Paradyne FrameSaver SLV 9820-C Bedienungsanleitung

1
FrameSaverSLV 9820 Standalone Unit
Installation Instructions
Document Number 9820-A2-GN10-20
August 1999
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select
Library
→
Technical Manuals
→
FrameSaver Frame Relay Devices.
Select the following document:
9820-A2-GB20
FrameSaver SLV
9820
User’s Guide
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
FrameSaver SLV 9820 Models
There are two models of the FrameSaver 9820 product:
Model 9820-C – Central site model. Supports up to 120 PVCs.
Model 9820 – Remote site model. Supports up to 16 PVCs.
Package Checklist
Verify that your package contains the following:
FrameSaver SLV 9820 or 9820-C unit
Universal power supply with an attached cable and ferrite choke
Power cord appropriate for the wall-plug standard in your country (depends on
model ordered).

2
COM port-to-PC cable – DB9 connector (14 feet – 4.3m)
Ferrite choke
FrameSaver SLV
9820 Quick Reference
(Document No. 9820-A2-GL10)
Additional cables may be ordered. See
Cables You Can Order
on page 3 when
ordering cables.
Be sure to register your warranty at www.paradyne.com/warranty.
Before You Begin
If you ordered a wall mounting kit (Feature No. 9001-F1-891) for your FrameSaver unit,
install the wall mounting before you start installing the unit. Follow the same guidelines
below when installing the wall mounting. Contact your sales representative to order this
feature.
Before starting the installation, make sure you have:
A dedicated, grounded power outlet that is protected by a circuit breaker within
6 feet of the FrameSaver unit.
A clean, well-lit, and ventilated site that is free from environmental extremes.
One to two feet of clearance for cable connections.
A physical connection to the frame relay network via an NTU, with either an
EIA-530, V.35 or an X.21 user interface. This connection is made using the
appropriate cable attached to the Network port of the FrameSaver unit.
This cable is not supplied with your FrameSaver unit, and you will need to order
the appropriate cable kit for your application, V.35, X.21, or EIA-530 (see page 3
for the Feature No. you need to order).
An async (asynchronous) terminal or PC (personal computer) to set up the
access unit.
Node IP Addresses and Subnet Masks (see your network administrator).
See the User’s Guide for additional information on:
Troubleshooting
Technical Specifications
Cables, Connectors, and Pin Assignments

3
Cables You Can Order
If connecting to . . . Order a . . . Feature
Number Part
Number
LAN adapter Adapter DB25
plug-to-8-position
modular receptacle
3100-F1-920 002-0069-0031
COM Port-to-LAN
adapter cable
(14 feet – 4.3 meters)
3100-F2-910 035-0315-1431
Equipment with
X.21 interfaces,
DB15 connectors
X.21 cable kit, which
includes a:
X.21 network cable
(10 feet – 3 meters)
X.21 DTE
adapter cable,
EIA-530A-to-X.21
(1 foot – .3 meters)
9008-F1-521
035-0384-1031
035-0302-0131
Equipment with
V.35 interfaces,
MS34 connectors
V.35 cable kit, which
includes a:
V.35 network cable
(10 feet – 3 meters)
V.35 DTE adapter,
EIA-530A-to-V.35
9008-F1-522
035-0383-1031
002-0095-0031
Equipment with
EIA-530 interfaces,
DB25 connectors
EIA-530 straight-through
cable
(10 feet – 3 meters)
9008-F1-523 035-0385-1031
Contact your sales representative to order cables.
Safety Instructions
Please refer to the
Important Safety Instructions
beginning on page 17.

4
Installing the Power Supply and Cord
1. Insert the power supply’s 4-prong plug into the POWER jack.
When inserting the plug at the rear of the FrameSaver unit, align the plug with the
notch above the POWER jack. Make sure the locking tab snaps securely into the
jack.
98-16197
Power Cord /
Transformer
(FrameSaver 9820
Shown)
OK
ALM
Locking
Tab Grounded
Power
Outlet
2. Insert the socket end of the power cord into the power supply’s receptacle.
3. Plug the power cord into the grounded power outlet.
Verification Check:
Did any LEDs light?
– If yes, the FrameSaver unit has power.
– If no, refer to
Troubleshooting
in the User’s Guide.

