1. SAFETY............................................................................................................................................... 1
2. TECHNICAL INTRODUCTION............................................................................................................ 2
2.1 Features......................................................................................................................................... 2
2.2 Factory Options ............................................................................................................................. 2
3. INSTALLATION.................................................................................................................................... 3
3.1 Inspection and Test........................................................................................................................ 3
3.2 Functional Self Test ....................................................................................................................... 4
3.3 Mounting ........................................................................................................................................ 4
4. FRONT PANEL.................................................................................................................................... 4
4.1 Front Panel List.............................................................................................................................. 4
4.2 Indicator LEDs ............................................................................................................................... 4
4.3 Liquid Crystal Display .................................................................................................................... 5
4.4 Keypad........................................................................................................................................... 5
4.5 Common Interface ......................................................................................................................... 5
5. REAR PANEL ...................................................................................................................................... 6
5.1 Power Supply................................................................................................................................. 6
5.2 Output Connectors......................................................................................................................... 6
5.3 ASI Input Connector....................................................................................................................... 7
5.4 RS-232 Interface............................................................................................................................ 7
5.5 Ethernet Interface .......................................................................................................................... 7
5.6 TS/IP Interface (Factory Optional) ................................................................................................. 7
6. INSTALLATION.................................................................................................................................... 7
6.1 Main Menu ..................................................................................................................................... 7
6.2 System Menu................................................................................................................................. 8
6.2.1 Local Setup ............................................................................................................................. 8
6.2.2 Setting up the Trap IP Address ............................................................................................... 8
6.2.3 Editing the Unit Name............................................................................................................. 9
6.2.4 Checking the Properties ......................................................................................................... 9
6.2.5 Recover Factory Default Settings ........................................................................................... 9
6.2.6 Setting Machine Type ............................................................................................................. 9
7. Manual for DCH-4000P-30S /-30T/-30C/-30S2 .................................................................................. 9
7.1 Menu Structure for DCH-4000P-30S /-30T/-30C/-30S2................................................................ 9

7.2 Setting Inputs for DCH-4000P-30S /-30T/-30C/-30S2 .................................................................11
7.2.1 Checking Status of Inputs ......................................................................................................11
7.2.2 Setting the Tuner Parameters................................................................................................11
7.3 Setting Outputs for DCH-4000P-30S /-30T/-30C/-30S2.............................................................. 13
7.3.1 Checking Status of Outputs .................................................................................................. 13
7.3.2 Setting Common Interface .................................................................................................... 14
7.3.3 Setting the Parameters of Decoder ...................................................................................... 14
7.3.4. Setting the ASI1 Output ....................................................................................................... 15
7.3.5. Setting the ASI2/SDI Output ................................................................................................ 15
7.3.6. Setting the Mux/Filter........................................................................................................... 15
8. Manual for DCH-4000P-41S /-41T/-41C/-41S2 ................................................................................ 15
8.1 Menu Structure for DCH-4000P-41S /-41T/-41C/-41S2.............................................................. 15
8.2 Setting Inputs for DCH-4000P-41S /-41T/-41C/-41S2 ................................................................ 18
8.2.1 Checking Status of Inputs ..................................................................................................... 18
8.2.2 Setting the Tuner Parameters............................................................................................... 18
8.2.3 Setting the Ethernet Connector ............................................................................................ 18
8.3 Setting Outputs for DCH-4000P-41S /-41T/-41C/-41S2.............................................................. 19
9. Manual for DCH-4000P-42S /-42T/-42C/-42S2 ................................................................................ 19
9.1 Menu Structure for DCH-4000P-42S /-42T/-42C/-42S2.............................................................. 19
9.2 Setting Inputs for DCH-4000P-42S /-42T/-42C/-42S2 ................................................................ 21
9.3 Setting Outputs for DCH-4000P-42S /-42T/-42C/-42S2.............................................................. 22
9.3.1 Setting the Ethernet TS over IP output ................................................................................. 23
9.3.2 Other output settings for DCH-4000P-42S /-42T/-42C/-42S2 .............................................. 23
10. REMOTE MONITORING AND CONTROL...................................................................................... 23
10.1 Install HDMS to a PC................................................................................................................. 23
10.2 Connect to HDMS...................................................................................................................... 23
10.3 Login to HDMS .......................................................................................................................... 24
10.4 Add DCH-4000P-xx to HMDS.................................................................................................... 24
10.5 DCH-4000P-xx in HDMS ........................................................................................................... 24
10.6 Other Settings............................................................................................................................ 25
11. FAQ.................................................................................................................................................. 25
12. Appendix.......................................................................................................................................... 25
12.1 Specification............................................................................................................................... 25

