Oxygen Wheel Chair Ready Type Chamber Bedienungsanleitung

PO Box 2301, Naperville, IL 60540
USA
(630) 452-8431
SalesTeam@HyperbaricPro.com
www.HyperbaricPro.com
AIR
COMPRESSOR
AIR DEHUMIDIFIER

HYPERBARIC
Oxygen Chamber
Please read this manual to its entirety before using the system for the rst time. Keep this
manual handy for your reference. Please ensure that all items are removed from the box
before trowing the box away. Some customers have thrown away the protective padding
provided to protect the zipper when rolling the Wheelchair in and out of the chamber.

3
1. Foreword
2. Symbols
3. Safety Notice
4. Product Specications and Construction Chamber
Air Compressor
Oxygen Concentrator
Dehumidier
5. Product Assembly and Operation
6. Preparing before hyperbaric therapy
7. Maintenance and Cultivation
8. FAQ
9. Faults and Troubleshooting
10. Condition for Transportation and Storage
4
4
5
6
7
9
11
12
13
14
14
CONTENTS
Installation
Working Scheme
Accessories
Air Compressor and Oxygen Concentrator Connection
Frame Installation
Silencer and Oxygen Mask Installation
Dehumidier Installation
Water Drainer
Operation
Chamber maintenance and cleaning
Air Compressor Maintenance and Cleaning

4
1. FOREWORD
2. SYMBOLS
A NEW CONCEPT OF HEALTH AND BEAUTY.
Congratulations on your purchase of your Hyperbaric chamber from Oxygen Health Systems. Below you will find
instructions for installing and operating our Hyperbaric chamber with the Air Conditioning . We have also added links
to videos on some of our steps to provide additional insight into installation steps. Our support team is always available
to assist with any questions you might have during the installation process.
The following table is a list of symbols and definitions that used with the Hyperbaric Chamber.
MILD HYPERBARIC OXYGEN THERAPY.
Authorized
Representative In
The European
Community
HOT Surface
Do Not Touch
Allow to Cool Before
Servicing
Exhaust
Caution
Upward
Keep Dry
Date of
Manufacture
Refer to instruction
Manual / Booklet
Protective Earth
(Ground)
On
Type B Applied
Part
Manufacturer
CE Certication
Serial number
Mains fuse
Specication
Off
Intake
Warning
Air Deate Valve
Indicator Internal/
External
Correct Disposal of This Product
(Waste Electrical & Electronic
Equipment) Statement: Contact the
local authorities to determine the
proper method of disposal of
equipment and its part

3. SAFETY NOTICE
In order to ensure safety, please read the following precautions before use
WARNING
PROHIBIT THE USE UNDER THE FOLLOWING CONDITIONS
• Abnormal smell during use - Please turn off the power and pull out the plug.
• Please make sure the socket plug is fully inserted.
• Please do not disassemble the machine without permission from the supplier.
• This product needs to stay away from water and re and sharp objects.
• Children should only use under adult supervision with consent of a physician.
• Please do not touch any valves on the chamber while using.
• Please do not place heavy objects on the machine.
• Do not use if the wire is loose.
• Do not pull or twist the power cord.
• Hand wet do not touch the power plug and switch.
• Do not use it in a bathroom or other damp environment.
• 1. Pregnant women and people with severe infectious diseases and patients
• 2. Bad colds, Pneumothorax patients
• 3. Patients with severe emphysema
• 4. Hypertension exceeds 160 / 100ml
• 5. Severe heart problems
• 6. Severe COPD ( Mild COPD is OK)
Notice
1. In the chamber, when the pressure is rising, the patients ears need to release pressure or they may experience
pain, just like the feeling of taking a plane up and down. This is normal. The following methods can be used to
alleviate pain and help balance pressure: A. Yawn; B. Chewing gum, C. Pinch nose and blow, D. Open the Air deate
valve to slow down ination if required. Once the pressure is stable at 30 KPa, This discomfort will gradually disappear.
2. Zippers can be opened only when the chamber has depressurized to 0 KPa.
Open the Valve Make sure that Pressure
Gauge Appears 0 KPa
After get out of the chamber, please turn off the power immediately after use, cleaning work in a timely manner.
P
l
e
a
s
e
r
e
l
e
a
s
e
p
r
e
s
s
u
r
e
b
e
f
o
r
e
p
u
l
l
i
n
g
t
h
e
z
i
p
p
e
r
s
Pull the Zippers
5

