Powerware BestLink IPK-0319 Bedienungsanleitung

bestlink
SNMP/WEB Adapter
User’s Guide
For use with IPK-0318, IPK-0319, and IPK-0320
www.powerware.com

Requesting a Declaration of Conformity
Units that are labeled with a CE mark comply with the following harmonized standards and EU directives:
:
Harmonized Standards: EN 50091-1-1 and EN 50091-2; IEC 950 Second Edition, Amendments A1, A2, A3, and A4
:
EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits
93/68/EEC, Amending Directive 73/23/EEC
89/336/EEC, Council Directive relating to electromagnetic compatibility
92/31/EEC, Amending Directive 89/336/EEC relating to EMC
The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration
of Conformity, contact:
Powerware Corporation
Koskelontie 13
FIN-02920 Espoo
Finland
Phone: +358-9-452 661
Fax: +358-9-452 665 68
Class A EMC Statements
FCC Part 15
NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EN50091-2
Some configurations are classified under EN50091-2 as “Class-A UPS for Unrestricted Sales Distribution.” For these
configurations, the following applies:
WARNING This is a Class A-UPS Product. In a domestic environment, this product may cause radio interference, in which
case, the user may be required to take additional measures.
Powerware is a registered trademark and ConnectUPS, X-Slot, and BestDock are trademarks of Powerware Corporation.
Netscape is a trademark of Netscape Communications Corporation. Microsoft and Windows are registered trademarks of
Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark of The
Open Group. OpenView is a trademark of Hewlett-Packard Company. NetView is a registered trademark of International
Business Machines Corporation.
.
Copyright 2001 Powerware Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be
reproduced in any way without the express written approval of Powerware Corporation.

Important Notice
Please read this notice if you are using an external BestLink Adapter
with a Unity/I Three-Phase UPS
If you are using an external BestLink Adapter, part numbers IPK-0318 or IPK-0319, please contact the Help Desk (see
page 33) to receive a DB-9 to DB-25 adapter (INT-0012) at no charge.
Connect the DB-9 to DB-25 adapter (INT-0012) to the X003 port on the Unity/I Three-Phase communications interface
board. After you have completed the configuration of the BestLink Adapter using the interface cable labeled “PC,” move it
to the port on the BestLink Adapter labeled “UPS” and connect the opposite end to the DB-9 to DB-25 adapter. Reset the
BestLink Adapter to ensure that it properly establishes communication with the UPS.


i
BestLink SNMP/WEB Adapter User’s Guide :LTM-1343 B Draft 10/03/2001
TABLE OF CONTENTS
1 Introduction 1....................................................
System Application 2............................................................
2 Installation 3.....................................................
Installing the Internal BestLink Adapter 3..............................................
Installing the External BestLink Adapter 4..............................................
Configuration 6................................................................
Configuring the Adapter Locally 6.................................................
Configuring the Adapter Remotely 6...............................................
3 Local Configuration 7..............................................
Before You Start 7..............................................................
Connecting the BestLink SNMP/WEB Adapter 8.........................................
Configuring the Adapter 10.........................................................
Set the IP Address, Gateway Address and MIB System Group 12............................
Set SNMP/WEB Card Control Group 12..............................................
Set Write Access Managers 12...................................................
Set Trap Receivers 13..........................................................
Set IP Addresses of Primary and Secondary Date Server 13................................
UPS Event Actions 13..........................................................
Set UPS Information 13.........................................................
Set Superuser Name and Password 14..............................................
E-mail Notification 14..........................................................
Back to Main Menu 14.........................................................
4 Remote Configuration 15............................................
Add a Routing Condition in the PC 15..................................................
Running the Web Browser 16.......................................................
Setup Network Configuration 17.....................................................
5 UPS Power Management 19..........................................
UPS Management from a Web Browser 19.............................................
Becoming a Superuser 19.......................................................
Turning the UPS On and Off 20....................................................

Table of Contents
ii BestLink SNMP/WEB Adapter User’s Guide :LTM-1343 B Draft 10/03/2001
Forcing the UPS to Shut Down 20..................................................
Planning a Scheduled UPS Shutdown and Restart 21....................................
Configuring E-mail Notification 21.................................................
Performing a Manual UPS Battery Test 22............................................
Scheduling a UPS Battery Test 22..................................................
Viewing the UPS History Logs 23..................................................
Viewing the UPS Status with CheckUPS-like Applet 23...................................
UPS Management from an SNMP NMS 23.............................................
Viewing UPS Monitoring Parameters 24.............................................
Forcing the UPS to Shut Down 24..................................................
Receiving Event Traps 24........................................................
Automatic Shutdown of UPS-Protected Computers 25......................................
6 Appendix 27......................................................
Adapter Components 28...........................................................
LED Description 29............................................................
DIP Switch Description 29.......................................................
Pin Assignments 30..............................................................
Serial Cable Definition 31.......................................................
Upgrading the BestLink Adapter Firmware 32............................................
Service and Support 33...........................................................
Two-Year Limited Warranty (US and Canada Only) 34......................................
International Limited Warranty 35....................................................

