Pepperl+Fuchs IDENT-I system P IPT FP Series Bedienungsanleitung

IPT*-FP with U-P6-B5-V
Read/write station with
INTERBUS interface
FACTORY AUTOMATION
MANUAL

2
IPT*-FP WITH U-P6-B5-V
1 Introduction..................................................................4
2 Declaration of conformity ...........................................5
2.1 CE conformity ........................................................................................... 5
3 Safety............................................................................6
3.1 Symbols relevant to safety ...................................................................... 6
3.2 Intended use.............................................................................................. 6
3.3 General safety instructions...................................................................... 6
3.4 Operational reliability and monitoring .................................................... 7
4 Product description.....................................................8
4.1 Product family ........................................................................................... 9
4.1.1 Code/data carrier ........................................................................................ 9
4.2 Range of application ...............................................................................10
4.3 Delivery package......................................................................................10
4.4 Device characteristics.............................................................................10
4.5 Display and controls ...............................................................................11
4.6 Diagnostic LEDs ......................................................................................11
4.7 Interfaces and connections ................................................................... 12
5 Installation..................................................................13
5.1 Storage and transport ............................................................................ 13
5.2 Unpacking ............................................................................................... 13
5.3 EMC screening........................................................................................ 13
5.4 Device connection .................................................................................. 14
5.4.1 Voltage supply .......................................................................................... 14
5.4.2 Earth connection....................................................................................... 15
5.4.3 Ring termination........................................................................................ 15
5.4.4 Cable lengths............................................................................................ 16
5.4.5 Cable ........................................................................................................ 16
5.4.6 Transfer rate changeover.......................................................................... 16

3
IPT*-FP WITH U-P6-B5-V
6 Commissioning ......................................................... 17
6.1 Installation check ....................................................................................17
6.2 Preliminary considerations ....................................................................18
6.3 Self test ....................................................................................................18
7 Operation on the INTERBUS.................................... 19
7.1 General information on INTERBUS........................................................19
7.2 Outline of the commands and data on the INTERBUS ........................19
7.3 General command information ..............................................................19
7.3.1 Software information .................................................................................19
7.3.2 Command overview...................................................................................21
7.4 System commands..................................................................................23
7.5 Read/write commands ............................................................................26
7.5.1 Read data..................................................................................................26
7.5.2 Write data ..................................................................................................30
7.6 Read only code ........................................................................................34
7.7 Special command modes .......................................................................38
7.7.1 IPC03 configuration ...................................................................................38
7.7.2 Password mode with IPC03 ......................................................................48
7.7.3 Write fixed code IPC10 ..............................................................................51
7.8 Legend......................................................................................................55
7.9 Error/Status messages ...........................................................................56
8 Technical specifications .......................................... 57
8.1 Read/write station IPT*-FP......................................................................57
8.2 Read/write distances IPT*-FP.................................................................58
8.3 U-P6-B5-V lower section .........................................................................59

205842 2009-03
4
IPT*-FP WITH U-P6-B5-V
Introduction
1 Introduction
Congratulations
You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs develops,
produces and distributes electronic sensors and interface modules for the market of
automation technology on a worldwide scale.
Before you install this device and put it into operation, please read the operating instructions
thoroughly. The instructions and notes contained in this operating manual will guide you step-
by-step through the installation and commissioning to ensure the trouble-free usage of this
product. This is useful to you, because with this you:
• support the safe operation of the device
• can utilize the device’s entire range of functions
• reduce faulty operation and the associated errors
• reduce costs from downtime and incidental repairs
• increase the effectiveness and operating efficiency of your plant.
Store this operating manual somewhere safe in order to have it available for future work on the
device.
Directly after opening the packaging, please ensure that the device is intact and that the
package is complete.
Symbols used
The following symbols are used in this manual:
Handling instructions
You will find handling instructions beside this symbol
Contact
If you have any questions about the device, its functions, or accessories, please contact us at:
Pepperl+Fuchs GmbH
Lilienthalstraße 200
68307 Mannheim
Telephone: +49 621 776-4411
Fax: +49 621 776-274411
E-Mail: fa-info@pepperl-fuchs.com
Note!
This symbol draws your attention to important information.

IPT*-FP WITH U-P6-B5-V
Declaration of conformity
205842 2009-03
5
2 Declaration of conformity
2.1 CE conformity
This product was developed and manufactured under observance of the applicable European
standards and guidelines.
Note!
A declaration of conformity can be requested from the manufacturer.

