NESS R8
INSTALLER MANUAL
Revision 2, October 2002
Document Part Number: 890–273
For product:
100–690 Ness R8 Control Panel
© 2002 Ness Security Products Pty Ltd ABN 28 069 984 372
R8 installer rev2 pmo091002
Specifications may change without notice.
NESS SECURITY PRODUCTS
TELECOMMUNICATIONS COMPLIANCE
Australian Communications Authority

Introduction ..................................................................................................................... 4
Compatibility ................................................................................................................... 5
INSTALLATION ................................................................................................................ 6
Power up procedure ....................................................................................................... 6
Connection Diagram ....................................................................................................... 8
Inputs / Outputs .............................................................................................................. 9
R8 Keypad ..................................................................................................................... 10
Audible & Visual feedback ..................................................................................... 10, 11
User Tests ......................................................................................................................11
OPERATION .................................................................................................................. 12
Operation Summary ..................................................................................................... 13
Alarm Type Descriptions .............................................................................................. 14
System Alarm Descriptions .......................................................................................... 15
Quick Start Panel Programming .................................................................................. 16
Quick Start RADIO Programming ................................................................................ 17
PROGRAMMING ........................................................................................................... 19
How to enter Program Mode ........................................................................................ 19
PANEL PROGRAMMING OPTIONS ........................................................................ 20-35
DIALLER PROGRAMMING OPTIONS ..................................................................... 37-43
FACTORY DEFAULT OPTIONS .................................................................................... 45
CENTRAL STATION MONITORING .............................................................................. 48
Contact ID reporting codes .......................................................................................... 48
Ness Accessories ......................................................................................................... 50
Ness Radio Products .................................................................................................... 51
PROGRAM OPTIONS SUMMARY ........................................................................... 52-55
CONTENTS

Ness R8 - Installation and Programming Manual
4
The Ness R8 is a new and unique fully self-contained radio control panel.
The panel has a built-in keypad for programming and user operation, a built-in piezo siren, built-
in LCD display, built-in radio receiver, built-in battery backup and built-in dialler.
The R8 supports up to 8 Ness radio PIRs and up to 14 Ness Radio Keys. All Ness supervised and
encrypted radio devices are supported. There is even a Doorbell feature with selectable tunes
when used with the Ness Radio Doorbell transmitter.
In addition to radio devices, the R8 has 1 hardwired zone and 1 hardwired tamper input for
connection of a wired detection device and external siren cover tamper switch.
The built-in piezo siren provides high volume audible warning. The R8 also has Siren, Piezo and
Strobe outputs for additional hardwired noisemakers.
The R8 has a number of sophisticated power saving features designed to provide at least 48
hours service running on the backup battery alone. (This includes one full alarm condition with
sirens, strobe and dialler).
The built-in dialler uses Contact ID format for central station monitoring as well as audible monitoring
to any telephone. The user can also dial into the system for remote arming and disarming over
the telephone line.
INTRODUCTION
SPECIFICATIONS
Radio zones ............................... 8
Max. Radio Keys ........................ 14
Hardwired zones ......................... 1
Hardwired tamper zones ............. 1
Radio compatibility ..................... Ness supervised & encrypted radio devices
Dialler format .............................. Contact ID & Audible Pulse
On board Keypad ........................ Backlit, programming & user functions
LCD display ................................ High contrast icon display
Plug pack ................................... 240V AC, output 17V AC @300mA
Quiescent current draw ............... 10 mA (in power save mode if mains is off)
Built-in backup battery ................ 12 volt 0.8 Amp/hour, sealed lead acid
Dynamic Battery Test .................. Every Hour and on arming/disarming
Fuses ......................................... 2A resettable / sirens
2A resettable / Reset output, built-in piezo and strobe
Siren output ................................ 1 x 8 Ohm horn speaker
On board piezo siren ................... 110 dB
Piezo output ............................... 12V DC 300mA max.
Strobe output .............................. 12V DC
Dimensions ................................ 210(w) x 145(h) x 40(d) mm

Ness R8 - Installation and Programming Manual 5
COMPATIBILITY
The Ness R8 supports all Ness radio devices as shown below. All late model Ness transmitters
send encrypted transmissions to prevent eavesdropping and substitution. Ness fixed transmitters
can send a regular supervision signal which the R8 monitors to ensure system security.

