Pro Breeze PB-AC05 Bedienungsanleitung

Instruction manual
Mode d’emploi
Manuale di istruzioni
Bedienungsanleitung
Manual de instrucciones
Model PB-AC05
12000 BTU Portable Air Conditioner

02 | English
Portable Air Conditioner
Thank you for choosing to purchase a product from Pro Breeze. Please read the entire
THU\HSJHYLM\SS`WYPVY[VÄYZ[\ZLHUKRLLWPUHZHMLWSHJLMVYM\[\YLYLMLYLUJL
Safety Warning
• Use the appliance only as described
in this instruction manual.
• Check that the voltage of the main
circuit corresponds with the rating of
the appliance before operating.
• This appliance is suitable for indoor
use only.
• This appliance is not a toy. Never
leave unattended around children or
pets.
• This appliance can be used by
children aged from eight years above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and
understand the hazards involved.
• Children shall not play with the
appliance.
• Cleaning and user maintenance shall
not be made by children without
supervision.
• Keep the appliance and all parts out
of the reach of children.
• This appliance is intended for
domestic use only. It should not be
used for commercial purposes.
Contents Pg
Safety Warning 02
:WLJPÄJ0UMVYTH[PVU9LNHYKPUN9 9LMYPNLYHU[.HZ 04
*H\[PVUc:WLJPÄJH[PVUZ 05
Parts 06
Control Panel 07
Installation 08
Controls 10
Emptying the Water Tank 14
Connecting the Water Hose for Continuous Drainage 15
Cleaning | Storage | Safety Features 16-17
Disposal 18
Helpful Information

English | 03
• 7SHJL[OLHWWSPHUJLVUHÅH[HUK
dry surface. Keep it at least 50cm
away from surrounding walls and/or
objects.
• When moving the appliance ensure it
is kept in an upright position.
• When adjusting the louvres do so
gently so as not to cause damage.
• Ensure the power cord plug is
properly inserted into the power
socket before operating.
• Where there is the need to install a
continuous drainage hose ensure the
connection of the drainage hose is in
NVVKJVUKP[PVU^P[OV\[ÅL_\YL
• Do not cover the power cord.
• +VUV[PUZLY[ÄUNLYZVYVIQLJ[ZPU[V
the air inlet or air outlet. Be sure
to keep the air inlet and air outlet
unblocked.
• Do not operate the appliance with
wet hands.
• Do not leave the appliance
unattended whilst connected to the
power supply.
• Do not pull the power cord to stop
the appliance.
• Do not unplug the appliance until it
has been switched off.
• Do not modify the appliance or use
any accessories other than those
supplied.
• Do not place or use the appliance,
power cord, or any accessories in a
bathroom, wet, or damp place.
• Do not cover the appliance whilst in
use.
• Do not use pressurised containers
LNHLYVZVSJHUZVYV[OLYÅHTTHISL
substances near the appliance.
• Do not use the appliance near petrol,
ÅHTTHISLNHZLZV]LUZVYV[OLY
heating sources.
• Do not allow water or other liquids
to enter into the appliance or
contaminate electrical parts.
• Do not attempt to repair or adjust
any electrical or mechanical elements
in the appliance. Doing so may be
unsafe and will void your warranty.
• Do not operate the appliance if
there are signs of damage to the
appliance, power cord, or any of the
accessories.
• Do not wipe or wash the appliance
with chemical solvents. Prior to
cleaning ensure the appliance is
turned off and unplugged from the
power supply.
• Avoid placing the power cord in
areas where it can become a tripping
hazard.
• Avoid using extension cables as they
TH`V]LYOLH[HUKJH\ZLHÄYLYPZR
• Unplug the appliance and store in a
cool and dry place when not in use.
• Never place anything on top of the
appliance.

04 | English
Specific Information
Regarding R290
Refrigerant Gas
• The appliance must be installed, used
and stored in an area that is greater
than 13m2.
• ;OPZHWWSPHUJLJVU[HPUZNVM9
refrigerant gas.
• 9 PZHYLMYPNLYHU[NHZ[OH[
complies with the European directive
on the environment.
• Do not puncture any part of
refrigerant circuit.
• )LH^HYL9 YLMYPNLYHU[PZ
odourless and does not have the
odour normally associated with
natural gas and propane tanks.
• The appliance must be placed in an
area without any continuous sources
VMPNUP[PVUZ\JOHZVWLUÅHTLZNHZ
or electrical appliances in operation.
• Do not puncture and do not burn.
• If the appliance is installed, operated
or stored in a non-ventilated area, the
room must be designed to prevent
the accumulation of refrigerant leaks
YLZ\S[PUNPUHYPZRVMÄYLVYL_WSVZPVU
due to ignition of the refrigerant
caused by electric heaters, stoves, or
other sources of ignition.
• The appliance must be stored in
such a way as to prevent mechanical
failure.
• Individuals who operate or work on
the refrigerant circuit must have the
HWWYVWYPH[LJLY[PÄJH[PVUPZZ\LKI`HU
accredited organisation that ensures
competence in handling refrigerants
HJJVYKPUN[VHZWLJPÄJL]HS\H[PVU
recognised by associations in the
industry.
• Maintenance and repairs that require
[OLHZZPZ[HUJLVMV[OLYX\HSPÄLK
personnel must be performed under
the supervision of an individual
ZWLJPÄLKPU[OL\ZLVMÅHTTHISL
refrigerants.

