nvent SCHROFF CPCI PSB System Subrack 10 U Bedienungsanleitung

CPCI PSB System Subrack 10 U
User Manual
Product Number:
24579-028
Revision: R1.1, October 30, 2009
Doc-No: 63972-163

Impressum:
Schroff GmbH
D-75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright © 2007
All rights and technical modifications reserved.
Rev. Date updated Change
R1.0 November 21, 2007 Initial release
R1.1 October 30, 2009 Second CMM slot removed

CPCI System Subrack 10 U
24579-028
www.schroff.biz I R1.1, October 30, 2009
Table of Contents
1 Safety................................................................................................................. 1
1.1 Intended Application............................................................................................ 1
1.2 Safety Instructions ............................................................................................... 2
1.3 Safety Symbols used in this document................................................................ 2
1.4 General Safety Precautions................................................................................. 2
1.5 References and Architecture Specifications........................................................ 3
2 Product Definition............................................................................................. 4
2.1 Mechanical Overview........................................................................................... 5
2.2 Subrack................................................................................................................ 5
2.3 CPCI PSB Backplane .......................................................................................... 6
2.4 Power Supply....................................................................................................... 7
2.4.1 Grounding.............................................................................................. 8
2.4.2 Power Supply......................................................................................... 9
2.5 Thermals............................................................................................................ 11
2.6 Fan Control Module (FCM)................................................................................ 12
2.7 Chassis Monitoring Module (CMM) -optional- ................................................... 13
3 Installation....................................................................................................... 14
3.1 Unpacking.......................................................................................................... 14
3.1.1 Ensuring Proper Airflow....................................................................... 14
3.2 Rack-Mounting................................................................................................... 15
3.3 Initial Operation.................................................................................................. 16
4 Service............................................................................................................. 17
4.1 Technical support and Return for Service Assistance....................................... 17
4.2 Declaration of Conformity .................................................................................. 17
4.3 Scope of delivery............................................................................................... 18
4.4 Accessories ....................................................................................................... 18
4.5 Spare Parts........................................................................................................ 18
5 Technical Data ................................................................................................ 19

CPCI System Subrack 10 U
24579-028
www.schroff.biz II R1.1, October 30, 2009

CPCI System Subrack 10 U Safety
24579-028
www.schroff.biz 1 R1.1, October 30, 2009
1 Safety
1.1 Intended Application
The CompactPCI (CPCI) system subrack, described in this manual, is intended
as a platform for a microcomputer system based on the CompactPCI Standard
PICMG 2.0 Rev.3 and PICMG 2.16.
The CPCI system subracks are designed for protection class IP 20 and can be
used only in the resp. environments.
For higher protection requirements, a.e. IP 54/55 you must install the system
subrack in a protective case.
CPCI system subracks are not end-products, so there is no valid approval for
this unit. In order to enable stand-alone functionality, additional elements are
required. An operational system is achieved only by way of appropriate CPCI
boards.
The completion and final testing of the units have been carried out, or at least
supervised, by qualified technicians. These instructions are directed exclusively
to these qualified technicians i.e.engineers, trained and qualified electricians
etc.
Make sure that:
• the assembled unit complies with the safety regulations currently applicable
in the country it is going to be used.
• the overall unit complies with all other regulations and specifications at the
place and country of use, e.g. interference limits, approval by the telecom-
munications authorities.

CPCI System Subrack 10 U Safety
24579-028
www.schroff.biz 2 R1.1, October 30, 2009
1.2 Safety Instructions
The intended audience of this User’s Manual is system integrators and
hardware/software engineers.
1.3 Safety Symbols used in this document
1.4 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and
connection practices for installing this equipment in a telecommunication
environment.
• Install this equipment only in compliance with local and national electrical
codes.
Hazardous voltage!
This is the electrical hazard symbol. It indicates that there are dangerous
voltages inside the Shelf.
Caution!
This is the user caution symbol. It indicates a condition where damage of the
equipment or injury of the service personnel could occur. To reduce the risk of
damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
TheShelfcontainsstaticsensitivedevices.Topreventstaticdamageyoumust
wear an ESD wrist strap.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This equipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