Ness R8 - Installation and Programming Manual
6
INSTALLATION
INSTALLATION PROCEDURE
The location of the main panel housing should be in an area
that is within the protected area of the premises. A linen closet
or cupboard are good examples as these are generally located
in the centre of the Premises.
1. Remove the front housing by first removing the bottom
locking screw, (screw is not fitted for shipping), then
unclip the bottom of the front housing and lift upwards.
2. Disconnect the 12 way wire loom from the main board
on the front housing.
3. Unclip and remove the terminal board from the back
housing and remove the battery. (The battery lead
connects to the main board on the front housing. It is
not plugged in for shipping). The terminal board and
battery must be removed to reveal all four mounting
holes in the back housing.
3. Mount the back housing to the wall using the 4 slotted
mounting holes.
4. Replace the Terminal Board in the back housing and
reconnect the 12 way wire loom to the main board.
5. Connect the plug pack wiring to the Terminal Board,
(making sure that mains power is not turned on at this
stage). Connect siren wires and external tamper inputs
as required.
6. Replace the battery.
POWER UP PROCEDURE
The power up procedure assumes that installation of the R8
is completed and the plug pack is wired.
7. Connect the battery lead to the BATTERY socket on the
main board.
8. Turn on the plug pack.
Note 1: When power is applied, the R8 will enter Disarmed
mode, unless it was in Armed or Monitor mode when
previously running, in which case it will resume in the previous
mode - UNLESS the box tamper or external tamper inputs are
unsealed. (See note 2).
Note 2: To enter Installer Program Mode on initial power up,
apply power with the internal tamper open, (lid open), or the
external tamper open.
Note 3: The BATTERY icon will flash if the initial battery voltage
is low and will turn off when the battery has reached full charge.
REMOVING THE
FRONT HOUSING
100-690 R8
PACKING LIST
1 R8 Control panel
1 Plug pack 17VAC
300mA
1 Battery 12V 0.8Ah
1 Telephone lead
1 External antenna
1 User manual
1 Installer manual
1 Zone list label
3 2K2 resistors

Ness R8 - Installation and Programming Manual 7
INSTALLATION
FRONT
HOUSING
(rear)
Bottom
CONNECTING
LEAD
EXTERNAL
ANTENNA
MOUNTING
SCREW
CABLE ENTRY VIA CAVITY WALL
BACK HOUSING
CABLE TIE CABLE TIE
CABLE TIE
CONDUIT
TERMINAL BOARD
CABLE TIE
CABLE TIE
BACK HOUSING
CABLE ENTRY VIA CONDUIT
EXTERNAL ANTENNA
The external antenna,
(supplied), can be fitted if
required.
The sensitivity of the R8 radio
receiver with or without the
external antenna is subject to
RF conditions specific to the
site.
Tests have shown that most
sites will perform well using the
standard internal antenna.
The external antenna can be
fitted at the installer's discretion
in cases where its reception
pattern may better suit the
local radio environment.

Ness R8 - Installation and Programming Manual
8
CONNECTION DIAGRAM
MOUNTING HOLES
Slotted x 4
CABLE ENTRY
BACK HOUSING
FRONT
HOUSING
(rear)
WIRING
BATTERY
12V 0.8AH BATTERY
TERMINAL
BOARD
Telephone Lead
Bottom
Battery
MAIN
BOARD
INTERNAL TAMPER
SWITCH
EARTH AC
TAMP
STR+
PIEZ+
0V ZONE
+
PIEZ
STR
SIREN
SIREN
PIEZ+
STR+
EARTH
PIEZ-
STR-
0V
TAMP
0V
Z1
-
+
AC17V
TERMINAL BOARD
EARTH AC
TAMP
STR+
PIEZ+
0V ZONE
+
PIEZ
STR
SIREN
17V AC
Earth
EXTERNAL HORN SPEAKER (NOI-110) Max. Qty 1.
STROBE LIGHT (NOI-300) Max. Qty 1.
HARDWIRED ZONE, 2K2 END OF LINE
EXTERNAL SCREAMER (100-172) Max. Qty 1.
PLUG PACK 17VAC 300mA (Supplied).
2K2
N.O TAMPER SWITCH (761-002)
Colour: BLACK (Supplied with Ness siren covers).
N.O.
N.C.

