1General information.....................................................................................................3
2Technical specifications ..............................................................................................4
3Delivery set..................................................................................................................4
4Product description......................................................................................................5
4.1 Design ...................................................................................................................5
4.2 Operating principle ................................................................................................6
4.3 Data transmitting via Wiegand interface................................................................7
5Configuration...............................................................................................................8
5.1 Operation of reader in RS-485 mode.....................................................................8
5.1.1 Selection of reader number............................................................................8
5.1.2 Indication........................................................................................................9
5.2 Operation of reader in Wiegand mode.................................................................10
5.2.1 Indication setting ..........................................................................................10
5.2.2 Changing the format of output data..............................................................10
6Safety requirements ..................................................................................................11
6.1 Safe installation...................................................................................................11
6.2 Safe operation.....................................................................................................11
7Installation procedure................................................................................................12
7.1 Features of installation ........................................................................................12
7.2 Tools and equipment required for installation......................................................12
7.3 Required cables...................................................................................................12
7.4 Assembly sequence ............................................................................................13
8Troubleshooting.........................................................................................................15
9Perco warranty..........................................................................................................15

IRP-01 Reader Post
3
1 GENERAL INFORMATION
IRP-01 reader post is designed for reading and interpretation of proximity card identifier
and for transferring of identifier to ACS controller. The reader post is made in the form of
stainless steel cylindrical post equipped with proximity card reader and LCD indicating
operation modes of ACS controller.
IRP-01 reader post is designed as an up-market model to fit the highest requirements for
design and comfort (governmental offices, banks, administrative buildings, sport centers,
airports, etc.).
The reader post, with regard to resistance to environmental exposure, conforms to
category NF4 (operation in premises with climate control) according to GOST 15150-69.
Operation of the reader is allowed at ambient air temperature from +1°Сto +40°Сand at
relative air humidity of up to 80% at +25°С.
The reader has the marking on the inner side of the housing. The marking contains the
product name, the model abbreviation, the date of manufacture, the serial number.
The reader is packed in a cardboard box that protects it from being damaged during
transportation and storage.
Overall dimensions of the box (L × W × H)............................................1120×140×130, mm
Weight of the box................................................................................................... max. 7 kg
The reader in the original package should be transported in closed freight containers or
other closed type cargo transport units.
Storage of the reader is allowed in dry indoor facilities at the ambient air temperature from
+1°Сto +40°Сand relative air humidity of up to 80% at +25°С.
During storage and transportation the boxes can be stacked no more than 5 layers high.
After transportation or storage at temperatures below zero or at high air humidity, prior to
installation the reader must be kept in the original package for no less than 24 hours
indoors under normal climate conditions prior to installation.
Due to continuous improvement of products the Manufacturer reserves the right to modify,
without notice, the product design not aggravating its technical specifications.

Certificate & Operation Manual
4
2 TECHNICAL SPECIFICATIONS
Rated operating voltage1
Operating voltage limits .................................................................................. 10.8–14VDC
......................................................................................... 12VDC
Consumption current ...................................................................................... max. 150 mA
Power consumption .............................................................................................. max. 2 W
Card reading distance at the rated operating voltage for different card types:
HID ProxCard II cards ................................................................................. min. 6 cm
EM-Marin cards ........................................................................................... min. 7 cm
Controller connection interface2
Distance between reader and controller ............................................................. max. 40 m
............................................................... RS-485, Wiegand
Reader post weight .............................................................................................. max. 5 kg
Reader post dimensions (see Fig. 1) .................................................... 1025×107×107 mm
Mean lifetime ........................................................................................................... 8 years
Electric shock protection class ........................................... III under GOST R IEC 335-1-94
3 DELIVERY SET
Reader post ....................................................................................................................... 1
Mounting base ................................................................................................................... 1
S2 allen key ....................................................................................................................... 1
Package ............................................................................................................................. 1
Certificate and Operation Manual ...................................................................................... 1
Additional mounting tools:
The following equipment can be supplied optionally on request:
PFG IR 8-20 anchor («SORMAT», Finland) ...................................................................... 4
1As a power supply it is recommended to use DC source with linear voltage stabilization and
output pulsation amplitude max. 50 mV.
2Depends on position of switch №1 SA1.

IRP-01 Reader Post
5
4 PRODUCT DESCRIPTION
4.1 Design
Reader post consists of stainless steel tube with reader board and LCD. Delivery set also
contains mounting base that the reader post housing is attached to.
The reader is equipped with integrated sound indicator. Code reading is confirmed by a
short sound signal.
Figure 1. IRP-01 overall view and dimensions

Certificate & Operation Manual
6
The board of the reader is shown on Fig. 2.
Figure 2. The board of the reader
The board contains:
ХТ1 –connectors for power cables.
ХТ3 – connector for connection via RS-485 interface.
ХТ4and ХТ5 –connectors for connection via Wiegand interface.
ХР5– “disconnection of EOL resistor” connector for RS-485.
SA1 – DIP-switch for reader setting.
4.2 Operating principle
Readers provide code reading from Proximity identifiers with operation frequency 125 kHz
(hereinafter – the identifier) produced by HID Corporation, type: ProxCard II, ISOProx II
(standard formats HID: 26 bit (H10301), 37 bit (H10302, H10304)), and also IL-05ELR
and ЕM4100/4102 identifiers produced by EM-Microelectronic-Marin SA.
Code reading is performed when the identifier is presented to the reader. Maximum
operating distance between the identifier and the reader depends on the type of the
identifier. The identifier can be placed inside pocket, wallet or any other radio transparent
container (cover).
Figure 3. Reader operation
When switched on the reader radiates low frequency (125 kHz) electromagnetic field.
Caught in this field the identifier is activated and starts transmitting individual encoded
signal that is received by the reader.

