CE-IO1600 User Manual
1PRODUCT INTRODUCTION............................................................................................... 5
1.1 Features ...........................................................................................................................................5
1.2 Parameter.........................................................................................................................................5
1.3 Item Selection .................................................................................................................................6
1.4 Dimension........................................................................................................................................6
2WIRING INSTRUCTIONS..................................................................................................... 6
2.1 Terminal Definition.........................................................................................................................6
2.2 RS485 Communication Wiring.....................................................................................................6
2.3 DO Wiring.........................................................................................................................................7
3ETHERNET CONFIGURATION&COMUNICATION TEST........................................ 7
3.1 Ethernet Parameter Config...........................................................................................................7
3.1.1 Direct mode ........................................................................................................................................ 7
3.1.2 Networking mode............................................................................................................................. 11
3.1.3 TCP/UDP Configuration..................................................................................................................14
3.2 Communication Test....................................................................................................................18
3.2.1 Test Software...................................................................................................................................18
3.2.2 Network Test Tool............................................................................................................................18
3.2.3 Modbus TCP Testing ......................................................................................................................25
3.3 Device Address.............................................................................................................................28
3.3.1 Download..........................................................................................................................................28
3.3.2 Revise Address................................................................................................................................28
3.4 PLC Communication....................................................................................................................28
4DEVELOPMENT DATA INSTRUCTION........................................................................29
4.1 Flash On Flash Off Mode ............................................................................................................29
4.2 Modbus Register Instruction......................................................................................................29
4.3 Command List...............................................................................................................................31
4.4 Command Details.........................................................................................................................32
4.4.1 Control DO........................................................................................................................................ 32
4.4.2 Query DO Status .............................................................................................................................32
4.4.3 Flash ON Flash OFF Command....................................................................................................33
4.4.4 All ON and All OFF Command.......................................................................................................34
5PRODUCT MAINTENANCE..............................................................................................34

3
/ 13
CE-IO1600 User Manual
5.1 Device Usage Environment ........................................................................................................34
6AFTER-SALE SERVICE.....................................................................................................34
6.1 Commitment..................................................................................................................................34
6.2 Disclaimer......................................................................................................................................35
7UPDATE HISTORY...............................................................................................................35

4
/ 13
CE-IO1600 User Manual
Notice
❖Please read this manual carefully before use and save it for reference.
❖Please follow to the operating procedures and precautions in this manual.
❖Please open the package carefully and check whether the device and accessories have been
damaged due to transportation when you receive the device.
Please contact us for return processing once damage occurs.
❖Please do not repair it yourself, and contact our technical support department directly if the
device fails.
❖Manual and Config Tool download link:
https://onefexindustrial.com/ethernet-io-module

5
/ 13
CE-IO1600 User Manual
1 Product Introduction
CE-IO series products are Ethernet I/O module using standard Modbus RTU/TCP protocol,
integrates DO (digital output), DI (digital input), AI (analog input).
The communication method supports Ethernet networking, 7~40V wide voltage power
supply, and supports functions such as logic control between analog acquisition and relay
output.
Widely used in farms, agricultural greenhouses, IoT terminals, water conservancy,
electricity, gas collection and control and other application scenarios, its unique logic control
function can easily realize automatic water supply, fertilization, start and stop valves It is an ideal
device for small automatic control scenes.
1.1 Features
◆DC 7-40V wide voltage power supply, support anti-reverse connection;
◆16* DO contact isolation, normally ON and normally OFF, 10A 250VAC / 10A 30VDC;
◆LED indication, 1 for power and working status; 16 leds for DO status;
◆SupportsRS485+EthernetCommunicationinterface,powerisolationplussignalisolation,reliable
communication;
◆Communication baud rate: 300bps~38400bps (, It is 9600 by default and can be
modified by software);
◆Supportstandard ModbusRTU/TCPprotocol,readand write by registeraddress;
◆Support input and output linkage, such as local linkage or dual-computer linkage, which is
convenient for multi-terminal control;
◆Support flash ON flash OFF;
◆Supporting setting software for setting parameters and IO control;
◆Support software and hardware customization.
1.2 Parameter
Paremater
Contact capacity
10A/30VDC;10A/250VAC
Durability
100,000 times (Electrical)
10,000,000 times (Mechanical)
Data interface
RS485/Ethernet
Default IP
192.168.16.254
Working Voltage
DC 7-40V
Power / work indication
1 red LED
(power, always on; working, flashing)
Output indication
16 red LEDs (relay on and off)
Working temperature
-40℃~85℃, Industrial Grade
Size
180*94*41mm
Weight
450g
Default communication format
9600,n,8,1
Baud rate
300~38400bps
Software support
Setting and control software;
Support various configuration software;
support Labviewd, etc.

6
/ 13
CE-IO1600 User Manual
Installation
35mm Din Rail Mounting / Screw Holes
1.3 Item Selection
CE-IO0222
2*DI&2*DO&2*AI, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT
CE-IO0222S
2*DI&2*DO&2*AI, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT,
Timing Control, DI/AI&DO Linkage
CE-IO0222SC
2*DI&2*DO&2*AI, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT,
Timing Control, DI/AI&DO Linkage, Cloud
CE-IO4444
4*DI&4*DO&4*AI&4*AO, RS232+Ethernet, Modbus RTU/
TCP/UDP/MQTT, Timing Control, DI/AI&DO Linkage
CE-IO1600
16*DO, RS485+Ethernet, Modbus RTU/ TCP/UDP/MQTT
1.4 Dimension
180*94*41mm
2 Wiring Instructions
2.1 Terminal Definition
2.2 RS485 Communication Wiring

7
/ 13
CE-IO1600 User Manual
2.3 DO Wiring
3 Ethernet Configuration&Comunication Test
3.1 Ethernet Parameter Config
Ethernet
IP Address
Network
Mode
Port#
Device
Address
192.168.1.232
TCP
Server
10000
1
There are 2 modes for ethernet parameter configuration
Hardware
Connection
Instuctions
Direct mode
The io is directly connected to computer
through a network cable
Networking mode
The io is connected to the router/switch via a
network cable
3.1.1 Direct mode
Open [Network and Sharing Center]---->[Change Adapter Settings]---->[Local Area Connection]--
-->[Properties]---->[IPV4], modify the computer IP to static IP: 192.168.1.10;
(Because the default IP of io is 192.168.1.232, when modifying its parameters, the io IP must be
in the same network segment as the computer IP.

8
/ 13
CE-IO1600 User Manual
➢Open JYNetConfigEn, it shows as below:

9
/ 13
CE-IO1600 User Manual
➢Chosse Local connection:
➢Searching:

10
/ 13
CE-IO1600 User Manual
➢Revise parameter
➢researching
Inhaltsverzeichnis
Andere OneFex E/A-System Handbücher
Beliebte E/A-System Handbücher anderer Marken

WAGO
WAGO 750-344 Bedienungsanleitung

Teknim
Teknim TWM-1887 Bedienungsanleitung

Intelligent Appliance
Intelligent Appliance IA-2662-E Bedienungsanleitung

BERGHOF
BERGHOF ECC DIO 16/16 Bedienungsanleitung

Advantech
Advantech PCM-27J3AU Installations- und Betriebshandbuch

Festo
Festo CP-E08-M12-CL Bedienungsanleitung