Observer TSTAT0201CW Bedienungsanleitung

616 01 1019 00 10/17/14
Communicating Wall Control
With Wi--FiRCapability
Installation Manual
TSTAT0201CW
U.S. Patent No. 7,243,004
U.S. Patent No. 7,775,452
COMMUNICATING SYSTEM
R
All trademarks are the property of the respective owners.
Wi-Fi®is a registered trademark of the Wi-Fi Alliance Corporation.

261601101900
Safety Considerations 6...............................
Introduction 7.........................................
Quick Start 9.........................................
Set Day and Time 9.................................
Set Schedule for All Days 11.........................
Installation 14........................................
Overview 14.......................................
Check Equipment 15................................
Location 15........................................
Wall Control 15..................................
Remote Room Sensors 16........................
Wiring Considerations 17............................
Shielded Wire 19.................................
Non-communicating equipment 19.................
Mounting 19.......................................
Humidifier Connection 21............................
Bypass Humidifiers 21............................
Fan Powered Humidifiers 21.......................
Commissioning 22....................................
Communicating System Overview 22..................
Selecting Accessories 24............................
Selecting Indoor Unit 24.............................
Equipment Summary 26.............................
Brand Selection 26.................................
Current Software Version 27.........................
Software Updates 27................................
Setting Up Remote Access and Wi-Fi® Connection 28..

3
616 01 1019 00
Install/Service Menus – Communicating and
Non-Communicating Mode 30..........................
Equipment Summary Menu 31.......................
Service Menus 32..................................
Status 32........................................
Heat Stage (Furnace) 32........................
Electric Heat (Fan Coil) 32......................
Airflow CFM 32................................
Inducer RPM (Modulating furnaces only) 32.......
Blower RPM (Modulating furnaces only) 33........
Lockout Timer 33..............................
Heat Pump/AC Status 33.......................
Stage: (Heat/Cool) 33..........................
Defrost 33....................................
Outdoor Coil Temp 33..........................
Last 10 System Faults 33.........................
Lifetime Run History 34...........................
Cycle Counters 34................................
Run Timers 34...................................
Filter Reminder 26................................
Auto Mode Enable 36...............................
Room Temperature Sensing 37......................
Reversing Valve 38.................................
English/Metric Display 39............................
FanonwithW 40...................................
Cooling Lockout 41.................................
Auxiliary Heat Lockout 42............................
Heat Pump Lockout 43..............................

461601101900
Minimum Cooling Setpoint 44........................
Maximum Heating Setpoint 45........................
Outdoor Air Temperature Offset 46...................
Room Air Temperature Offset 47.....................
Smart Recovery 48.................................
Setpoint Deadband 49..............................
Cycles Per Hour 50.................................
Auto Changeover Timer 51..........................
Time Between Fuel Types 52........................
Humidity Offset 53..................................
Programming On/Off 54.............................
Reset to Factory Defaults 55.........................
Dealer Info 56......................................
Service Reminder 57................................
Install/Service Menus - Communicating Equipment 57.....
Setup Menu 57.....................................
English/Metric Display 58.......................
Airflow 59.......................................
Heating Airflow 59.............................
Furnace / Fancoil Heating Airflow 59.............
Heat Pump Heating Airflow 60...................
Cooling Airflow 60.............................
Dehum Airflow 60..............................
Furnace Airflow (Capacity) Limiting 61............
Dehum Drain 61...............................
Off Delay 61..................................
Low Heat Rise 62..............................
Defrost Interval 63.............................

5
616 01 1019 00
Defrost With Furnace 64........................
Quiet Shift 64.................................
Zones 65.....................................
Zone Weighting 66.............................
Zone Airflow Control 67.........................
Bypass 68....................................
Airflow Capacity 68............................
Damper Type 69...............................
Leaving Air Sensor (LAS) 70.......................
Disable Zoning 70................................
Damper Timing 71................................
HRV - Heat Recovery Maintenance 71..............
Daughter Board 72...............................
Operational Information 73........................
Auto Mode 73....................................
Setpoint Deadband 73..........................
Offsets 73....................................
Cycles Per Hour 73............................
Programming 74.................................
Smart Recovery 74...............................
Appendix – Wiring Diagrams 75.........................