DCH-4000P-xx series Receivers
- 1 -
W
WW.PBI-CHINA.COM
1. SAFETY
Please read this chapter before installation and use of the device
This equipment is provided with a protective earthing ground incorporated in the power cord.
The main plug shall only be inserted in a socket outlet provided with a protective earth contact.
Any interruption of the protective conductor, inside or outside the device, is likely to make the
device dangerous.
The device described in this manual is designed to be used by properly-trained personnel
only. Adjustment, maintenance and repair of the device shall be carried out by qualified
personnel.
No operator serviceable parts inside. Refer servicing to qualified personnel. To prevent
electrical shock, do not remove covers.
For the correct and safe use of the device, it is essential that both operating and servicing
personnel follow generally accepted safety procedures in addition to the safety precautions
specified in this manual.
Whenever it is likely that safety protection is impaired, the device must be made in-operative
and secured against unintended operation. The appropriate servicing authority must be
informed. For example, safety is likely to be impaired if the device fails to perform the
intended measurements or shows visible damage.
WARNINGS
zDo not use the equipment in moisture environment surroundings.
Avoid direct contact with water.
zNever place the equipment in direct sunlight.
zThe outside of the equipment may be cleaned using a lightly dampened cloth. Do not use
any cleaning liquids containing alcohol, methylated spirit or ammonia etc.
zFor continued protection against fire hazard, replace line fused only with same type.

DCH-4000P-xx series Receivers
- 2 -
W
WW.PBI-CHINA.COM
2. TECHNICAL INTRODUCTION
DCH-4000P-xx is a professional IRD with a variety of input (including DVB over ASI, IP,
QPSK, QAM, COFDM and DS3) and output (CVBS, SDI, ASI, DS3 and IP) combinations. An
appropriate IP port equipped as an option supports DVB over IP applications. LAN control
and monitoring are achieved with TCP/IP, SNMP and HDMS*.
(*Headend Devices Management System, a remote management software)
2.1 Features
zFully complies with MPEG-2, MP@ML and DVB-S/-T/-C standards
zIP input or output with UDP/RTP (optional)
zMulticast and Unicast on IP
zSupports PAL, NTSC or SECAM
zSupports various Conditional Access systems
zSDI video output with digital audio embedded
zTwo sets of independent ASI outputs
zAutomatic PMT update
zCompatible with Multiple De-encrypt CI modules
zDS3 I/O for TS (optional)
zSwitchable audio sound track
zTeletext VBI, EBU subtitle and DVB subtitle
zUpgradeable through LAN
zEasy-to-use LCD menu
2.2 Factory Options

DCH-4000P-xx series Receivers
- 3 -
W
WW.PBI-CHINA.COM
Figure 2.1 Factory Option list of DCH-4000P series
3. INSTALLATION
Warning:
This equipment is provided with a protective earthing ground incorporated in the power cord.
The main plug shall only be inserted in a socket outlet provided with a protective earth contact.
Any interruption of the protective conductor, inside or outside the instrument, is likely to make
the instrument dangerous. The type of main plugged shipped with each instrument depends
on the country of application.
Caution:
Do not connect AC power until you have verified that the line voltage is correct and the proper
fuses are installed. The equipment requires a power source of either 50/60 Hz at 110V or
50/60 Hz at 240V. The voltage ranges for these nominal voltage values are shown in the
table:
POWER REQUIREMENT
Input voltage 90-260 Vrms auto select
Frequency 47 to 63 Hz
Power 50 VA max. / 30 VA typical.
Current 110 V/0.27A or 240 V/0.125A typical
Caution:
Be sure the supply voltage is within the specified range.
Checking the fuses:
The recognized recommended fuses are size 5 by 20 mm, rate T 2.0A, 250 V (UL and IEC
approved).
The line fuse is housed in a small container besides the power connector on the rear panel.
To check the fuse, insert the tip of a screwdriver in the slot at the middle of the container and
pry gently to extend the fuse where there is a little tap and pull out the fuse gently. The fuse is
attached to the line module and cannot be removed.
3.1 Inspection and Test
Check if the devise has any visible damage. If everything seems all right, power can be
applied to the device. The main socket and fuse are located at the rear panel of the device.
When the device is turned on, verify that the display shows the following message:
DCH-4000P (factory default unit-name)
IP: 168.192.1.21 (factory default IP Address)
If no message is shown in the display or there is not light in the display, the device is

