Politec ADEBUS Bedienungsanleitung

PRODUCT
ADEBUS &
GAPID EXPLORER
ADEBUS &
GAPID EXPLORER
Product code ADEBUS & GAPID
EXPLORER
MONITORING CONTROL UNIT
INSTALLATION AND WIRING MANUAL VERSION 1.8
1

Table of contents
2
ADEBUS & GAPID EXPLORER
1.Introduction…………………………………………………………………………………………………………………………………...3
2.Product description …………………………………………………………………………………………….………………….. 3
3.General warnings……………………………………………………………………………………………………………………….…. 4
3.1 Additional warnings for devices powered by mains voltage
3.2 Installation warnings
4.List of main components ………………………………………………………………………………………………………………..5
4.1 The control unit
4.2 Gapid SR
5.Description of the boards ……………………………………………………………………………………………………………… 7
5.1 ALPO1B - Power supply board
5.2 ADEBUS G - Adebus motherboard
5.3 ADEBUS ESP - Expansion of 16 relay outputs for Adebus
5.4 ADEBUS INTERFACE
6.Preparation for installation …………………………………....…………………………………………..………………………...10
6.1 Preparing the components before installation
6.2 It is advisable to carry out
7.Sensor mounting …………………………………………………………….……………………………………………………………...11
8.Relay output connections.…………………………………....…………………………………………………………………………13
9.Gapid SR sensor …………………………….…………………………………………………………………………..……….......14
10.Installation method ………………………………………………....……………………………………………………………….….15
11.Connection of sensors to the control unit ................................................................……………………... 17
12.First access to the Adebus G board via IP address 192.168.1.222 ……………………………………….....……..18
13.Gapid Explorer installation …………………………………………………….………………………………………………........19
14.First start-up ………………………………………………………………………………………………….……………………...........21
14.1 Main screen
14.2 Working path
14.3 Site creation
14.4 Site configuration
14.5 Single sensor configuration
14.6 Operating condition
15.Configuration and management via web. …………………………………..………….………………………….….….... 30
16.Archive ............................................................................................................................................... 31
16.1 Description of events
17.Settings………………………………………………………………………………………………………………………………………….32
17.1 Enable pop up
17.2 Reset Adebus G board
17.3 Advanced configurations - Group
17.4 Advanced configurations - Gapid SR
17.5 Advanced configurations - System configuration
17.6 Advanced configurations - Send group structure
17.7 Advanced configurations - Logout
18.Gapid SR Technical specifications……………………………………………………………………………………………..... 42
18.Adebus Gapid Technical specifications……………………………………………………………………………………..... 43
20.Product disposal.…………………………………………………………………………………………………………………..….….44
POLITEC | INSTALLATION MANUAL - VER.1.8

1.Introduction
3
ADEBUS & GAPID EXPLORER POLITEC | INSTALLATION MANUAL - VER.1.8
Congratulations on having purchased the Politec monitoring control unit.This appliance
guarantees long-lasting and reliable operation if installed correctly.For correct and effective use,
it is necessary to read this instruction manual carefully.
The sensor and the monitoring control unit have been designed to detect intrusions
and activate the alarm; it is not a device that prevents intrusion.Politec is not
responsible for damage, injury or loss caused by accidents, theft, force majeure
(including momentary lightning-induced overcurrent), abuse, improper or incorrect
use, faulty installation or inadequate maintenance.
2. Product description
The Adebus & Gapid Explorer is a monitoring control unit for the management of up to 128
sensors divided arbitrarily into 2 branches (expandable) using both the serial ports Com0 and
Com1.Adebus Gapid manages, supervises and configures every single Gapid SR (or groups)
combined with Adebus hardware boards, set up with the appropriate firmware, reachable
through a TCP/IP connection.
This system is ideal for sensor management for perimeter protection of large areas.
It is equipped with an internal algorithm system that allows multiple sensors to be installed on
the same site in different applications and realtime management of every single vibration.The
main features of this system are as follows:
•Detection of each alarm of the individual group or sensor.
•Ability to interact on all system parameters, to know and change the status of the sensors
(single or group);
•Each sensor, single or in group, can be configured and verified in real time: all operations can
be performed locally or remotely via WEB;
•Store and download up to 32000 events on aPC.
Warnings
Mounting, installation of the barrier and connection to the mains must be carried out
by expert and qualified personnel, in compliance with rules and regulations applicable
to electrical systems.