English | 05
Caution
• Do not operate the appliance if the
room temperature is greater than 32°C
in cooling mode or lower than 5°C in
dehumidifying mode.
Specifications
• Size: 36cm x 43cm x 73cm
• 5L[>LPNO[! RN
• Input Voltage: 220V-240V~
• Frequency: 50Hz
• Cooling Capacity: 12000 BTU/H
• Heating Capacity: 12700 BTU/H
• 9LMYPNLYHU[!9 N
• ,ULYN`,MÄJPLUJ`*SHZZ-VY*VVSPUN!(
• ,ULYN`,MÄJPLUJ`*SHZZ-VY/LH[PUN!(
• 9H[LK*HWHJP[`-VY*VVSPUN!>
• 9H[LK*HWHJP[`-VY/LH[PUN!>
• 9H[LK0UW\[-VY*VVSPUN!>
• 9H[LK0UW\[-VY/LH[PUN!>
• 9H[LK*\YYLU[-VY*VVSPUN!(
• 9H[LK*\YYLU[-VY/LH[PUN!(
• ,,9-VY*VVSPUN!
• ,,9-VY/LH[PUN!
• 4VPZ[\YL9LTV]HS!3/
• Air Flow Volume: 480m3/H
• Applicable Area: 30m2
• 6WLYH[PUN;LTWLYH[\YL9HUNL!*
• Available Temperature Settings: 16-30°C
• 5VPZL3L]LSc/PNO!K)
• 5VPZL3L]LSc3V^!K)

06 | English
Parts
Front View
1. Control panel
2. Swinging louvre
3. Body
4. Wheels
Rear View
5. Body
6. 9LTV[LJVU[YVS
7. 9LTV[LJVU[YVSOVSKLY
8. ,]HWVYH[VYÄS[LYJV]LY
L]HWVYH[P]LÄS[LY
Handle
10. Handle
11. Power cord tidy
12. Continuous drainage cap /
continuous water outlet
13. 9HKPH[PUNÄS[LY
14. Heat exhaust hose connector
15. *VUKLUZLYÄS[LY
16. Wheels
17. Bottom drainage cap /
bottom water outlet
Accessories
18. 9LTV[LJVU[YVS
Circular heat exhaust hose connector
20. Heat exhaust hose
21. Heat exhaust hose short connector
22. Sliding window sealing board
assembly
23. Hinged window fabric sealing
assembly
24. Sealing velcro
25. Water hose
6510 7 8
3
11
12
13
14
4
16 17 15
1
2

English | 07
Control Panel
1. Buttons moving from left to right
• Power button
• Mode button
• Up button
• Down button
• Fan speed button
• Timer button
2. Indicator light symbols moving from
top to bottom and left to right
• Cooling mode indicator light
• Fan-only mode indicator light
• Dehumidifying mode indicator light
• Heating mode indicator light
• High fan speed indicator light
• Medium fan speed indicator light
• 3V^MHUZWLLKPUKPJH[VYSPNO[
• WiFi indicator light
• Timer indicator light
3. Digital display panel moving from top
to bottom
• Degrees celsius indicator light
• Degrees fahrenheit indicator light
Remote Control
1. Timer button
2. Swing button
3. Temperature unit change button
4. Up button
5. Fan speed button
6. Power button
7. Mode button
8. Down button
Note: Two AAA batteries included.
1
5
2
3
4
6
7
8