661601101900
Safety Considerations
Improper installation, adjustment, alteration, service, main-
tenance, or use can cause explosion, fire, electrical shock, or
other conditions which may cause death, personal injury or
property damage. Consult a qualified installer, service
agency or your distributor or branch for information or assist-
ance. The qualified installer or agency must use factory-au-
thorized kits or accessories when modifying this product.
Refer to the individual instructions packaged with the kits or
accessories when installing.
Follow all safety codes. Wear safety glasses, protective
clothing, and work gloves. Have a fire extinguisher available.
Read these instructions thoroughly and follow all warnings
and cautions included in literature and attached to the unit.
Consult local building codes and the current edition of the
National Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Elec-
trical Code CSA C22.1.
Recognize safety information. When you see this symbol
on the unit and in instructions or manuals, be alert to the
potential for personal injury. Understand these signal words:
DANGER, WARNING, and CAUTION. These words are
used with the safety-alert symbol. DANGER identifies the
most serious hazards which will result in severe personal
injury or death. WARNING signifies hazards which could
result in personal injury or death. CAUTION is used to
identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to

7
616 01 1019 00
highlight suggestions which will result in enhanced
installation, reliability, or operation.
Introduction
The Observer® communicating system consists of several
intelligent communicating components which includes the
Observer® Wall Control, and Observer System HVAC
equipment such as, variable speed furnace or fan coil,
2-stage AC or HP, which continually communicate with each
other via a four-wire communication bus. Commands, oper-
ating conditions, and other data are passed continually
between components over the communication bus. The res-
ult is an enhanced level of comfort, versatility, and simplicity.
All communicating furnaces or fan coils are variable-speed
and multi-stage for maximum flexibility, efficiency, and com-
fort. They support controlled humidification, dehumidification,
and air quality control. Either an Observer communicating, or
a standard 24VAC controlled outdoor unit may be used.
When using conventional, single-stage outdoor units, the
communicating furnace (single-stage AC unit), or fan coil
(single-stage HP) provides the 24 volt signals needed to con-
trol them. Add the accessory daughter board to the system
to control other types of conventional outdoor units. All sys-
tem components are controlled through the wall mounted
Observer Control, which replaces the conventional thermo-
stat and provides the homeowner with a single wall control
for all features of the system.
The Observer Communicating Control with Wi-FiRnetwork
compatibility allows connection of this system to the Internet
viaahomeWi-FiRnetwork. See the Owner's Manual for
information on connecting the wall control to the home Wi-Fi

861601101900
network, and the MyObserverComfort web server. See later
in these Installation Instructions for information on applying
the accessory NAXA00101WA wireless access point, if the
existing home network is incompatible with this product.
The ability to remotely access and adjust the settings of
the Observer® wall control with the MyObserverComfort
web and mobile applications is dependent on the com-
patibility of the user’s computer/network or mobile de-
vice, the Observer wall control, and/or the MyObserver-
Comfort web server with, and the availability of, the
user’s Internet service provider or mobile device carrier
service. International Comfort Products makes no repre-
sentations or warranties, express or implied, including,
to the extent permitted by applicable law, any implied
warranty of merchantability or fitness for a particular
purpose or use, about the compatibility of the user’s
computer/network, or mobile device, with the Observer
wall control, and/or the MyObserverComfort web server,
with,andtheavailabilityof,theuser’sInternetservice
provider or mobile device carrier service, or that the
ability to remotely access and adjust the settings of the
Observer wall control will not be negatively affected by
the network-related modifications, upgrades, or similar
activity of the user’s Internet service provider or mobile
device carrier service.

9
616 01 1019 00
Quick Start
For first time installers, Quick Start will allow a quick start up
of the Observer® Control before learning all the details of
system operation. However, for the best possible comfort
and operation refer to the Owner’s Manual.
Set Day and Time
To set the current time and date, press SETUP;thenpress
TIME/DATE.

10 61601101900
A14558
Under date, you can select the month, day, or year buttons;
then use the ▲and ▼to select the appropriate date. . Un-
der time, you can select the hour, minute, and am/pm; then
use the ▲and ▼to select the appropriate time. You also
have the option of selecting between a 12 HR or 24 HR clock
format. Finally, you can choose whether you observe day
light savings time by pressing the ON or OFF button. Press