5
Connecting the COM Port to an Async Terminal or PC
The FrameSaver unit must first be directly connected to a PC or asynchronous terminal
(providing VT100 terminal emulation) to set up access and management of the unit.
1. Configure the VT100-compatible terminal or PC to be compatible with the
access unit:
– Baud Rate set to 19.2 kbps.
– Character length set to 8 data bits.
– Parity set to none.
– Stop bit set to 1.
– Flow Control set to None.
2. Insert the DB25 end of the EIA-232 cable into the FrameSaver unit’s COM port.
99-16198-01
To Connect to a PC
or Async Terminal
COM
Port
(FrameSaver 9820
Shown)
3. Insert the other end of the cable into the PC or VT100-compatible terminal.
4. Tighten the screws on each side of the connector to secure them.
5. Install the ferrite choke as close to the COM port connector as possible, making
sure the choke snaps shut around the cable.
6. Press Enter (or Return, depending on your keyboard) to display the Main Menu.
Verification Check:
Did the Main Menu appear?
– If yes, continue with the installation.
– If no, recheck terminal and FrameSaver unit compatibility (see settings in
Step 1), or press the Enter key.
Refer to
Troubleshooting
in the User’s Guide for other possible explanations.

6
A Quick Guide to Configuration
The FrameSaver unit should operate using the default (factory-set) configuration
options, with exception to the changes specified in these installation instructions. Refer
to the following table for help in navigating through the menus.
Press the . . . To . . .
Esc key Go back one screen or menu level. To see a visual
representation of the menu levels, see
Menu Hierarchy
in
the
FrameSaver 9820 Quick Reference
.
Tab key, or
Up (↑), Down (↓),
Left (←) and Right (→)
arrow keys
Move the cursor from one menu item to the next.
Enter or Return key Complete the menu or option selection.
Spacebar Display the next available setting when changing a
configuration option. All the available settings for an
option appears at the bottom of the screen.
As an example, follow these steps to go to the Configuration Edit/Display menu so you
can start setting up the unit. To load a configuration for editing:
1. From the Main Menu, press the down arrow key twice so the cursor is on
Configuration.
2. Press Enter to display the Configuration menu. The Load Configuration From
menu appears.
3. Press Enter to select Current Configuration (the cursor is already on this
selection). The Configuration Edit/Display menu appears.
This sequence of steps would be shown as the menu selection sequence:
Main Menu
→
Configuration
To save a configuration option change:
1. Press Ctrl-a to switch to the function keys area at the bottom of the screen.
2. Type sor S(Save) and press Enter. The Save Configuration To menu appears.
3. Press Enter again to save your changes to the Current Configuration.
4. Press Esc until the Configuration Edit/Display menu reappears to continue
configuring the unit.
Press Ctrl-a, type m(MainMenu), and press Enter to return to the Main Menu.
In the sections that follow, only the minimum option changes required are included so
you will have a quick and trouble-free installation. See the configuration option tables in
the User’s Guide for more information about configuration options.

7
Installing and Setting Up the 9820 FrameSaver Unit
The following sections guide you through installation and setup of a FrameSaver unit.
It is assumed that the FrameSaver unit is configured for factory default settings at the
start of installation.
For correct operation of the unit’s Hardware Bypass feature, both the network and user
port interface types need to be the same, and the combined length of their cables
should not exceed the maximum length limitation for the interface type (EIA-530A, V.35,
or X.21). In addition, both the source and primary destination DLCI numbers need to be
the same.
See the following illustration for an example of a network that includes FrameSaver
units at the central site (e.g., the company’s headquarters in Munich) and the remote
sites (e.g., branch offices in London and Singapore). User data PVCs provide
LAN-to-LAN connectivity between the central site and the remote sites.
Frame
Relay
Router Central Site
FrameSaver
Unit
NMS
Munich
Headquarters
Port NET
NTUNTUNTU NET Port
Frame
Relay
Router
Remote Site
FrameSaver
Unit
London Office
DLCI/EDLCIs:
100/0 User Data
100/2 Management Data
NTUNTUNTU
London OfficeLondon Office
NTUNTUNTU NET Port
Frame
Relay
Router
Remote Site
FrameSaver
Unit
Singapore Office
DLCI/EDLCIs:
200/0 User Data
200/2 Management Data
Frame
Relay
Network
100
200
DLCI/EDLCIs:
100/0 User Data for London
200/0 User Data for Singapore
100/2 Management Data for London
200/2 Management Data for Singapore
98-15989-01
NTU
From a network management perspective, the central site FrameSaver unit should be
configured for management from a Network Management System (NMS), through
either the attached router as shown in the above figure, or through the Network
Operations Center (NOC) router (for management by the Network Service Provider).
Multiple management PVCs then connect the central site unit to the remote site units
using Paradyne’s proprietary PVC multiplexing method (embedded DLCIs).

