PENKO 1020 Series Bedienungsanleitung

For more information visit
www.penko.com - technical support - literature library
1020
PENKO Engineering BV
The Leading Experts In Weighing & Dosing
Indicator
Manual

1020 Indicator
2
IMPORTANT SAFETY INFORMATION
READ THIS PAGE FIRST!
Penko Engineering manufactures and tests
its products to meet all applicable naonal
and internaonal standards. It is vital that
this instrument is correctly installed, used,
and maintained to ensure it connues to
operate to its opmum specicaon.
The following instrucons must be adhered
to and incorporated into your safety
program when installing, using, and
maintaining Penko products. Failure to
follow the recommended instrucons can
aect the system’s safety and may increase
the risk of serious personal injury, property
damage, damage to this instrument and
may invalidate the product’s warranty.
• Read the instrucons fully prior to
installing, operang, or servicing the
product. If this Instrucon Manual is not the
correct manual for the Penko product you
are using, call 0031(0)318-525630 for a
replacement copy. Keep this Instrucon
Manual in a safe place for future reference.
• If you do not fully understand these
instrucons, contact your Penko
representave for claricaon.
• Pay careful aenon to all warnings,
cauons, and instrucons marked on and
supplied with the product.
• Inform and educate your personnel about
the correct installaon, operaon, and
maintenance procedures for this product.
• Install your equipment as specied in the
installaon instrucons of the appropriate
Instrucon Manual and as per applicable
local and naonal codes. Connect all
products to the proper electrical sources.
• To ensure correct performance, use quali-
ed personnel to install, operate, update,
program, and maintain the product.
• When replacement parts are required,
ensure that qualied technicians use repla-
cement parts specied by Penko. Unauthori-
zed components and procedures can aect
the product's performance and may aect
the connued safe operaon of your
processes. The use of non-specied ‘look-
alike’ substuon parts may result in the
risk of re, electrical hazards, or improper
operaon.
• Ensure that all equipment doors are closed
and protecve covers are in place, except
when maintenance is being performed by
qualied persons, to prevent electrical
shock and personal injury.

1020 Indicator
WARNING
ELECTRICAL SHOCK HAZARD
Installing cable connecons and servicing this instrument require access to shock hazard
level voltages which can cause death or serious injury.
Disconnect separate or external power sources to relay contacts before commencing any
maintenance.
The electrical installaon must be carried out in accordance with CE direcons and/or any
other applicable naonal or local codes.
Unused cable conduit entries must be securely sealed by non-ammable blanking plates or
blind grommets to ensure complete enclosure integrity in compliance with personal safety
and environmental protecon requirements.
To ensure safety and correct performance this instrument must be connected to a
properly grounded, three-wire power source.
Proper relay use and conguraon is the responsibility of the user.
Do not operate this instrument without the front cover being secured. Refer any
installaon, operaon or servicing issues to qualied personnel.
WWW.PENKO.COM
Penko is an ETC Company
e-mail: [email protected]
3

1020 Indicator
TABLE OF CONTENT
Chapter Page
1. Indication of display 6
2. Screen Elements 6
3. Explanation of front keys 7
3. Load cell / power connection 8
4. First use of Indicator 15
4.1. Weigher Setting 15
4.2. Calibration Setting 20
5. Menu Setting 23
5.1. System Settings 23
5.1.1. Port Setup 24
5.1.2. Indicator Setup 31
5.1.3. In/Outputs 55
5.1.4. Password 62
5.1.5. Screen Setup 65
5.1.6. Set Clock 70
5.1.7. Printer 71
5.1.8. System Recall 76
5.1.9. Software Update 79
5.2. Totals 82
5.3. Info 83
5.4. Certified Info 85
5.5. Event Log 87
5.6. Alibi memory 91
6. Software Tool 96
7. Dimensions 97
8. Error Codes 99
8.1. Weigher Error Codes 100
4

1020 Indicator
TABLE OF CONTENT
Chapter Page
10. Profibus Protocol Description 101
11. Standard Factory Settings 102
Appendix I 103
Appendix II 104
Appendix III 105
5

1020 Indicator
1. Indication of Display
1. Zero active
2. Tare active
3. Weigher stable
4. Inputs
5. Value
6. Range active
7. Bargraph
8. Outputs
1
2
4
3
5
6
8
7
2. Screen Elements
1. Active keys
2. Menu level
3. Traceable Acces Code
4. Calibration Code
2
1
3
4
6

1020 Indicator
2. Explanation of front keys
Tare
Check the NET sign (See page 5, Indication of Display, number 2) if
there is a tare active.
Press key to set tare. Press key again to reset tare.
Preset Tare
Check the NET sign (See page 5, Indication of Display, number 2) if
there is a tare active.
Press key to set preset tare. Press Tare key to reset preset tare.
Enter
Press key >2s to enter main menu.
Zero
Press key <2s to create a new zero level.
Press key >2s to reset zero level to the original zero level.
Print/Escape
If in a menu, press key to go to the previous menu. If on main screen,
use for printing the value. Press key <2s to print the actual value. Press
key >2s to print batch total.
Up or increase value by 1
Left or change position of cursor
Down or decrease value by 1
Right or change position of cursor
7

1020 Indicator
3. Load cell / power connection
PENKO 1020 Basic Inputs
8
This product is intended to be supplied
by a Class 2 or Limited Power Source,
rate 18 - 32 Vdc, 0.4A@24Vdc.
Power connection
Supply 18 - 32 Vdc
Load cell connection
Analogue output mA
Option
OutputsOutputs
Inputs
The power cable
must be looped
through a ferrite
core 3 mes.
Recommended
ferrite core:
Würth Elektronik
7427154

1020 Indicator
3. Load cell / power connection -continue-
PENKO 1020 Profibus
9
Power connection
Supply 18 - 32 Vdc
Load cell connection
Analogue output mA
Option
Outputs
This product is intended to be supplied
by a Class 2 or Limited Power Source,
rate 18 - 32 Vdc, 0.4A@24Vdc.
Inputs
The power cable
must be looped
through a ferrite
core 3 mes.
Recommended
ferrite core:
Würth Elektronik
7427154

1020 Indicator
3. Load cell / power connection
PENKO 1020 Profibus
PIN No. Symbol Name Name
1: SHIELD SHIELD Protecve Ground
2: RP Reserved for Power
3: B/B Rxd/TxD-PReceive/Transmit-Data-P
4: CNTR-PControl-P
5: C/C DGND Data Ground
6: VP Voltage plus
7: RP Reserved for Power
8: A/A RxD/Txd-NReceive/Transmit-Data-N
9: CNTR-NControl-N
Profibus connection wiring
10
Andere Handbücher für 1020 Series
2
Inhaltsverzeichnis
Beliebte Touchscreen Handbücher anderer Marken

IBASE Technology
IBASE Technology ASTUT-152-RE1S Bedienungsanleitung

YASKAWA
YASKAWA TP 610C Bedienungsanleitung

B&R
B&R Power Panel C Series Bedienungsanleitung

Beijer Electronics
Beijer Electronics X2 control Bedienungsanleitung

AXIOMTEK
AXIOMTEK GOT321W-521 Bedienungsanleitung

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Bedienungsanleitung