network D-422-MG Bedienungsanleitung

D-422-MG
RS-422 Multiplexer with GPI I/O
User Manual
Rev. 0

Network Electronics ASA
Thorøya
Sandefjord, Norway
Phone: +47 33 48 99 99
Fax: +47 33 48 99 98
e-mail: [email protected]
www.network-electronics.com
Direct Service Phone: +47 90 60 99 99
Revision history
The latest version is always available in pdf-format on our web-site:
http://www.network-electronics.com/
Current revision of this document is the uppermost in the table below.
Revision Replaces Date Sign Change Description
0 C 2006-05-11 OEH
GPI monitoring and control via GYDA
Added RS422 VTR master and slave pinouts
C B 2004.06.08 OEH Added CWDM channels 9-16.
B A 2004.05.28 OEH Added power/latency specification.
A Preliminary version. Pre production run.

Index
REVISION HISTORY ..........................................................................................................2
1GENERAL ...................................................................................................................4
2SPECIFICATIONS .......................................................................................................6
2.1 Electrical .............................................................................................................6
2.2 Inputs..................................................................................................................6
2.2.1 RS-422 .............................................................................................................6
2.2.2 GPI...................................................................................................................6
2.2.3 Optical input...................................................................................................6
2.3 Outputs...............................................................................................................6
2.3.1 RS-422 .............................................................................................................6
2.3.2 GPI...................................................................................................................7
2.3.3 Optical output ................................................................................................7
3CONNECTOR MODULE .............................................................................................8
3.1 D-422-MG-C1 .....................................................................................................8
3.2 Mounting the connector modules ....................................................................8
3.3 RS-422 Connector Pin Assignments ..................................................................9
3.4 GPI Input Connector Pin Assignments..............................................................9
3.5 GPI Output Connector Pin Assignments.........................................................10
4OPERATIONAL STATUS MONITORING ..................................................................11
4.1 GYDA – Monitoring and control .....................................................................11
4.2 Front Panel - Status Monitoring......................................................................11
5OPERATIONAL STATUS MONITORING ..................................................................13
DECLARATION OF CONFORMITY WITH CE ..................................................................14

D-422-MG Rev. 0
4
1General
Figure 1 D-422-MG Block diagram
The flashlink D-422-MG module provides an economical solution for transmitting RS-422
and GPI data signals via fiber optic cable. A pair of D-422-MG allows bi-directional
transmission of up to 8 RS-422 and 16 GPI data lines for distances over 60km. When
access to fiber is limited, D-422-MG can be combined with the flashlink optical
multiplexing WDM, CWDM or DWDM products.
The D-422-MG module multiplexes up to 8 RS-422 and 16 GPI inputs into an outgoing
datastream while at the same time demultiplexing an incoming datastream into 8 RS-422
and 16 GPI outputs. The outgoing multiplexed stream is available both as an optical
signal and as an electrical signal for use with a flashlink multichannel DWDM system.
As stand alone unit, the D-422-MG module utilises 2 fiber strands for bi-directional data
transport. Using either 2 fiber strands or optical multiplexing technology guarantees
minimum possible latency for applications where timing is crucial. The D-422-MG module
is supplied together with the D-422-MG-C1 connector module. The optical output is
made with a Fabry-Perot laser diode for 1310±40nm or a DFB laser for 1550±40nm and
the CWDM wavelengths according to ITU-T G.694 from 1470±6nm up to 1610±6nm.
The product is available in 19 versions:
D-422-MG-13T -7.5dBm 1310±40nm -7.5 dBm F-P laser
D-422-MG-13T 0 dBm 1310±40nm 0 dBm F-P laser
D-422-MG-15T 0 dBm 1550±40nm 0 dBm DFB laser

D-422-MG Rev. 0
5
CWDM
D-422-MG-C1470 1470±6nm 0dBm DFB laser
D-422-MG-C1490 1490±6nm 0dBm DFB laser
D-422-MG-C1510 1510±6nm 0dBm DFB laser
D-422-MG-C1530 1530±6nm 0dBm DFB laser
D-422-MG-C1550 1550±6nm 0dBm DFB laser
D-422-MG-C1570 1570±6nm 0dBm DFB laser
D-422-MG-C1590 1590±6nm 0dBm DFB laser
D-422-MG-C1610 1610±6nm 0dBm DFB laser
D-422-MG-C1270 1270±6nm 0dBm DFB laser
D-422-MG-C1290 1290±6nm 0dBm DFB laser
D-422-MG-C1310 1310±6nm 0dBm DFB laser
D-422-MG-C1330 1330±6nm 0dBm DFB laser
D-422-MG-C1350 1350±6nm 0dBm DFB laser
D-422-MG-C1370 1370±6nm 0dBm DFB laser
D-422-MG-C1390 1390±6nm 0dBm DFB laser
D-422-MG-C1410 1410±6nm 0dBm DFB laser

D-422-MG Rev. 0
6
2Specifications
2.1 Electrical
Power: +5V DC 0.8A 4W,
Control: Gyda system controller.
Monitoring: Front panel LEDs and Gyda system controller
RS-422 Latency: 500ns maximum single direction latency including
1m of fiber.
Additional latency 5µs/km of fiber.
GPI Latency: 5µs maximum single direction latency including
1m of fiber.
Additional latency 5µs/km of fiber.
2.2 Inputs
2.2.1 RS-422
Signal format: RS-422
Connector: RJ-45
Bit Rate: DC up to 115.2 kbps
2.2.2 GPI
Connector: DSUB 25
Signal type: Internal pull up to 5V
2.2.3 Optical input
Sensitivity: better than –30dBm
Max. input power: -3dBm
Optical wavelengths: 1310nm, 1550nm
Transmission circuit fiber: Multi Mode 50/125um, Single Mode 9/125um
compatible
Return loss: > 26dB
Connector: SC/UPC, Return Loss better than 40dB
2.3 Outputs
2.3.1 RS-422
Signal format: RS-422
Connector: RJ-45
Bit Rate: DC up to 115.2 kbps

