Pond Boss 52712 Bedienungsanleitung

Item | Article | Artículo#
52712, 52710, 52713, 52714
Thank you for choosing pond boss®
BEFORE RETURNING TO STORE
Contact Customer Care:
1-888-755-6750
Merci d’avoir choisi pond boss®
AVANT DE RETOURNER AU MAGASIN
Contact Les Soins de Client:
1-888-755-6750
Gracias por elegir pond boss®
ANTES DE DEVOLVER AL MINORISTA
Contacte Atención al Cliente:
1-888-755-6750

TABLE OF CONTENTS
Warnings and Cautions.............................................4-6
Package Contents........................................................6
Preparation..................................................................7
Operation Instructions..................................................7
Pump Performance......................................................8
Maintenance................................................................9
Troubleshooting and Replacement Parts.................9-11
Limited Warranty..................................................12-13
English
Avertissements et précautions.............................14-15
Contenu de l’emballage.............................................16
Préparation................................................................17
Instructions d’utilisation.............................................17
Rendement de la pompe............................................18
Maintenance..............................................................19
Dépannage et pièces de rechange........................19-21
Garantie limitée....................................................22-23
Français
1
TABLE DES MATIÈRES

Advertencias y precauciones................................24-25
Contenido del paquete...............................................26
Preparación...............................................................26
Instrucciones de funcionamiento................................27
Rendimiento de la bomba..........................................28
Mantenimiento...........................................................29
Solución de problemas y piezas de repuesto.........29-31
Garantía limitada..................................................32-33
Español
2
TABLA DE CONTENIDO

VISIT WWW.THEPONDBOSS.NET FOR PRODUCT INFORMATION AND TIPS.
EN
4
Fountain Pumps
Questions, problems, missing parts?
1-888-755-6750
customercare@thepondboss.net
Monday - Friday
Visit thepondboss.net for a step by step guide and video on how to
clean your pump.
IMPORTANT SAFETY INFORMATION
Please read these instructions carefully prior to starting up the unit!
The water system on which the operation of this product is based requires
utmost care and maintenance, possibly also the use of chemicals, in order to
prevent and keep the occurrence of micro-organisms and harmful bacteria,
especially legionellae that are responsible for legionnaire’s disease, under
control. Non-observance of this information about correct maintenance and
care can entail the spreading of harmful bacteria. Due to the fact that for
decorative purposes, water nozzles distribute water in the air, water droplets
containing harmful bacteria can enter your lungs and cause life-threatening
diseases.
It is the responsibility of the owner of the water system and its attendant
units to ensure their maintenance and care in compliance with the laws,
directives and instructions laid down for this purpose. In order to avert harmful
contamination, we urgently recommend the user to ensure cleaning and care
of the water system and the water feature including the nozzle, and to take all
necessary measures to maintain the technical units, such as pumps, tubing,
WARNINGS AND CAUTIONS

PLEASE CALL CUSTOMER CARE BEFORE RETURNING ITEM TO STORE: 1-888-755-6750
EN
5
connectors, under-water lighting, and nozzles to keep them in functional order
in line with safety aspects. However, the maintenance and care obligation is
not limited to the technical products supplied, but encompasses the entire
system.
We also recommend the owner to keep records of the dates when
maintenance and care was carried out, and to document all water tests made
in conjunction with the water feature. The owner is solely responsible for
guaranteeing the safety of the water feature. Use or maintenance of the units
sold and the system are beyond GeoGlobal Partner’s influence. GeoGlobal
Partners can only be held liable for manufacturing faults of pond boss®units.
WARNING
• Risk of electrical shock. This pump is supplied with a grounding conductor
and grounding-type attachment plug. To reduce the risk of electric shock,
be certain that it is connected only to a properly grounded, grounding-type
receptacle.
• Do not exceed the voltage shown on the pump.
• Always disconnect pump from the power source before beginning any
maintenance or work on the pump.
• Inspect cord for damage before installation and/or maintenance. Replace
the entire pump assembly if damage is found.
• Do not remove the grounding pin from the power cord plug.
• To reduce the risk of electric shock, use only on portable, self-contained
fountains no larger than 5-ft in any dimension.
• Risk of electrical shock - This pump has not been investigated for use in
swimming pool or marine areas.
CAUTION
• This pump has been evaluated for use with fresh water only.
• Use a proper power source as indicated on the pump label.
• Keep the cord away from high temperatures or other heat sources.
• Do not pump heated liquids.
• Do not let the pump run dry. Pump must be completely submerged for

VISIT WWW.THEPONDBOSS.NET FOR PRODUCT INFORMATION AND TIPS.
EN
6
PACKAGE CONTENTS
Part Description Qty
APump 1
B3/8 in. ID Tubing Adapter (52714, 52712 ) 1
C1/2 in. ID Tubing Adapter (52710, 52714, 52712) 1
D3/4 in. ID Tubing Adapter (52710 only) 1
E1/2 in. ID Tubing Adapter (52713 only) 1
F5/8 in. ID Tubing Adapter (52713 only) 1
G3/4 in. ID Tubing Adapter (52713 only) 1
A
CBDGE F
proper operation and cooling.
• Operate in freshwater only. Avoid heavily chlorinated water and water with
high pH levels.
• Do not lift the pump by its power cord.

