Nedap VP1007 Bedienungsanleitung

Service manual
For installation, operation and service
ISO Reader I/O
VP1007
April 2009 / Manual version 0.4

VP1007-200PM-00 ISO Reader I/O Manual version 0.4
Version overview
Manual version 0.4 / 4 - 2009
This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no
license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and
availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in
part, without the written consent of the publisher.
© Nedap N.V., AGRI P.O. Box 104 NL-7140 AC GROENLO The Netherlands

VP1007-200PM-00 ISO Reader I/O Manual version 0.4
VP1007 ISO Reader I/O
Contents
1Introduction 1
2Description and functioning 2
3Safety 3
4Installation 3
4.1 Mounting 3
4.2 Connections 4
5Adjustments 5
5.1 Check after power up 5
5.2 Address 5
5.3 Antenna 6
5.4 Software setup 6
6Advanced 7
6.1 Testing inputs and outputs 7
6.2 Advanced antenna adjustment 7
6.3 Identification test options 8
7Trouble shooting 9
8Maintenance, cleaning and disposal 10
Appendix A: Specifications 11
Appendix B: Display and push button 12
Appendix C: Overview display menu 13
Appendix D: LED indicator overview 14
Appendix E: RS485 connection 15
Appendix F: RS232 connections 16

VP1007-200PM-00 ISO Reader I/O Manual version 0.4

VP1007-200PM-00 ISO Reader I/O Manual version 0.4 / Page 1
Preface
This manual is part of the service documentation for Nedap Velos. Reference is also made to other
manuals that are part of the Nedap Velos documentation. For an overview of available Nedap Velos
manuals see the manual “Nedap Velos General Description”, or visit the Nedap Agri website
www.nedap-agri.com.
1 Introduction
The Velos VP1007 is used for identification of animals for feeding, weighing, milking, heat detection
etc. The VP1007 must be connected to a computer (controller) and can communicate by a CAN,
RS485 or RS232 protocol. The connected computer must give controlling commands to the VP1007 to
operate inputs, outputs and identification.
The VP1007 has the following main tasks:
- Identification of tags (ISO 134.2 kHz FDX/HDX)
Two antenna connections available, 1 active at the time
- Controlling outputs
5 outputs are available to activate e.g. lights, motors, valves, relays
5 protected outputs for continues 25V, e.g. power for sensors
- Reading inputs
5 inputs available for e.g. sensors, switches
- Communication
RS232 or RS485 to connect e.g. a weigh computer
Following antenna types can be used: V-sense antennas
The VP1007 must be installed in a housing suitable for farm conditions, for example in a V-box.
Reference manuals : PS0000-200PM-00 Velos general description
VP1007 VP1007
VP1007 VP1007
VPU To PC (LAN ethernet)
CAN-bus channel 1
CAN-bus channel 2
Power
Supply
max 3m
Max number of V-packs and cable length depends on configuration used

VP1007-200PM-00 ISO Reader I/O Manual version 0.4 / Page 2
Compliance statement (part 15.19)
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Warning (part 15.21)
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
2 Description and functioning
A VP1007 has 5 inputs used for reading e.g. sensors or switches.
There are also 5 outputs available to activate e.g. lights, motors, valves or relays.
The VP1007 can read tags FDX/HDX 134.2 kHz.
The VP1007 must be connected to a computer and can communicate by a CAN, RS485 or RS232
protocol. The connected computer must give controlling commands to the VP1007 to operate inputs,
outputs and identification.
Figure : Sticker on the VP1007 with indication of the connections
Operation of the VP1007
Antenna : for reading tags, normally on
Inputs : read continuously with status change sent to the controller
Outputs : switched on or off by commands from the controller
LEDs : switched on or off by the VP1007 according to the status
Error : errors are sent to the controller
All inputs and outputs can be tested by the use of the push button and display. For operation of the
push button and display see appendix B.

VP1007-200PM-00 ISO Reader I/O Manual version 0.4 / Page 3
3 Safety
Installation and service only by trained personnel.
Always turn off the main power when working on the electrical installation.
4 Installation
Installation consits of the following steps:
1. Mounting
2. Installation of all wiring (connections)
3. Power up
4. Set address (when more then one VP1007)
5. Check antenna adjustment (green LED on)
6. Check the connected equipment like lamps, motors, sensors etc.
7. Configuration in the PC
Follow this manual to complete the steps.
4.1 Mounting
See the relevant equipment manual relating to where the VP1007 is to be installed.

