GB
5
General
This manual contains instructions about how Contura 51L must be
assembled and installed.
To guarantee the function and safety of the stove we recommend
that it is installed by a professional. Our Contura agents can
recommend a suitable installer.
The stove is type approved and must be connected to a chimney
dimensioned for at least 350°C, The connector on the stove
is suitable for pipes with an inner diameter of Ø150 mm and
an outer diameter of maximum Ø154 mm. The room or space
containing a stove shall have a permanent air supply sufficent to
ensure proper combustion, to determine correct amount of air
supply use current edition of Building Regulations.
Eldstadsbeklädnad
Löstagbart handtag
Rosterreglage
Asklåda
Förbränningsluftsreglage
Brasbegränsare
Typskylt
Fire-box surround
Grate shuttle
Ash-pan
Log guard
Removable handle
940
150
840
175 175
370
HANDÖL
Inaccordance with standards below
markingwas affixed:
EuropeanStandard:
SEQuality Certification, P-marked:
NOStandard NS 3059:
DEand A Standard DINplus
andArt 15a B-VG:
Type:
NominalOutput:
Fuel:
Minimundraught:
Fluegas temerature:
Energyefficiency:
Emissionof CO in cumbustion products:
Distanceto cumbustible wall (mm):
Productionnumber:
Followthe installation instructions.
Useonly recomended fuels
NIBEAB Box 134 SE-285 23 MARKARYD SWEDEN
2006
EN13240
Certno 220316
SINTEF110-0257
RRF-4007 1261
H51/H52/H52T
5kW
Wood
12Pa
275°C
79%
0,13%
Behind150
Beside500
Corner150
HANDÖL
NIBE AB SE-85 21 Markaryd Sweden
Type:
Production no.
50-series
7090300236
Type plate
Air supply control
GENERAL
Building application
Before installing a stove
or erecting a chimney it is
necessary for you to apply
for planning permission
from your local authority.
Ask your local authority
for advice regarding
building regulations and the
application.
Hearth dimensions
The stove must be placed on a constructional heart with the
minimum dimensions shown beside, installations distances
must also be according to diagrams on next page. Check that
the building has enough bearing capacity for the heart, stove
and chimney. The stove can be loaded with maximum 100 kg of
chimney.
Chimney
Note! The stove installation and connection to a chimney must
be accomplished with the current edition of Building Regulations.
We recommend that you consult a local chimney sweep before the
installation to make sure that the chimney is in good condition.
The stove requires a draught in the chimney of at least –12
Pa. The draught is affected both by the length and area of the
chimney, and by how well sealed it is. The recommended minimum
flue length is 3.5 m and its diameter should be Ø130 to Ø150 mm.
Carefully check that the chimney is sealed and that there is no
leakage around soot hatches and flue connections.
Note that a flue with sharp bends and horizontal routing reduces
the draught in the chimney. Maximum horizontal flue is 1 m,
on the condition that the vertical flue length is at least 5 m. It
must be possible to sweep the full length of the flue and the soot
hatches must be easily accessible.
Technical data
Output 4 kW
Nominal output 5 kW
Efficiency level 79%
Flue gas mass flow 6,0 g/s
Model C51L
Weight (kg) 124
Width (mm) 495
Depth (mm) 420
Height (mm) 630
The connector’s inner diameter is Ø154 mm
Type approved in accordance with:
European standard EN-13240
Swedish environmental and quality marking,
Swan marked No 378 001 and
P-marking cert. no. 22 03 16
(N) NS 3059, Cert.nr SINTEF 110-0257
(DE/A) DINplus, Art. 15a B-VG RRF-40 07 1261
DEFRA exempted
The stove can be used in Smoke Control Areas. Smouldering, i.e.
reduced air supply, are prevented by blocking the combustion
damper of 4 kW output.