1. Cover
2. Oxygen Inlet Valve
3. Air Inlet Valve
4. Viewing Window
5. Anti-Roll Bolster
6. Zipper
7. Air Deate Valves
8. External Pressure Gauge
(BLUE --attach externally)
9. Internal Pressure Gauge
(BLACK --attach from inside)
10. Mufer / Silencer
11. Blank Port reserved for
future upgrades
12. Automatic Pressure Relief Valves
4. PRODUCT SPECIFICATIONS AND CONSTRUCTION
2. AIR COMPRESSOR
Voltage 110 / 220V
Air Flow 72 L / Minute
Power 400 W
Weight 18 KG
Model:
Size:(Chamber)
Size:(Door)
Pressure:
Weight:
140(L) * 100(H) * 160(W) cm
78(H) * 100(W) cm
1.3 ATA /4 PSI /30 Kilo Pascal
13 Kg
Wheel Chair Ready Type Chamber
1. CHAMBER
10
3
2
4
987
4
6
5
1
12
11
6

5. PRODUCT ASSEMBLY AND OPERATION
4. Dehumidier
Voltage 110/220V
Capability 150 L / Minute
Pressure 0.8mPa
Power 300 Watt
Weight 5kg / 12 LPS
Working Scheme
Installation
1. Please open the accessory box before installation accessories
7

2. Start the installation of the frame per the videos provided.
If two people are present for installation, have one person hold the chamber Bag Up
while installing the Frame.
Some users may wish to inflate the chamber whole installing the frame.
Install the end pieces first and then the horizontal pieces.
Note: Please install internal and external pressure gauges before use (the internal pressure gauge should
be installed inside the chamber, external pressure gauge should be installed outside the chamber)
3. Connect the air tube on the air compressor to the air inlet valve of the chamber.
Install internal & external pressure gauges.
4. Install mufer / silencer to the
compressor air inlet valve inside
the chamber.
External
Pressure Gauge
(0 - 40 Pa)
Internal
Pressure Gauge
( -40 - 0 Pa)
Mufer
/ Silencer
Oxygen
Mask
8

5. From the Exterior, Connect the Tubes with Air Compressor (Image 5.a), dehumidier and Chamber
as in the diagram below. Please connect air tubes from Air Compressor to the wet Air In Port of
Dehumidier and Connect air tubes from Chamber to the Dry Air Out port of Dehumidier.
There is water drainer on one side of the Dehumidier. Unscrew (Image 5.b) the black valve to drain
the Water when the drainer is full of water per the diagram on the right.
WET AIR IN
DRY AIR OUT
(Image 5.a) (Image 5.b)
5. PRODUCT ASSEMBLY AND OPERATION
Operation
1. Switch on the machines and adjust the oxygen generator 1 LPM below the maximum setting.
2. Get into the chamber and pull outside zippers and then the inside zippers closed and (make sure
to atten out the silicone strip between the zippers)
2A. Close the air deate valve
Zippers and Air Deate Valve can be operated both inside and outside the chamber.
or
Pull the inside and
outside zippers
Close the internal
pressure relief valve
anti-clockwise
Close the external
pressure relief valve
clockwise
P
l
e
a
s
e
r
e
l
e
a
s
e
p
r
e
s
s
u
r
e
b
e
f
o
r
e
p
u
l
l
i
n
g
t
h
e
z
i
p
p
e
r
s
ATTENTION: During Operation, once the Hyperbaric Chamber reaches its optimal pressure, per
design excess pressure is released outside the chamber. Hence, any pressure release sound through
the valves while in use is normal.
ON/OFF
ON/OFF
9

3. Sit down and wear oxygen headset or mask.
4. In about 10 mins, the chamber pressure gauge will slowly rise up to 30 KPa, at this time the
automatic pressure release valve will exhaust air automatically and stablize the pressure betwen
30 KPa and 32 KPa
5. It is recommended to use 40-80 mins per session.
(Pressure gauge error tolerance 3 KPa)
40-80mins
6. After use, please open the Air Deate Valve to reduce pressure rst.
open the external air deate
valve anti-clockwise
or
Open the internal air deate
valve clockwise
P
l
e
a
s
e
r
e
l
e
a
s
e
p
r
e
s
s
u
r
e
b
e
f
o
r
e
p
u
l
l
i
n
g
t
h
e
z
i
p
p
e
r
s
10
Inhaltsverzeichnis
Beliebte Sauerstoffgeräte Handbücher anderer Marken

DeVilbiss
DeVilbiss iFILL PD1000A Series Handbuch