DCH-4000P-xx series Receivers
- 4 -
W
WW.PBI-CHINA.COM
defective and has to be returned for servicing.
3.2 Functional Self Test
No specific functional self test is needed.
The device has been factory tested according to recognized test procedures and is ready for
operation.
3.3 Mounting
The environment should be relatively dust free, free of excessive vibration and the ambient
temperature between 0 ℃to 40 ℃. Relative humidity of 20% to 80% (non-condensed) is
recommended.
Air intake for cooling is achieved via holes at the side of the device and the fans inside. The
air flow should not be obstructed. Therefore, the device has to be placed on a flat surface,
leaving some space at the sides of the device.
When in operation, the internal temperature should not exceed the limit of 70 ℃.
4. FRONT PANEL
4.1 Front Panel List
Figure 4.1 Front Panel of DCH-4000P-xx Series Receiver
4.2 Indicator LEDs
There are 3 LED-indicators:
-POWER: the status of the power supply
green: the power is turned on
off : the power is turned off
-TUNER LOCK: the status of the tuner
green: The incoming QPSK is locked by the tuner.
off : there is no QPSK input signal or the signal is unlocked
-ALARM: the status of input signal source, which includes IP input, QPSK signal input and
DVB-ASI TS input.

DCH-4000P-xx series Receivers
- 5 -
W
WW.PBI-CHINA.COM
4.3 Liquid Crystal Display
The 2 x 20 character Liquid Crystal Display (LCD) shows all the required information about
the selected parameters.
The top row of the LCD shows the selected parameter. The bottom row indicates the present
values and how these can be adjusted.
The parameters are grouped in three menus:
-the Inputs, which gives the full operation on inputs parameters
-the Outputs, with the full operation control functions on outputs parameters
-the Systems, gives the general device management parameters and informs about the
device working status
4.4 Keypad
Figure 4.2 Keypad of DCH-4000P-xx series
The 6 keys on the front panel allow you to navigate in the information given on the LCD and
to change parameters, when the device operates under local control.
The <ENTER>-key is used to enter the main menu or a sub-menu. When you stand on the
preferred menu, <ENTER> is used to active the parameter on the bottom line and allows you
to change the value. It also finishes the input of new alphanumeric values and confirms the
changes.
The <>-and< >-keys are used to select between the main menus or sub-menus. When
you stand on the preferred menu and the parameter is active, they are also used to change
the numerical values. Selecting a digit with the <>-and < >-keys.
The <EXIT>-key, is used to exit a menu without any action.
4.5 Common Interface
There are two Common Interface slots. You can insert up to two different CAM modules for
descrambling.

DCH-4000P-xx series Receivers
- 6 -
W
WW.PBI-CHINA.COM
5. REAR PANEL
Figure 3.2 Rear Panel of DCH-4000P-xx Series
B1 TS/IP Input/Output interface
B2 XRL L interface
B3 XRL R interface
B4 RGB/YUV interface (G/Y)
B5 RGB/YUV interface (B/U)
B6 RGB/YUV interface (R/Y)
B7 CVBS2 Output interface
B8, B18 ASI2/SDI output interface
B9, B19 ASI1 output interface
B17 ASI input interface
B10 RS-232 interface
B11 Tuner Loop Out interface
B12 Tuner In interface
B13 Power socket, AC 90~260V
B14 CVBS1 Output interface
B15, B16 L-Audio-R interface
B20 Ethernet interface for remote management system
B21 Grounding
5.1 Power Supply
The power cord is inserted to an IEC main socket at the side of the device.
Check that the power cord is suitable for the country where the device will be used.
A standard power cord with a European DIN 49441 two pin main plug is delivered together
with the device.
The line fuses are housed in a small container at the side of the power supply connector.
5.2 Output Connectors
The ASI interface B9), B19) and ASI2 interface B8), B18) are two pairs of independent ASI
output. Both use female BNC connectors, with 75 Ohm impedance. The ASI interface B18)
and B19) are used as a redundant output of B8) and B9) out.

DCH-4000P-xx series Receivers
- 7 -
W
WW.PBI-CHINA.COM
Note: the B8), B18) interface could be configured as SDI with Audio embedded. Please refer
to Chapter 7.3.5.
5.3 ASI Input Connector
The ASI input B17) is a 75 ohm female BNC connector.
5.4 RS-232 Interface
This interface is a 9-pins female sub-D connector. The RS-232 interface is only used for
factory software upgrade and configuration, so you are not allowed to connect any cable to
the RS-232 connector, as that could damage the device.
5.5 Ethernet Interface
An RJ-45 connector B20) provides a remote control interface.
5.6 TS/IP Interface (Factory Optional)
An RJ-45 connector B1) provides a streaming stream over IP input or output.
6. INSTALLATION
The device allows you to configure, control and monitor through the Keypad and front panel
display when a remote control system is not used.
6.1 Main Menu
Turn on the device and wait for 8 to 10 seconds, while the device will complete self inspection
and configuration. The top row of the LCD shows the name of the device. The local IP address is
displayed on the bottom row of the LCD.
Note: the local IP address can be changed in the System Menu.
Use the <ENTER>-key to enter on the Main Menu. The <>-and< >-keys are used to choose
between the three main menus.
Andere Handbücher für DCH-4000P