Ness R8 - Installation and Programming Manual 9
INPUTS / OUTPUTS
INPUTS
ZONE
Zone input for optional hardwired detection devices. Operates in
series with any radio devices on zone 8. The input must be
terminated with a 2K2 (2200 ohm) end of line (EOL) resistor even if
unused.
TAMP
24hr input for connection of external tamper switches. This input
operates in series with the internal tamper switch.
The input must be terminated with a 2K2 (2200 ohm) end of line
(EOL) resistor even if unused.
AC / EARTH
AC power input and earth connection. Use the supplied 17V AC
300mA plug pack.
OUTPUTS
SIREN
Timed siren output for connection of maximum one (1) 8 Ohm horn
speaker.
STR
Output for connection of 1 x NOI-300 Ness strobe light. As a power
saving feature, the strobe output times out after 11 hours. If mains
power is off, the output will time out after 1 hour.
PIEZ
Timed output for connection of maximum 1 x 12V screamer, (Ness
Part No. NOI240, NOI 230, 100-238 or 100-172).
ONBOARD SIREN (BUILT-IN)
The onboard piezo siren is an integral part of the R8 electronics. It
is used for keypad beeps, doorbell chime, arm/disarm chirps and
internal siren on alarm. The internal Siren can be disabled by
program option P60E 8E. When the Internal Siren function is
disabled, the onboard siren still outputs keypad beeps and other
audible features.

Ness R8 - Installation and Programming Manual
10
R8 KEYPAD
AUDIBLE & VISUAL FEEDBACK
The R8 onboard keypad provides the facility for user level and installer level programming and all
user operation and emergency functions. The keys are soft-touch silicon rubber and are backlit
for high visibility. Any keypress will turn on the backlighting for 4 minutes.
2
5
8
0
1
4
7
P
3
6
9
E
ARM
MONITOR
EXCLUDE
MEMORY
PROGRAMFUNCTION BUTTONSONBOARD SIREN
/ BEEPER
FIRE
MEDICAL
PANIC
BACKLIT
LCD DISPLAY
ENTER
OUTPUT TYPEOUTPUT DESCRIPTION
Keypad Acknowledge key press
Keypad Valid entry, end of Exit Time
Keypad Invalid entry
Low battery / AC Fail / Medical Alarm
Alarm, Entry Delay, etc
Arm
Disarm
The Doorbell has been pressed.
Alarm condition
Panel Armed or Disarmed
Alarm condition
Keypad beeper
Onboard Siren
External Siren output
Onboard Siren
Piezo output
External Siren output
Strobe output
Onboard Siren
External Siren output
Onboard Siren
SHORT BEEP
3 BEEPS (RAPID)
LONG BEEP
8 BEEPS (RAPID)
CONTINUOUS BEEPS
1 CHIRP*
3 CHIRPS*
DOORBELL TONES
SIREN CONTINUOUS
STROBE BURST
STROBE CONTINUOUS
SIREN BURST,
(Low Volume)
Zone Auto Exclude warning
* Arm/disarm chirps must be enabled.
Andere Handbücher für R8
1
Inhaltsverzeichnis
Andere Ness Bedienfeld Handbücher

Ness
Ness D-8 Bedienungsanleitung

Ness
Ness 5000 Series Bedienungsanleitung

Ness
Ness D-8 Bedienungsanleitung

Ness
Ness D8X Bedienungsanleitung

Ness
Ness D8X Bedienungsanleitung

Ness
Ness D16 Bedienungsanleitung

Ness
Ness D8XCEL Benutzerhandbuch

Ness
Ness D-8 Montageanleitung

Ness
Ness M1 Navigator Bedienungsanleitung

Ness
Ness ECO8x Bedienungsanleitung

Ness
Ness R8 Bedienungsanleitung

Ness
Ness D-8 Montageanleitung

Ness
Ness D16x C-Bus Enabled Montageanleitung

Ness
Ness D16 Montageanleitung

Ness
Ness D-8 Bedienungsanleitung

Ness
Ness D24 Montageanleitung

Ness
Ness D8X Montageanleitung

Ness
Ness D24 Bedienungsanleitung

Ness
Ness R16 Bedienungsanleitung

Ness
Ness pro-lx Bedienungsanleitung