PLEASE CALL CUSTOMER CARE BEFORE RETURNING ITEM TO STORE: 1-888-755-6750
EN
7
PREPARATION
Before beginning assembly or operation of product, make sure all parts are
present. Compare parts with package contents list and diagram. If any part is
missing or damaged, do not attempt to assemble, install or operate the product.
Contact Customer Care for replacement parts.
• Estimated assembly time: 5 minutes.
• No tools required for assembly.
OPERATION INSTRUCTIONS
Step 2. Connect tubing to the outlet of
the pump with the appropriate adapter.
NOTE: Tubing not included.
Step 3.Place the pump into the water
and connect to a properly grounded
electrical outlet.
1
Step 1. Adjust the flow control to the
lowest setting. Once the pump has been
turned on (after step 3) you may adjust
the flow control to the preferred setting.
2
3

VISIT WWW.THEPONDBOSS.NET FOR PRODUCT INFORMATION AND TIPS.
EN
8
PUMP PERFORMANCE
52714
52712
Pump Specifications
Max Flow Rate
90 GPH at 0 ft. height
Max Pumping Height
2.8 ft. (0 GPH)
Power Consumption
5 watts / 0.06 amps
Pump Specifications
Max Flow Rate
150 GPH at 0 ft. height
Max Pumping Height
3.7 ft. (0 GPH)
Power Consumption
7 watts / 0.1 amps
Ideal pumping range
FLOW RATES (GPH)**
LIFT (feet)
7 100
6 175
5 95 235
4 145 290
3 45 190 350
2 40 79 230 410
1 74 120 275 470
0 90 150 320 525
52714 52712 52710 52713
PUMPS
52710
52713
Pump Specifications
Max Flow Rate
320 GPH at 0 ft. height
Max Pumping Height
6.2 ft. (0 GPH)
Power Consumption
23 watts / 0.4 amps
Pump Specifications
Max Flow Rate
525 GPH at 0 ft. height
Max Pumping Height
7.9 ft. (0 GPH)
Power Consumption
42 watts / 0.6 amps
**See P. 18 or 28 for metric data

PLEASE CALL CUSTOMER CARE BEFORE RETURNING ITEM TO STORE: 1-888-755-6750
EN
9
MAINTENANCE
Step 1. Before cleaning,
always disconnect the
pump from the power
source and remove the
pump cover.
Step 2. Remove the
impeller cover to expose
the impeller assembly.
Remove the impeller
assembly by gently pulling
on the impeller blades. The
impeller is held in place by
a magnet.
Step 3. Use a soft cloth or brush and warm water to clean the impeller and the
inside of the impeller housing.
Step 4. Reassemble all pump parts and place in water before reconnecting to
the power source.
Regular cleaning of the pump may be necessary depending upon the
environment which it is operated. Clean the pump when it is visibly soiled or
when a drop in performance is detected. Clean pump in 4 easy steps!
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
• Check to make sure the power cord is plugged in, the pump is getting power.
• Check the pump outlet and any tubing, fountains, spitters etc. for kinks or
obstructions.
1 2
3 4

VISIT WWW.THEPONDBOSS.NET FOR PRODUCT INFORMATION AND TIPS.
EN
10
For replacement parts, contact Customer Care, Monday - Friday:
1-888-755-6750 customercare@thepondboss.net
• Remove the front cover and/or pump cover, and impeller cover to expose the
impeller. Turn the impeller to ensure that it is not broken or jammed.
IF THE PERFORMANCE OF THE PUMP IS NOT SATISFACTORY OR THE
PUMP DOES NOT FLOW EVENLY:
• Check to make sure the pump is completely submerged in water.
• Check to make sure the impeller and the housing are clean.
• Adjust flow control.
For more information on product maintenance and maintenance
videos, visit www.thepondboss.net
REPLACEMENT PARTS
90 gallon per hour Pump
(#52714)
B3/8 in. ID Tubing Adapter
C1/2 in. ID Tubing Adapter
DFront cover wth flow control knob
EImpeller cover
FImpeller Assembly
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Sprachen:
Andere Pond Boss Wasserpumpe Handbücher
Beliebte Wasserpumpe Handbücher anderer Marken

Sykes AmeriPumps
Sykes AmeriPumps GP100M Fehlerbehebungshandbuch

DUROMAX
DUROMAX XP WX Series Bedienungsanleitung

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Bedienungsanleitung

Franklin Electric
Franklin Electric IPS Bedienungsanleitung

Xylem
Xylem e-1532 Series Bedienungsanleitung

Milton Roy