1
BestLink SNMP/WEB Adapter User’s Guide :LTM-1343 B Draft 10/03/2001
CHAPTER 1
INTRODUCTION
The BestLink SNMP/WEB Adapter is a network adapter for your
uninterruptible power system (UPS) that provides both SNMP and HTTP
compatibility, as well as advanced communication with true RS-232.
The BestLink SNMP/WEB Adapter is available in two models: and internal
for UPSs with a BestDock slot and external for connection to the UPS serial
port. Both models can connect to a twisted-pair Ethernet (10baseT) network
using an RJ-45 connector.
SNMP-compatible network management software (user-supplied) may be
used to monitor the UPS in a method similar to that of other network devices.
Others may wish to use a web browser such as NetscapeZor Microsoft
9
Internet Explorer to monitor and manage the connected UPS.
The adapter also supports remote monitoring and shutdown from
UPS-protected computer systems. NetWatch client software for use with a
BestLink Adapter is supplied on the Invensys Software Suite CD or on the
web at www.powerware.com. Client software is available for
Windows
9
95/98/NT/2000, Novell
9
NetWare
9
and various versions of UNIX
9
These programs communicate through TCP/IP with the BestLink Adapter and
automatically shutdown the protected system during extended power outages.
In addition, the BestLink SNMP/WEB Adapter has the following features:
:Configuration from serial port, telnet, or HTTP web browser.
:Management from HTTP web browser or SNMP management software.
:Supports MIB_II and BestLink MIB (bestpwr2.mib) management
information bases.
:Firmware upgradable from a Windows utility via a network connection.
:Scheduling function to control UPS shutdowns and startups.
:History log files (data and events) for recording power problems.
:UPS status information available to registered NetWatch clients for
automatic shutdown of Windows 95/98/NT/2000, Novell NetWare, and
UNIX.
:E-mail notification of changes in the UPS status.
.

Introduction
2BestLink SNMP/WEB Adapter User’s Guide :LTM-1343 B Draft 10/03/2001
System Application
The following diagram shows how the BestLink Adapter can be used in a
network application.
Ethernet
Management
Station or
Terminal RS-232
UPS
BestLink Adapter
NMS Station
or
Web Browser
Power Line
NetWareUNIX
Windows
95/98/NT/2000
NetWatch Client NetWatch Client NetWatch Client
Figure 1. BestLink SNMP/WEB Adapter System Application Diagram

3
BestLink SNMP/WEB Adapter User’s Guide :LTM-1343 B Draft 10/03/2001
CHAPTER 2
INSTALLATION
Installing the Internal BestLink Adapter
CAUTION
Before installing or removing the BestLink SNMP/WEB Adapter, the UPS MUST be turned off.
Hot-swapping is prohibited.
To install the internal BestLink SNMP/WEB Adapter, perform the following
steps:
1. Remove the BestDock cover on the UPS rear panel. Retain the
screws.
2. Install one of the mounting plates on the BestLink Adapter according
to your UPS model. Use the supplied screw to secure the mounting
plate to the adapter.
Any one of the three tabs can be removed from the three-tab
mounting plate so that the adapter fits securely into the UPS slot.
3. To prevent electrostatic discharge (ESD), place one hand on a metal
surface such as the UPS rear panel.
Slide the BestLink Adapter into the open slot and secure with the
screws removed in Step 1 (see Figure 2).

Installation
4BestLink SNMP/WEB Adapter User’s Guide :LTM-1343 B Draft 10/03/2001
Set both DIP switches
to the 0(off) position
1
0
Slide the adapter into
the UPS BestDock
Figure 2. Installing the Internal BestLink Adapter
4. Set both DIP switches on the adapter to the 0(off) position.
5. Connect an active 10BaseT cable to the network connector on the
BestLink Adapter.
NOTE For an internal BestLink Adapter in a FERRUPS 0800, Axxium Pro, or Powerware 9170
UPS, you MUST change the Config BestDock parameter for that UPS to BestDock 1 or 2 as
applicable. Refer to the UPS user’s guide for detailed instructions on how to change the
parameter through the UPS front panel configuration menu.
6. Continue to “Configuration” on page 6.
Installing the External BestLink Adapter
To install the external BestLink SNMP/WEB Adapter, perform the following
steps:
1. Verify that the UPS is turned off.
2. Use the supplied serial cable labeled “UPS” to connect the UPS port
on the BestLink Adapter to the UPS communication port.
If connecting to a FERRUPS model with a DB-25S communication
port, you must also use the supplied DB-9 to DB-25 adapter labeled
INT-0013B.
3. Set both DIP switches on the adapter to the 0(off) position.