Table of contents
2
ADEBUS
1.Introduction…………………………………………………………………………………………........................................4
2.Product description…………………..………………………………………………………….………………………….…..4
3.General warnings…………………………………………………………………………………………………………………...….5
3.1 Additional warnings for devices powered by mains voltage
3.2 Installation warnings
4.List of main components………….………………………………………………………………………………………………..6
4.1 The control unit
5.Description of the boards ………………………………………………………………………………………………………… 7
5.1 ADEBUS SC - Adebus motherboard
5.2 ADEBUS ESP - Expansion board with 16 relay outputs for Adebus
5.3 ALPO2B
6.Preparation for installation ………………………………………………..…………………………………………………....10
6.1 Preparing the components before installation
6.2 It is advisable to carry out
7.Connections……………………………………………………………………………..…................................................12
7.1 Adebus internal connections
7.2 Barrier connections - Adebus
7.3 Examples of cable connections
8.Installation and first access - DEFAULT STATIC IP 192.168.1.222 …………..…………………………….....13
8.1 Access via Ethernet port
8.2 Factory settings
8.3 Adebus Explorer software installation and start-up
8.4 Main screen
8.5 Working Path
8.6 Site Creation
8.7 Configuration Mode
8.8 Address Setup
8.9 System Configuration
8.10 Adding or replacing barrier
8.11 Popup
9.Access to the columns - Adebus Explorer ……………………………....………..……………………………........ 18
9.1 Key
9.2 Column Detail
9.3 New Configuration
9.4 Input/Output Associations
9.5 Polarity
10.Events archive …………………....……………………………………………………..............................................21
POLITEC | INSTALLATION MANUAL - VER.2.1

Table of contents
3
ADEBUS
11.Appendix A - WEB page .………………………. ………………………. ………… ..… .. .22
11.1 Column Detail
11.2 Column Status
11.3 Output Configuration / Output Polarity
11.4 Network Configuration
12.Appendix B - configuration and barrier statuses ……………………………….… .. …… .24
12.1 Status
12.2 Analogue Values
12.3 Configuration
13.Appendix C - Special Input …………………………………………………… ..…………………………………………… ..... 27
13.1 Connection in barrier
13.2 Enabling and software status
13.3 Output configuration
14.Appendix D - Sectioning ….…………… .. ……………………………………………… ..... 29
14.1 Enabling in pairs - Sectioning
14.2 Area configuration - Sectioning
14.3 Software configuration - Sectioning
15.Technical characteristics …………….……………………………………………. ………… .30
16.Product disposal ………….………………. …………………………………. ……….….…. ..31
POLITEC | INSTALLATION MANUAL - VER.2.1

MAX 1 Km MAX 1 Km
MAX 32 Columns
1.Introduction
4
ADEBUS POLITEC | INSTALLATION MANUAL - VER.2.1
Congratulations on having purchased the Politec monitoring control unit.This appliance
guarantees long-lasting and reliable operation if installed correctly.For correct and effective use,
it is necessary to read this instruction manual carefully.
The barriers and the monitoring control unit have been designed to detect intrusions
and activate the alarm; it is not a device that prevents intrusion.Politec is not
responsible for damage, injury or loss caused by accidents, theft, force majeure
(including momentary lightning-induced overcurrent), abuse, improper or incorrect
use, faulty installation or inadequate maintenance.
2. Product description
ADEBUS is a monitoring control unit
for the management of up to 32
columns (MANA SMA, PARVIS MES
SMA, SANDOR PLUS SMA) divided
arbitrarily into 2 branches
(expandable) using both the serial
ports Com0 and Com1.Adebus
manages, supervises and configures
every individual column reachable
through a TCP/IP connection.
This system is ideal for managing
the perimeter protection of large
areas.
The main features of this system
are:
•Each column and beam can be
configured and verified in real
time: all operations can be
performed locally or remotely via
WEB;
•Configuration of each relay
output associated with any
event.
•Storing and downloading up to
32000 events on aPC.
Warnings
Mounting, installation of the barrier and connection to the mains must be carried out
by expert and qualified personnel, in compliance with rules and regulations applicable
to electrical systems.