VP1007-200PM-00 ISO Reader I/O Manual version 0.4 / Page 4
4.2 Connections
See the relevant equipment manual relating to where the VP1007 is to be installed.
Figure : I/O of the VP1007. The input and output connections are shown above as an example.
Details VP1007 inputs and outputs
Vin + Power
- Minus
RS232 / 485 RxD / B- Data receive
TxD / A+ Data send
- / Minus for RS232 / shield for RS485
SYNC ~ Synchronisation for HDX, AC (no plus or minus, cable must be twisted pair)
~ See above
I/O 1 .. 5 + Output max 400mA
O Output max 400mA / 1.7A input
- Minus for output (O) and minus input (I)
I Input
ANTENNA + Antenna
F SYNC FI/FO Frequency synchronisation FI=in FO=out
- Antenna minus (shield of coax cable)
IMPORTANT : Use power supply with a fused output such as Velos VP2001, VP2002.
Details Velos cable
oran
g
e
blue white
blue
black
red
orange white
Velos cable
Switch
Light
Velos cable OUT
(
same connection as IN
)
Red (+)
Black (-)
Blue (Ch)
Blue/white (Cl)
Shield
Orange (Sync)
Orange/white (Sync)
Shield
Power
1,5 mm2
Communication
0,34 mm2
Twisted pair shielded
HF Synchronisation
0,34 mm2
Twisted pair shielded
Part No. 7705310

VP1007-200PM-00 ISO Reader I/O Manual version 0.4 / Page 5
5 Adjustments
Before starting with adjustments first install all components and wiring. Follow the sequence as
indicated in this chapter.
5.1 Check after power up
Check if the VP1007 has power after power up. This means 3 green LED’s are on, see figure below.
For more details about the LED indicators see Appendix D.
If LED’s are green, continue with address settings
5.2 Address
Each VP1007 requires a unique address on the communication bus. Use the display and push button
to set the address. How to use the display and push button is shown in appendix B. See appendix C
for the complete overview of the display menu.
The display will indicate the actual address at startup (01 for a new unit). If an address is accepted by
the communication bus the display goes blank. If there is no communication with the controller also the
address is shown. If the address is not accepted, the display will show the address.
How to change an address (for example set address to 12)
1. Short press on the button. Ad will appear.
2. Now hold the button till the display starts blinking. dA will appear.
3. Short press on the button. SA will appear.
4. Now hold the button until the display starts blinking. 0- will appear.
5. Short press on the button. The 0- is now changed into 1-.
6. Hold the button until the display starts blinking. 10 will appear.
7. Short press on the button. The 10 is now changed into 11.
8. Short press on the button again. The 11 is now changed into 12.
9. Hold now the button until the display starts blinking. The 12 is now stored in the memory.
10. There will now be 12 blinking on the display now. If the address is accepted by the process
unit the display goes blank.
How to check the address
1. Short press the button. Ad will appear.
2. Now hold the button until the display starts blinking. dA will appear.
3. Hold the button again until the display starts blinking. The actual address will be shown.
4. Leave the menu by pressing the button until the display goes blank.
If the display does not go blank (address remains on the display), the address in not accepted.
When the address setting is ok continue with the antenna adjustment.

VP1007-200PM-00 ISO Reader I/O Manual version 0.4 / Page 6
5.3 Antenna
After power up the antenna tuning starts automatically. LEDs are indicating the status.
Green on Antenna tuning ok
Red on Antenna out of range
Red on Antenna out of range
Red blinking No antenna connected or low antenna signal
All off Antenna switch off by the software
5.4 Software setup
The software in the connected controller determines how the inputs and outputs on the VP1007 are
controlled. See manual with the relevent settings to configure the software for this VP1007.
When the software setup is done the VP1007 is ready for use.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte E/A-System Handbücher anderer Marken

WAGO
WAGO 750-344 Bedienungsanleitung

Teknim
Teknim TWM-1887 Bedienungsanleitung

Intelligent Appliance
Intelligent Appliance IA-2662-E Bedienungsanleitung

BERGHOF
BERGHOF ECC DIO 16/16 Bedienungsanleitung

Advantech
Advantech PCM-27J3AU Installations- und Betriebshandbuch

Festo
Festo CP-E08-M12-CL Bedienungsanleitung