CPCI System Subrack 10 U Safety
24579-028
www.schroff.biz 3 R1.1, October 30, 2009
1.5 References and Architecture Specifications
• User Manual CPCI Backplane 23006-610
Order no.: 73972-089
• User Manual CPCI Backplanes
Order no.: 73972-101
• User Manual Fan Control Module (FCM)
Order no.: 73972-083
• User Manual Power Supply
Order no.: 73972-077
• User Manual Chassis Monitoring Module (CMM)
Order no.: 73972-084
For more information see the catalogue „Electronic Packaging“ and at
www.schroff.biz

CPCI System Subrack 10 U Product Definition
24579-028
www.schroff.biz 4 R1.1, October 30, 2009
2 Product Definition
The Schroff CPCI system subrack consists of:
• A shielded 19“ subrack with front assembly area for
6 U front boards according to CompactPCI Standard PICMG 2.0 Rev.3 and
PICMG 2.16
• A 6 U CPCI PSP Backplane (PICMG 2.16)
2/14 slot (2 Fabric (Switch) and 14 Node Slots)
• Two 19“ plug-in power supply with wide range input
• Speed controlled fans for cooling the boards
• Fan Control Module (FCM) for fan monitoring/controlling
• Display module
• Mains/line switch
• Rear assembly area for 6 U, 4 HP Rear I/O Modules

CPCI System Subrack 10 U Product Definition
24579-028
www.schroff.biz 5 R1.1, October 30, 2009
2.1 Mechanical Overview
Figure 1: Mechanical Overview
2.2 Subrack
The 10 U 19“ system based on the Schroff europacPro System with EMC
shielding. The front card cage provides space for the installation of 14 CPCI
(Node) boards and 2 Switch boards.
The lower guide rails are fitted with ESD clips.
10006813
1 DC Switch 6 Power Supply #2
2 Power Supply #1 7 Chassis Monitoring Module (CMM)
(optional)
3 Front card cage with guide rails 8 Power Supply #4 (optional)
4 Power Supply #3 (optional) 9 Front panel 3 U / 1 HP
5 Drawer with Fans 10 Bottom-hinged front panel,
perforated

CPCI System Subrack 10 U Product Definition
24579-028
www.schroff.biz 6 R1.1, October 30, 2009
2.3 CPCI PSB Backplane
Figure 2: Backplane
The 6 U Backplane provides:
• 2 Fabric Slots placed left to the Node Slots including optional Link between
both
• 14 Node Slots
• 1 slot for a Chassis Monitoring Module (CMM)
• 4 PSU Slots acc. to PICMG 2.11 for 4 x 3 U PSUs
• CompactPCI bus (PICMG2.0 R.3.0) is implemented at Node Slots;
two independent segments with System Slot left and right
Applicable Specifications:
PICMG 2.16 R1.0 Packed Switched Backplane
PICMG 2.0 R3.0 CPCI Core Specification
PICMG 2.01 R2.0 Hot Swap
PICMG 2.09 R1.0 System Management Bus
PICMG 2.10 R1.0 Keying
PICMG 2.11 R1.0 Power Interface Specification
For more information see the Backplane’s User Manual, Order No.: 73972-089/
-101, in the catalogue and at www.schroff.biz
12307811
Inhaltsverzeichnis
Andere nvent Netzwerk-Hardware Handbücher
Beliebte Netzwerk-Hardware Handbücher anderer Marken

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Bedienungsanleitung

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Bedienungsanleitung

Yudor
Yudor YDS-16 Bedienungsanleitung

D-Link
D-Link ShareCenter DNS-320L Bedienungsanleitung

Samsung
Samsung ES1642dc Gebrauchsanweisung

Honeywell Home
Honeywell Home LTEM-PV Montageanleitung