205842 2009-03
6
IPT*-FP WITH U-P6-B5-V
Safety
3 Safety
3.1 Symbols relevant to safety
3.2 Intended use
Together, the devices IPT*-FP and U-P6-B5-V of the inductive identification system IDENT-I
System P comprise a read/write station..
Always operate the device as described in these instructions to ensure that the device and
connected systems function correctly. The protection of operating personnel and plant is only
guaranteed if the device is operated in accordance with its intended use.
3.3 General safety instructions
Only instructed specialist staff may operate the device in accordance with the operating
manual.
Independent interventions and separate modifications are dangerous and will void the warranty
and exclude the manufacturer from any liability. If serious faults occur, stop using the device.
Secure the device against inadvertent operation. In the event of repairs, send the device to
Pepperl+Fuchs.
The connection of the device and maintenance work when live may only be carried out by a
qualified electrical specialist.
The operating company bears responsibility for observing locally applicable safety regulations.
Store the not used device in the original packaging. This offers the device optimal protection
against impact and moisture.
Danger!
This symbol indicates a warning about a possible danger.
In the event the warning is ignored, the consequences may range from personal injury to death.
Warning!
This symbol indicates a warning about a possible fault or danger.
In the event the warning is ignored, the consequences may course personal injury or heaviest
property damage.
Caution!
This symbol warns of a possible fault.
Failure to observe the instructions given in this warning may result in the devices and any
connected facilities or systems develop a fault or fail completely.
Note!
Electronic waste is hazardous waste. Observe local disposal regulations.

IPT*-FP WITH U-P6-B5-V
Safety
205842 2009-03
7
3.4 Operational reliability and monitoring
The devices IPT*-FP and U-P6-B5-V of the inductive identification system IDENT-I system P
operate on a microprocessor level. Device status is reported via LEDs on the front side on the
IPT*-FP read station and in the U-P6-B5-V lower section terminal compartment.
In addition, the INTERBUS functionality can be tested by querying the status information or via
specific commands to test the device. Device error or the failure of a read/write station, for
example, can be recognized and reported by the INTERBUS master in this way.

205842 2009-03
8
IPT*-FP WITH U-P6-B5-V
Product description
4 Product description
The brand name IDENT-I System P represents a complete identification system. The read/write
station consists of the read/write head IPT*-FP (standard version: IPT1-FP) and the lower
section U-P6-B5-V with INTERBUS interface. With the use of 125 kHz technology, the system
is extensively open for the implementation of other components.

IPT*-FP WITH U-P6-B5-V
Product description
205842 2009-03
9
4.1 Product family
The inductive identification system IDENT-I system P from Pepperl+Fuchs offers various
possible combinations of individual components.
4.1.1 Code/data carrier
A wide assortment of designs is available for the inductive 125 kHz code and data carriers.
Data carriers are available for temperatures up to 300 °C (max. 5 min) in chemical-resistant
housings for installation in metal and in protection class IP68/IP69K. IPC02-... code carriers
offer 40-bit fixcode. IPC03-... data carriers have 928 bits of freely programmable memory and a
non-variable fixcode of 32 bits. The storage area of the IPC03-…can be protected against
unauthorized read and write. 40-bit fixcodes that can be freely determined can be generated
with IPC11-... code carriers. These fixcodes can be generated one time permanently or they
can be modifiable.
1Read/write station
2Lower sections
3Code/data carrier
2
1
3
Note!
Detailed information on the components of the identification system IDENT-I system P can be
found in the sensor systems 1 catalog.

205842 2009-03
10
IPT*-FP WITH U-P6-B5-V
Product description
4.2 Range of application
The system is suited for the following applications:
• Automation
• Material flow control in production
• Acquisition of operating data
• Access control
• Identification of e.g. storage vessels, pallets, work piece carriers, refuse containers, tanks,
containers, etc.
4.3 Delivery package
IPT*-FP contains:
• 1 Read/write head
• CD with documentation (incl. this manual)
U-P6-B5-V1contains:
• Lower section
• 1 cover
• 2 ring terminals
• 1 earthing screw
• 1 serrated lock washer
1 sticker
4.4 Device characteristics
The lower section U-P6-B5-V connects the read/write station with the INTERBUS installation
remote bus.
• Supply voltage with galvanic isolation
• Bus interfaces with functional isolation accordant with EN 50178.
• Installation field bus connection via M23 round connector
• Addressing by means of physical position of the station in the system
• Display LEDs (on the front of the read/write station IPT*-FP)
• Diagnostic LEDs
• The lower section operates as a passive node (Slave). It is therefore restricted to use on
the cyclically read process data channel. The device assigns 5 words to each 16 bits (10
bytes). The acyclically read parameter channel of the INTERBUS protocol is not assigned.
1The lower section must be ordered separately.