08 | English
Installation
Prior to and after installation adhere to
the below:
• When moving the appliance to the
chosen location ensure it is kept in an
upright position.
• Do not place or use the appliance,
power cord, or any accessories in a
bathroom, wet, or damp place.
• 7SHJL[OLHWWSPHUJLVUHÅH[HUK
dry surface. Keep it at least 50cm
away from surrounding walls and/or
objects.
• Leave the appliance in an upright
position for at least two hours prior
to first use.
Heat Exhaust Hose Installation
1. Insert the circular connector into the
heat exhaust hose connector.
2. 9V[H[L[OLJPYJ\SHYJVUULJ[VY
counterclockwise to lock it into place.
Sliding Window Sealing Board Assembly
Installation
1. Insert panel B into panel A and adjust
to the length or height of the window.
2. Open window and place the sealing
board assembly into window.
3. (KQ\Z[[VLUZ\YLHUL_HJ[Ä[HUK
secure with the provided screw.
4. Close window to lock everything into
place.
5. Attach the heat exhaust hose short
connector to the elliptical hole.
6. The sealing board assembly is now
ready for use.
Notes:
• If your window opening is smaller
than the minimum length of the
sealing board assembly trim to
desired length using a hacksaw.
• If your window opening is larger than
the maximum length of the sealing
board assembly use plywood or
ZPTPSHY[VÄSS[OLNHW
*PYJ\SHYJVUULJ[VY

,UNSPZOc
Hinged Window Sealing Fabric
Assembly Installation
1. Open window and clean frame and
casement surfaces of dust and
particles.
2. Stick the velcro tape around the
entire window frame. Never stick
to the window seal as doing so will
prohibit the window from closing fully.
3. Stick the velcro tape around the
entire window casement (inside or
outside). Check to ensure the window
can close fully.
4. Attach side A of the sealing fabric
assembly to the velcro on the window
frame working from the centre
outwards.
5. Close and open window to ensure no
fabric gets trapped.
6. Attach side B of the sealing fabric
assembly to the velcro on the window
casement working from the centre
outwards.
7. Open the window slightly and
insert the heat exhaust hose short
connector into the sealing fabric
assembly securing with the zippers
around its lip.
8. The sealing fabric assembly is now
ready for use.
Notes:
• Do not bend the heat exhaust hose in
excess of 45 degrees. It should be as
short and as straight as possible to
LUZ\YLLMÄJPLU[HPYÅV^
• Do not overstretch the heat
exhaust hose as this may affect the
HWWSPHUJLZLMÄJPLUJ`
Frame
Side A
Side B
Casement
7
4 & 6
2 &3
Hinged window sealing fabric zip

10 | English
Controls
Control Panel
Power Button
Turn the appliance on and off.
Mode Button
Select between cooling, dehumidifying,
fan-only, and heating modes.
• Cooling Mode - Perfect for cooling
a room in hot weather. Use the up
and down buttons when in cooling
mode to set the desired temperature
between 16-30°C. The appliance
will cool the room if the room
temperature goes above the set
temperature. If the room temperature
goes below the set temperature the
appliance will stop cooling the room
and the fan will remain operating at
the set fan speed.
Note: The heat exhaust hose must
be connected to allow the hot and
humid air to be discharged outside.
• Fan-Only Mode - The appliance
VWLYH[LZH[[OLZL[MHUZWLLK9VVT
temperature is displayed on the
digital display panel.
Note: The heat exhaust hose does
not have to be connected to the
appliance.
• Dehumidifying Mode - Ideal for
reducing room humidity in humid
and damp times of year. The
appliance will dehumidify the room
if the room temperature is greater
than or equal to 15°C and the fan
operates at the low fan speed. If the
room temperature decreases to less
than 15°C the appliance will stop
dehumidifying the room and the fan
VWLYH[LZH[[OLSV^MHUZWLLK9VVT
temperature is displayed on the
digital display panel.
Note: The heat exhaust hose must
be connected to allow the hot and
humid air to be discharged outside.
• Heating Mode - Perfect for heating
a room in cold weather. Use the up
and down buttons when in heating
mode to set the desired temperature
between 16-30°C. The appliance
will heat the room if the room
temperature goes below the set
temperature. If the room temperature
goes above the set temperature the
appliance will stop heating the room
and the fan will remain operating at
the set fan speed.
Note: The heat exhaust hose must
be connected to allow the cold and
humid air to be discharged outside.
Note: Temperature can only be set when in
cooling mode or heating mode.
Fan Speed Button
Select between high, medium, and low
fan speeds.
Note: Option not available in
dehumidifying mode.
Andere Handbücher für PB-AC05
2
Inhaltsverzeichnis
Sprachen:
Andere Pro Breeze Klimaanlage Handbücher

Pro Breeze
Pro Breeze PB-AC01 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC02 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC01 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC04 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC05 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC01 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC03 Bedienungsanleitung

Pro Breeze
Pro Breeze PB AC04 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC03 Bedienungsanleitung

Pro Breeze
Pro Breeze PB-AC03 Bedienungsanleitung