GB
84 FACTS
Effect 3-9 kW
Nominal effect 6 kW
Efficiency 79%
Model C26K High
Weight (kg) 240*
Width (mm) 580
Depth (mm) 462
Height (mm) 1622
*Weight, C26K with heat reservoir
(option) (kg) 360
*Weight, C26K with oven
(option) (kg) 265
Type approved in accordance with:
European standard EN 13240
Swedish environmental and quality marking,
P-marking cert. no. 220312
Norwegian standard NS 3059, SINTEF 110-0223
German standard DIN EN/ 13240 RRF 40 08 1853
Installation by authorised
technician
This manual contains instructions on
how the stoves must be assembled and
installed. To ensure the function and
safety of the stove, we recommend that
the installation be carried out by an
authorised technician. Contact one of
our dealers who can recommend suitable
fitters.
Building permission
These main instructions may give guidance
which would contravene national building
regulations. Please refer to supplementary
instructions or ask your local authority for
advice regarding building regulations.
Before installing a stove or erecting a
chimney it is necessary for you to make
a building application permission to your
local authority.
Structural support
Check that the wood joists are strong
enough to bear the weight of the stove
and chimney. The stove and chimney can
usually be placed on a normal wooden joist
in a single occupancy house, if the total
weight does not exceed 400 kg.
Hearth plate
Due to the risk of embers falling out, a
flammable floor must be protected by a
hearth plate. It must extend 300 mm in
front of the stove and 100 mm on each
side of the stove, or have a 200 mm
extension on each side of the opening.
The hearth plate can consist of natural
stone, concrete, metal plate or glass. A
painted metal or glass hearth plate is
available as an accessory for these models.
Important to remember!Technical details
Name of tile
403882
403881
403880
403877
403878
403879
403932
403931
403930
403929
403928
Eldstadsbeklädnad
Rosterreglage Asklåda
Förbränningsluftsreglage
Brasbegränsare
HANDÖL
Inaccordance with standards below
markingwas affixed:
EuropeanStandard:
SEQuality Certification, P-marked:
NOStandard NS 3059:
DEand AT Standard DIN 18.891 and
Art15a B-VG:
Type:
NominalOutput:
Fuel:
Minimundraught:
Fluegas temerature:
Energyefficiency:
Emissionof CO in cumbustion products:
Distanceto cumbustible wall (mm):
Followthe user’s instructions and use only recomended fuel
NIBEAB Box 134 SE-285 23 MARKARYD SWEDEN
2007
EN13240
Certno 0112/07
SINTEF110-0275
RRF-4007 13 90
Handöl31/31A/32/32A
5kW
Wood
12Pa
280°C
78%
0,14%
Behind150
Beside450
Corner150
HANDÖL
NIBE AB SE-85 21 Markaryd Sweden
Type:
Production no.
50-series
7090300236
Type plate
Log guard
Ash-pan
Grate shuttle
Air supply control
Fire-box surround