3.General warnings
4
ADEBUS & GAPID EXPLORER
This installation manual contains important information regarding safety for installation: it is
necessary to read all the instructions before proceeding with the installation.
Keep this manual for future use.
•If you have any questions or doubts during installation, do not carry out any operations and contact
the support service.
•Use of these products for purposes other than those specified in these instructions is prohibited.
•You must not make any change to the components of the product unless stated in the manual in
order not to void the warranty; such operations can only lead to malfunctions; Politec assumes no
liability for malfunctions or damage due to modified products.
•Depending on the specific situation of use, check for the need for additional devices: detectors or
signalling devices.
•During installation, mounting and use of the product, make sure no foreign objects (solids, metals
or liquids) are able to penetrate inside the open devices.
•Manufacturer's liability:Politec assumes no liability for failures resulting from incorrect installation;
lack of maintenance, incorrect assembly or use.
•Politec is also not liable for incorrect or incomplete operation of the product or failure to detect
intrusion.
•Warranty (summary of conditions):Politec guarantees its products for a period of 2 years from the
production date.The warranty is applied to those purchasing directly from Politec; there is no
warranty for the end user who, in the event of breakdowns or faults, must contact the installer or
dealer.
•The warranty excludes aesthetic parts as well as parts subject to normal wear and parts subject to
normal consumption such as batteries and accumulators.
3.1 Additional warnings for devices powered by mains voltage
This manual is intended only for technical personnel qualified to install such devices.
•Assessing the hazards that may occur during installation and use of the system, in order to achieve
complete safety, it is necessary that installation takes place in full compliance with applicable laws,
methods, rules and regulations.
•Before accessing the internal terminals of the product, it is necessary to disconnect all the power
circuits.
•If automatic circuit breakers or fuses trip, before resetting them it is necessary to identify the fault
and repair it.
3.2 Installation warnings
•Check that all the material to be used is in excellent condition and suitable for use.
•Before proceeding with the installation, check the environmental class of the products in the
"technical specifications" chapter.
•Check, by comparing with the values shown in the paragraph "technical specifications".
•Do not place the system components close to heat sources as they could be damaged.
•Each product has its own operating principle: check the instructions for choosing the right position
in the respective instruction manual.
POLITEC | INSTALLATION MANUAL - VER.1.8

N
o.
COMPONENT CODE
DESCRIPTION
1
ADEBUS G
Adebus motherboard
2
ADEBUS ESP
Expansion of 16 relay
outputs
3
INTERFACE BOARD
4
TRASF
LAR22S
18/24 Vac transformer
5
ALPO1B
Power supply board
6
BATTERY (not
included)
17 Ah Battery
compartment
7
TAMPER
5
ADEBUS & GAPID EXPLORER
4.1 The control unit
The box contains the following components and accessories.
When opening the package, check that everything has been included.
POLITEC | INSTALLATION MANUAL - VER.1.8
4
6
1
3
7
4.Main components list
2
5

No
.
COMPONENT
1
Screw 3x7
2
Gapid SR cover
3
Serial CS board
4
Screw 3x20
5
Gapid SR container
6
Fixing plate
7
Cable
glands
6
ADEBUS & GAPID EXPLORER
4.2 Gapid SR
The box contains the following components and accessories.
When opening the package, check that everything has been included.
POLITEC | INSTALLATION MANUAL - VER.1.8
1
5
6
2 3
4
7

No
.
COMPONENT
1
18 Vac input
2
24 Vac input
3
24 Vac output
4
0
-13.8 Vdc outputs
5
Battery output
6
10 A fuse (24 Vac)
7
3 A fuse (12 Vac)
8
3 A fuse (battery)
5.Board Description
7
ADEBUS & GAPID EXPLORER
5.1 ALPO1B - Power supply board.
POLITEC | INSTALLATION MANUAL - VER.1.8
1
5
6
2
3
4
7
8

No
.
COMPONENT
1
Serial input line COM1
2
Serial input line COM2
3
0
-12 Vdc input
4
LAN port
5
Relay outputs block
6
Inputs
7
Relay expansion connection
8
ADEBUS & GAPID EXPLORER
5.2 ADEBUS G - Adebus motherboard.
POLITEC | INSTALLATION MANUAL - VER.1.8
16 3
7
2
4
5

No.
COMPONENT
1
0
-12 Vdc input
2
Relay outputs block 1
-8
3
Output connector to next
expansion board
4
Relay outputs block 9
-16
5
Input connector from CA 230
motherboard
6
Input connector from previous
expansion board
9
ADEBUS & GAPID EXPLORER
5.3 ADEBUS ESP - Expansion of 16 relay outputs for Adebus.
POLITEC | INSTALLATION MANUAL - VER.1.8
1
6
3
2
4
5
No
.
COMPONENT
1
Serial input line COM1
2
Serial input line COM2
3
Adebus connection
1
2
3
5.4 ADEBUS INTERFACE

6.Preparation for installation
10
ADEBUS & GAPID EXPLORER
6.1 Preparing the components before installation
Since the communication between the sensors and the monitoring unit takes place by wire, it is
advisable to firstly check that all the parts of the unit and sensors and their possible accessories are
present before beginning the installation.
6.2 It is advisable to carry out:
•The installation of the control panel application on a computer
•The installation of the sensors on the perimeters to be protected;
•checking sensor operation using software
•the permanent fixing of each sensor;
•the preparation and carrying out of electrical connections.
In order to avoid errors, operating and installation problems, it is advisable to proceed as follows:
a) Place all the products with the package open on a table;
b) Test the functioning of the sensors;
c) Arrange (without fixing) the sensors in the planned points;
d) Check that each sensor responds from the application;
e) Permanently fix the sensors.
Before proceeding with the installation, it is necessary to check the integrity of the product, the
adequacy of the model chosen and the suitability of the environment intended for installation:
• Check that all conditions of use fall within the "limits of use" and in the "Technical specifications of
the product".
• Check that the environment chosen for the installation is compatible with the total footprint of the
product.
• Check that the surface chosen for the installation of the product is solid so as to ensure stable fixing
and that it is adequately protected from possible impacts or atmospheric agents.
POLITEC | INSTALLATION MANUAL - VER.1.8
Andere Handbücher für ADEBUS
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Politec Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung