protected]

Page 4
nano-purification solutions.
17-110-0142
2. General safety
For your own safety, when carrying out work on this product, all relevant national safety
regulations must be complied with relating to pressurized and electrical systems.
Intended use of the Product
The generator is exclusively intended for the production of N2 from compressed air, which is free from bulk
water, oil and solid matter constituents.
The product should be sited within a building and protected (see section 7.1 Site selection). The generator
must be operated only in accordance with the data on the rating label and in accordance with the contractual
conditions. Any operations that do not comply with those stated on the product rating label will render the
warranty void.
This product is only designed to operate at pressures of between 87 - 145 psig (6 - 10 barg).
It is not suitable for pressures in excess of 145 psig (10 barg).
No modifications must be made to the product. Any modifications may reduce the operational safety of the
product and invalidate the manufacturer’s warranty, potentially resulting in damage to the product and serious
personal injury.
Personnel
Only authorized, competent and trained personnel are permitted to work on the product. This user guide is
intended solely for such personnel and is to be used only as a reference; it should not be used to replace
conventional training.
Safe handling
Please ensure the relevant safe engineering practices and handling procedures are employed when handling,
installing and operating the product. Ensure that the equipment is depressurized and electrically isolated, prior
to carrying out any of the scheduled maintenance instructions specified within this user guide.
A suitable lifting aid must be used to minimize the risk of physical injury or damage to the
product.
IMPORTANT: It is essential that the system into which the product is in-
stalled is fitted with a pressure limiting/relief device. This device should
be between the compressor and the generator. The device must be set to
prevent the maximum working pressure of 145 psig (10 barg) from being
exceeded.

Page 517-110-0142
Inlet pressure dewpoint required is ISO8573.1 Class 5 for water 45°F (+7°C)
3 stage inlet filtration is required , e.g. Water separator and 2 high efficiency coalescer filters (see system
layout on page 11) to protect the generator from bulk water, particulate and oil aerosol.
3. Description of Product
3.1 Technical Specification
The n-psi nitrogen generator operates on the Pressure Swing Adsorption (PSA) principle to produce a continuous
stream of nitrogen gas from clean dry compressed air.
Pairs of dual chamber extruded aluminium columns, filled with Carbon Molecular Sieve (CMS), are joined via
an upper and lower manifold to produce a two bed system. Compressed air enters the bottom of the ‘online’
bed and flows up through the CMS. Oxygen is preferentially adsorbed by the CMS, allowing nitrogen to pass
through.
After a pre-set time the control system automatically switches the bed to regenerative mode and oxygen is
vented from the CMS. A small portion of the outlet nitrogen gas is expanded into the bed to accelerate the
regeneration. At the same instant the second bed comes on-line and takes over the separation process.
The CMS beds alternate between separation and regeneration modes to ensure continuous and uninterrupted
nitrogen production.
When a generator is specified with an internal dryer, each CMS column has a unique adsorbtion media tube
(AMT) technology dryer fitted into the bottom of each column.
The unique AMT dryer does not require servicing and the life is aligned to the CMS material.
The internal AMT dryer reduces energy running costs by elminating the additional external dryer purge (typically
20-25% of the dryer inlet air consumption) and the associated pressure loss across an external dryer. The
compressed air supply is also reduced accordingly.
The oxygen concentration in the nitrogen stream is monitored continuously on models fitted with an oxygen
analyser. If the outlet concentration exceeds the required production level, the nitrogen outlet is closed and the
gas is vented to atmosphere. Normal operation will resume when the purity recovers.
Parameter Units
Inlet Air Quality ISO 8573.1:2010 Class 1.2.1 / Class 1.5.1 (when fitted with AMT integral dryer)
Minimum Inlet Pressure psig / (Barg) 88 (6)
Maximum Inlet Pressure psig / (Barg) 145 (10)
Rated Inlet Temperature °F / (°C) 68-77 (20-25)
Minimum Inlet Temperature °F / (°C) 34.7 (1.5)
Maximum Inlet Temperature °F / (°C) 104 (40) - Subject to correction factor.
Supply Voltage VAC (50/60Hz) 88-264 VAC
Input Current Amps (VAC) 1.3 / 0.8 (110-230)
IP Rating IP54 / NEMA 3
Noise dB (A) <80