IRP-01 Reader Post
7
Reader transforms the received signal in accordance with an external device interface and
sends it to controller of external device via RS-485 or Wiegand interfaces.
Data is transmitted to the external controller at one time, asynchronously, at the moment of
first positive signal receipt from identifier. Repeated data transfer is possible not earlier
than 200 ms after identifier leaves stable reception zone.
4.3 Data transmitting via Wiegand interface
Two wires are used for transmission: «data 0» and «data 1». When logic level «0» occurs
on one of the wires it signals the presence of bit with appropriate value in coded mark.
Time response characteristics of output data format:
Duration of data pulse................................................................................... 100 mcs
Pulse-time...........................................................................................................1 ms
All bytes are transmitted with high-order bits forward.
Figure 4. Formation of output reader signals and their diagrams
The length of the coded mark depends on the output data format set at assembly and can
be either fixed or specified by data dimension received from identifier.
Following rules are applied when there is difference between coded mark received from
identifier and the output coded mark:
- If the input coded mark from identifier is longer than output mark the excessive high-
order bits are truncated.
- If the input coded mark from identifier is shorter than output mark the missing high-
order bits are padded with zeros.
The structure of coded mark and order of parities in it for fixed length formats are
presented in the following Figures:
•The identifier encoded signal includes the even number of bits (N/2 – integer):

Certificate & Operation Manual
8
•The identifier encoded signal includes the uneven number of bits (N/2 – non
integer):
The structure of output coded mark in Wiegand 26 (H10301) format is presented in Figure:
1 – Control bit (corresponds with the even parity for the next 12 bit data)
2 – Byte code
3 – High-order byte of card number
4 – Low-order byte of card number
5 – Control bit (corresponds with the odd parity for the previous 12 bit data).
5 CONFIGURATION
The interface of the reader is chosen with the use of switch №1 of DIP-switch SA1, located
on the board of the reader (see Fig. 2):
•ON – connection to RS-485 interface,
•OFF – connection Wiegand interface.
5.1 Operation of reader in RS-485 mode
To operate the reader in RS-485 mode the switch №1 of DIP-switch SA1, located on the
board of the reader (see Fig. 2), shall be set in ON position. When the reader is connected
via RS-485 interface, it can be used as an external reader for PERCo Web controllers.
5.1.1 Selection of reader number
When readers are connected to RS-485 interface, they need to have different numbers
(switch 2) to determine the direction of passage. Binding of reader number to passage
direction is made by computer software.
The number is selected with the use of switch 2 of DIP-switch SA1, located on the board of
controller (see Fig. 2), in such case switch 1 shall be set in ON position. Number of reader
is determined according to Table 1.
Table 1. Setting of reader number on DIP-switch SA1
Reader number
Switch
1
2
Reader 1
ON
ON
Reader 2
ON
OFF

IRP-01 Reader Post
9
5.1.2 Indication
When operated with PERCo Web controllers, LCD of the reader show the following
indication of controller operation modes:
“Control” mode indication – general
background and an appearing hand with
a card, showing that it is necessary to
present a card
“Open” mode indication, and also the
response to the presentation of
authorized card – moving green arrow.
“Closed” mode indication, and also the
response to the presentation of non-
authorized card –
STOP inscription with changing color of
letters.
Indication of waiting for verification –
hourglass.
Inhaltsverzeichnis
Andere PERCo Kartenleser Handbücher

PERCo
PERCo IC-03.1 Montage- und Bedienungsanleitung

PERCo
PERCo RP-15.2 Bedienungsanleitung

PERCo
PERCo IR-10 Bedienungsanleitung

PERCo
PERCo IC02.1 Montage- und Bedienungsanleitung

PERCo
PERCo IR-04.1 Montage- und Bedienungsanleitung

PERCo
PERCo IC-05 Montage- und Bedienungsanleitung

PERCo
PERCo IR-03.1 Montage- und Bedienungsanleitung
Beliebte Kartenleser Handbücher anderer Marken

Rosslare
Rosslare DR-6255 Bedienungsanleitung

Lindy
Lindy 51541 Bedienungsanleitung

Diapro T?bbi Ürünler
Diapro T?bbi Ürünler Across System Bedienungsanleitung

Johnson Controls
Johnson Controls Kantech tyco ioSmart Bedienungsanleitung

ACS
ACS ACR122L Bedienungsanleitung

Secukey
Secukey S2-MF Bedienungsanleitung