8
Verifying that Self-Test Passed
1. Follow this menu selection sequence from the Main Menu and press Enter after
each selection:
Main Menu
→
Status
→
System and Test Status
2. Check the Self-Test Results column (in the center of the System and Test Status
screen).
– If Passed appears, the FrameSaver unit successfully completed the self-test.
– If any failure messages appear in this column, reset the unit by disconnecting,
then reconnecting the power cord. The unit will perform the self-test again. If the
failure reappears, call your service representative for assistance.
Setting the System Clock
To set up the system clock:
1. Select System Information.
Main Menu
→
Control
→
System Information
2. Move the cursor to the Date, then the Time field to enter:
– Date in the mm/dd/yyyy format (month/day/year)
– Time in the hh:mm format (hours:minutes)
3. Save the settings.
Assigning the Node IP Address
1. Set up the node.
Main Menu
→
Configuration
→
Management and Communication
→
Node IP
2. Minimally, enter the following options:
– Node IP Address
– Node Subnet Mask
3. Save the configuration.

9
Configuring Physical Interfaces
The network and data port interfaces support three different port types: EIA-530, V.35
and X.21. If your application does not use V.35 interfaces, then the port type needs to
be changed. If the Hardware Bypass feature will be used, both the network and user
port interfaces should use the same type of interface. The port type is specified in the
physical configuration options.
To configure the physical interfaces:
1. Select the Network physical configuration options.
Main Menu
→
Configuration
→
Network
→
Physical
2. Select the appropriate Port Type.
3. Press Ctrl-a and Save your change(s).
4. Return to the Configuration Edit/Display menu.
5. Repeat Steps 2–4 for the data port.
Main Menu
→
Configuration
→
Data Ports
→
Physical
6. Return to the Configuration Edit/Display menu.
Setting Up Management
1. Select General SNMP Management.
Configuration
→
Management and Communication
→
General SNMP Management
2. Minimally, set Name 1 Access to Read/Write.
3. Save the configuration.

10
Setting Up Local Management at the Central Site
1. Create a DLCI for the data port.
Configuration
→
Data Ports
→
DLCI Records
2. Save the configuration.
3. Create a Management PVC using the data port DLCI just created.
Configuration
→
Management and Communication
→
Management PVC
Minimally, enter the following options:
– Name for the management PVC
– Interface IP Address and Subnet Mask, if different from the Node’s
– Primary Link for this Management PVC (the user data port)
– Primary DLCI (i.e., the data port DLCI)
4. Save the configuration.
Automatic Configuration
The FrameSaver unit provides several automatic configuration features. Frame Relay
Discovery and configuration is one of these features.
Main Menu
→
Auto-Configuration
The default discovery mode is 1MPort. In this mode, for each DLCI discovered on the
network, a multiplexed network DLCI and a standard data port DLCI will be configured
and connected, and a Management PVC will be embedded in the network DLCI.
NOTE:
When auto-configuration creates a multiplexed DLCI, but a standard DLCI is
needed, change the DLCI to standard from the network DLCI Records screen:
Configuration
→
Network
→
DLCI Records
Other modes can be selected. See
Setting Up Automatic Configuration
in
Setup
of the
User’s Guide for information about other modes and how the Frame Relay Discovery
Mode can be changed.
No automatic configuration occurs until the network cable is connected. If you do not
want management links configured or automatic configuration, change the default
setting for the Frame Relay Discovery feature.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Paradyne Touch-Terminal Handbücher
Beliebte Touch-Terminal Handbücher anderer Marken

Wincor Nixdorf
Wincor Nixdorf iPOS plus Advanced Bedienungsanleitung

Ingenico
Ingenico AXIUM EX4000 Bedienungsanleitung

Heisei Electronics
Heisei Electronics Q-POS 815 Bedienungsanleitung

Amano
Amano MTX-15 Bedienungsanleitung

FLOWBIRD
FLOWBIRD CWT Compact Touch Bedienungsanleitung

Demco
Demco SP7 Bedienungsanleitung

Motorola
Motorola MTP850 Bedienungsanleitung

YASKAWA
YASKAWA 62H-MDC0 Bedienungsanleitung

MVG industries
MVG industries NeptuLink Bedienungsanleitung

Price Industries Limited
Price Industries Limited FDC Gebrauchsanweisung

Honeywell
Honeywell TemaKey Bedienungsanleitung

EBN
EBN BPC65-B-A16G Bedienungsanleitung