Page 6
nano-purification solutions.
17-110-0142
4. Product Contents
1. Series 3 N² Nitrogen Generator
2. Documentation
• 1 x User Guide
• 1 x Declaration of Conformity
3. Packaging
• 1 x Generator support base and box cover
• Care Should be taken and inspection undertaken during unpacking to ensure that the product is
not damaged.
• Verify that all component parts have been supplied with the generator

Page 717-110-0142
4.1 Packaging
All products are securely packaged in a bespoke wooden packing box. The generator will be held in a
horizontal position by wooden struts; using straps to secure the product to the box base. The box top cover
can be removed by removing the 4 fixing screws and lifting off in one piece.
The support packing box permits longitudinal stacking; however the central section of the packing
box should not be considered load bearing.
Damage to the packaging
• Check immediately to establish whether damage has occurred to the external packaging and if the
damage extends to the product inside.
• If there is damage to a product, contact the relevant supplier immediately.
In no circumstances must a damaged product be used in operation. Using damaged
products can lead to irreparable functional faults or cause serious physical harm.

Page 8
nano-purification solutions.
17-110-0142
6
43
1 2
5
4.2 Unpacking the Equipment
The generator is supplied in a wooden crate. It is recommended that the crate be moved into position using a
forklift truck or pallet truck. Remove the generator from the wooden crate using an overhead crane. Use the
following illustrations for correct guidance on safe handling and lifting techniques.

Page 917-110-0142
Front Side
5. Product Dimensions
D
E
C
A
F
G
B
H
I
* DEPENDING ON MODEL
MODEL CONNECTION
SIZE
A
ins [mm]
B
ins [mm]
C
ins [mm]
D
ins [mm]
E
ins [mm]
F
mm [ins]
G
ins [mm]
H
ins [mm]
I
ins [mm]
WEIGHT
lbs [KG]
NNG-2110 1/2” 26 [650] 15 [382] 47 [1210] 15.7 [400] 14.2 [360] 10 [262] - - 40 [1009] 242 [110]
NNG-2130 1/2” 26 [650] 15 [382] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 365 [116]
NNG-3110 1/2” 32 [820] 22 [550] 47 [1210] 15.7 [400] 14.2 [360] 10 [262] - - 40 [1009] 374 [170]
NNG-3130 1/2” 32 [820] 22 [550] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 490 [222]
NNG-4130 1/2” 39 [990] 28 [718] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 610 [277]
NNG-6130 1/2” 52 [1320] 41 [1054] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 852 [387]
NNG-8130 1/2” 65 [1660] 55 [1390] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 1100 [499]
NNG-10130 *1/2” or 1” 79 [2000] 68 [1726] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 1350 [610]
NNG-12130 *1/2” or 1” 92 [2330] 80 [2026] 71 [1810] 15.7 [400] 14.2 [360] 10 [262] 22 [560] 36 [920] 64 [1625] 1600 [722]

Page 10
nano-purification solutions.
17-110-0142
6. Equipment Overview
Compressed
Air Inlet
To Buffer
Vessel
From Buffer
Vessel
Nitrogen
Outlet
N² Outlet Port to buffer
All connection points are clearly marked on the generator and are represented in the diagram below. Ports 1-4
are factory set for customer requirement but can be changed internally.
Controller Display Unit Front Shroud
N² Outlet Port
Column A pressure gauge
Column B pressure gauge
N² Outlet pressure gauge
Air inlet pressure gauge
External O² Analyser Sample Point
N² Inlet Port from buffer
Air Inlet Port
5
2
6
3
4
2
1
3
7
8
4
1
1
5 6
3
7 8
2
4
Top Cover
9
9
(1/4” bspp)
Sample
Dieses Handbuch passt für folgende Modelle
9
Inhaltsverzeichnis
Andere NANO Tragbarer Generator Handbücher