D-422-MG Rev. 0
7
2.3.2 GPI
Connector: DSUB-25
Signal type: Open collector transistor.
Maximum voltage: 30 V
Maximum current: 100 mA
2.3.3 Optical output
Transmission circuit fibre: Single Mode
Light source: F-P/DFB Laser
Optical wavelength (ver. 13T): 1310nm ±40nm
Optical power: -7.5 dBm
Optical power (option): 0 dBm
Optical wavelength (ver. 15T): 1550nm ±40nm
Optical power: 0 dBm
Optical wavelength (ver. C1nn0): 1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410,
1470, 1490, 1510, 1530, 1550, 1570, 1590,
1610nm ±6nm as per ITU-T G.694.2
Optical power: 0 dBm
Jitter (UI=unit interval): Max. 0.135 UI
Return loss: Typ. > 40 dB
Maximum reflected power: 4%
Connector: SC/UPC

D-422-MG Rev. 0
8
3Connector module
3.1 D-422-MG-C1
Figure 2 D-422-MG-C1 Connector module.
The D-422-MG has a dedicated connector module: D-422-MG-C1. This module is
mounted at the rear of the sub-rack. The module is shown in figure 2. Note that this
connector module always occupies two (2) slots in the sub-rack.
To set up a link, two D-422 modules must be used. The RS-422 data cable is connected to
RS-422/E1 on each of the D-422 modules. The two modules are connected to the fibres
with one fiber from TX on module 1 to RX on module 2, and from RX on module 1 to TX
on module 2. The TX UPG connector contains an electrical version of the modulated
signal running on the fiber. This connector is used for future upgrade with a flashlink
multichannel DWDM system.
3.2 Mounting the connector modules
The details of how the connector modules are mounted, can be found in the user manual
for the sub-rack frame: FR-2RU-10-2.
This manual is available from our web site: http://www.network-electronics.com/

D-422-MG Rev. 0
9
3.3 RS-422 Connector Pin Assignments
RS-422 shall be connected to one of the RS-422 connectors, positioned as shown in figure
2. The connectors are RJ-45 style, 8-pin modular jacks. Each connector has two RS-422
ports, referred to as ports 1 and 2 in the below table. In the event that only one port is in
use, an RJ-11 style 4/6 (4-wire, 6-position) jack can be used instead. Signals marked as
inputs on the D-422-MG shall be connected to the outputs of the connected devices, and
vice versa. The columns for DB9 VTR Master and Slave show which pin on the 9 pin DSUB
should be connected to the signal. Note that when connecting an active device instead of
a straight-through cable between a VTR master and slave (device and controller), one end
of the active device must use a crossed cable. The table below takes the crossing on the
slave side into consideration.
RS-422 pin layout:
Signal Name Port1 Port2 DB9 VTR
Master
DB9 VTR
Slave
Mode
RX + Receive Pos. Pin 3 Pin 1 Pin 3 Pin 7 Input
RX - Receive Neg. Pin 6 Pin 2 Pin 8 Pin 2 Input
TX + Transmit Pos. Pin 5 Pin 7 Pin 7 Pin 3 Output
TX - Transmit Neg. Pin 4 Pin 8 Pin 2 Pin 8 Output
Figure 3 RS-422 outlet
3.4 GPI Input Connector Pin Assignments
GPI inputs shall be connected to the DB25 connector marked “GPI
IN”. The pinout is the same as for the VikinX GPI panels, see table.
All inputs are internally connected to +5V via a pull-up resistor. The
inputs will be activated when pulling them to Ground.
Ground is available on the following pins: 2, 5, 8, 11, 13, 16, 19, 22,
25 and on the connector chassis.
Input Pin
1 12
2 24
3 23
4 10
5 9
6 21
7 20
8 7
9 6
10 18
11 17
12 4
13 3
14 15
15 14
16 1

D-422-MG Rev. 0
10
3.5 GPI Output Connector Pin Assignments
GPI outputs shall be connected to the DB25 connector marked
“GPI OUT”. The pinout is the same as for the VikinX GPI panels,
see table.
The GPI outputs are of open collector type. An output can
switch a maximum load of 100mA at 30V.
Any device to be controlled by the GPI outputs (lamp, LED or
similar) needs to be connected to an external supply voltage on
one end and to the GPI output on the other end.
Ground is available on the following pins: 2, 5, 8, 11, 13, 16,
19, 22, 25 and on the connector chassis.
Output Pin
1 12
2 24
3 23
4 10
5 9
6 21
7 20
8 7
9 6
10 18
11 17
12 4
13 3
14 15
15 14
16 1
Inhaltsverzeichnis
Beliebte Multiplexer Handbücher anderer Marken

ADTRAN
ADTRAN Frameport 768 Bedienungsanleitung

Elo TouchSystems
Elo TouchSystems E247 Bedienungsanleitung

Paradyne
Paradyne Hotwire 8786 Bedienungsanleitung

RFL Electronics
RFL Electronics 9508D UCC Bedienungsanleitung

Miranda
Miranda AMX-101i Bedienungsanleitung

ShipModul
ShipModul MiniPlex-AIX NMEA-0183 Bedienungsanleitung