3.General warnings
5
ADEBUS
This installation manual contains important information regarding safety for installation: it is
necessary to read all the instructions before proceeding with the installation.
Keep this manual for future use.
•If you have any questions or doubts during installation, do not carry out any operations and contact
the support service.
•Use of these products for purposes other than those specified in these instructions is prohibited.
•You must not make any change to the components of the product unless stated in the manual in
order not to void the warranty; such operations can only lead to malfunctions; Politec assumes no
liability for malfunctions or damage due to modified products.
•Depending on the specific situation of use, check for the need for additional devices: detectors or
signalling devices.
•During installation, mounting and use of the product, make sure no foreign objects (solids, metals
or liquids) are able to penetrate inside the open devices.
•Manufacturer's liability:Politec assumes no liability for failures resulting from incorrect installation;
lack of maintenance, incorrect assembly or use.
•Politec is also not liable for incorrect or incomplete operation of the product or failure to detect
intrusion.
•Warranty (summary of conditions):Politec guarantees its products for a period of 2 years from the
production date.The warranty is applied to those purchasing directly from Politec; there is no
warranty for the end user who, in the event of breakdowns or faults, must contact the installer or
dealer.
•The warranty excludes aesthetic parts as well as parts subject to normal wear and parts subject to
normal consumption such as batteries and accumulators.
3.1 Additional warnings for devices powered by mains voltage
This manual is intended only for technical personnel qualified to install such devices.
•Assessing the hazards that may occur during installation and use of the system, in order to achieve
complete safety, it is necessary that installation takes place in full compliance with applicable laws,
methods, rules and regulations.
•Before accessing the internal terminals of the product, it is necessary to disconnect all the power
circuits.
•If automatic circuit breakers or fuses trip, before resetting them it is necessary to identify the fault
and repair it.
3.2 Installation warnings
•Check that all the material to be used is in excellent condition and suitable for use.
•Before proceeding with the installation, check the environmental class of the products in the
"technical specifications" chapter.
•Check, by comparing with the values shown in the paragraph "technical specifications".
•Do not place the system components close to heat sources as they could be damaged.
•Each product has its own operating principle: check the instructions for choosing the right position
in the respective instruction manual.
POLITEC | INSTALLATION MANUAL - VER.2.1

N
o.
COMPONENT CODE
DESCRIPTION
1
ADEBUS
Adebus motherboard
2
ADEBUS ESP
Expansion board with 16
relay outputs
3
ADEBUS S2 BOARD
4
TRANSF
LAR22S
18/24 Vac transformer
5
ALPO2B
Power supply board
6
BATTERY (not
included)
17 Ah Battery
compartment
7
TAMPER
6
ADEBUS
4.1 The control unit
The box contains the following components and accessories.
When opening the package, check that everything has been included.
POLITEC | INSTALLATION MANUAL - VER.2.1
4
6
1
7
4.Main components list
2
5
3

No
.
COMPONENT
1
Serial input line COM0
2
Serial input line COM1
3
0
-12 Vdc input
4
LAN socket
5
Relay outputs block
6
Inputs
7
Relay expansion connection
8
RS485
Adebus S2 board
7
ADEBUS
5.1 ADEBUS SC - Adebus motherboard.
Control board, to which RS485 is connected for barriers, Adebus Esp and LAN port
POLITEC | INSTALLATION MANUAL - VER.2.1
1
3
5
2
4
6
7
8
5.Board Description

8
ADEBUS
5.2 ADEBUS ESP - Adebus ESP Relay board
Interface board between configured relay outputs and universal alarm control unit
POLITEC | INSTALLATION MANUAL - VER.2.1
4
5
3
1
2
No.
COMPONENT
1
0
-12 Vdc input
2
Relay outputs block 1
-8
3
Output connector to next
expansion board
4
Relay outputs block 9
-16
5
Input connector from CA 230
motherboard
6
Input connector from previous
expansion board
6

No
.
COMPONENT
1
18 Vac input
2
24 Vac input
3
24 Vac output
4
0
-13.8 Vdc outputs
5
Battery 12V
- 17Ah output
6
Signalling outputs
7
10 A fuse (24 Vac)
8
3 A fuse (12 Vac)
9
ADEBUS
5.3 ALPO2B - Power supply board.
POLITEC | INSTALLATION MANUAL - VER.2.1
1
5
6
3
4
7
8
2

6.Preparation for installation
10
ADEBUS
6.1 Preparing the components before installation
Since the communication between the barriers and the monitoring control unit takes place by wire, it
is advisable to firstly check that all the parts of the control unit and sensors and any accessories are
present before beginning the installation.
6.2 It is advisable to carry out in the following ORDER:
•The installation of the control unit application on a PC
•The assembly and wiring of the barriers on the perimeters to be protected;
•Alignment and functional verification of all barriers in the field without the use of software;
•Taking note of the serial numbers of the individual barriers;
•Site creation from Adebus Explorer software;
•Barrier addressing;
•System start-up via WEB page, System Configuration menu and individual column flags;
•Adebus output configuration;
•Barrier configuration;
Before proceeding with the installation, it is necessary to check the integrity of the product, the
adequacy of the model chosen and the suitability of the environment intended for installation:
• Check that all conditions of use fall within the "limits of use" and in the "Technical specifications of
the product".
• Check that the environment chosen for the installation is compatible with the total footprint of the
product.
• Check that the surface chosen for the installation of the product is solid so as to ensure stable fixing
and that it is adequately protected from possible impacts or atmospheric agents.
POLITEC | INSTALLATION MANUAL - VER.2.1
Andere Handbücher für ADEBUS
1
Inhaltsverzeichnis
Andere Politec Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung